B-VENT GAS FIREPLACE HEA TER INSER TS RETAIN THIS MANUAL FOR FUTURE REFERENCE Suitable for installation into masonry or factor y built fi replaces P/N 775,155M Rev . D,12/2005 FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors or liquids in the vicinity of this or any other appliance.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 2 It is imperative that the control compart- ment, burners and circulating air passage ways of the appliance be kept clean. S'assurer que le brùleur et le compartiment des commandes sont propres.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 3 T able 2 shows the main burner gas orifi ce size for the elevations indicated. Model No. Orifi ce Size Elevation Feet (meters) Nat. Gas Prop. Gas EBVI25 #41 (.096") #53 (.0595") 0-4500 (0-1372) EBVI30 #37 (.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4 MAINTENANCE The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualifi ed ser vice technician. However , more frequent periodic inspections and cleanings should be performed by the homeowner .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 Small Area Paint T ouch-up The fi nish of the insert body and surround (optional) is a high-quality powdercoat.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 Maintenance T ask Accomplishing Person Procedure Inspecting/Cleaning Burner , Logs and Controls Qualifi ed Service T echnician Inspect valve and ensure it is properly operating. Check piping for leaks.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 PROCEDURE FOR REMOVING ST ANDARD GLASS DOOR ASSEMBL Y Burner Flame Appearance BURNER ADJUSTMENT Flame Appearance and Sooting Proper fl ame appearance is a fl ame which is blue at the base and becomes yellow/orange in the top of the fl ame.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 8 If the burner fl ame appearance differs greatly from what is shown in Figure 13 (see Burner Flame Appearance) , some adjustment from the factor.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 1. Place the rear log onto the two corresponding locating pins at the back of the fi rebox as shown in Figure 16 . 2 . Place the Front Right Log onto the two corresponding locating pins as shown in Figure 17 .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10 8. Place the glowing embers on the burner as shown in Figure 23 . One package of ember material has been included with this log set Y ou will not need to use the entire bag.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 T o light the burner , rotate the gas valve control knob counterclockwise to the “ON” position then turn “ON” the off/on switch mounted.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Figure 28 If original wire as supplied must be replaced, it must be replaced with T ype AWM 105°C, 18 gauge wire.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 13 Cat. No. Model Description 89L36 WTK Wall Thermostat KiT Wall Thermostat The wall thermostat kit provides temperature control for optimum comfort. Cat.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cat. No. Model Description H1503 SKS-25 Beveled Surround, Small, EBVI25 H1504 SKM-25 B eveled Surround, Medium, E B VI25 H0881 SKS-30 Beveled Surr.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 15 H I L O W TPTH TP TH P I L O T P I L O T O N it it O F F OUT OUT IN IN 6. W ait fi ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 16 INSTRUCTIONS D’ALLUMAGE – V ANNE GAZ MILLIVOL T INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 REPLACEMENT P ARTS LIST Gas Controls Item # Part/Cat. No. Description Where Used 1 67L7001 Pilot Assembly , NG/LP EBVI25 & EBVI30 2 67L6801.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS DIAGRAMS 9 15 16 17 3 4 2 12 7b O N O F F P I L O T L O H I 5b 1 8 19 18 13 20 14b 21a 21b 14a 10b 10a 7a 5a 6 18.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 TROUBLESHOOTING THE MILLIVOL T GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2003 P/N 775,155M Rev . D 12/2005 LENNOX reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
デバイスLennox Hearth EBVI25の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth EBVI25をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth EBVI25の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth EBVI25の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth EBVI25で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth EBVI25を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth EBVI25の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth EBVI25に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth EBVI25デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。