NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS P/N 850,043M REV. F 09/2008 MODELS DIRECT VENT MERIT ™ PLUS SERIES This appliance may be installed in an aftermarket perma- nently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 1 TABLE OF CONTENTS Packaging ........................................ page 2 Introduction ..................................... page 2 General Information ......................... page 2 Location .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Note: Power venting of direct vent fireplaces may result in the reduction of efficiencies by as much as ten percent. Consider this in making any venting and heating decisions in any installation application.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 2 Figure 3 *Note: 3 in. (76mm) above any horizontal/ inclined vent component for the MPLDV30 in all cases, and for the MPLDV35, MPLDV40 & MPLDV45, when the vent center line is greater than 48" (1219 mm) above the fire- place top wrapper surface.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINA TIO.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. The fireplace should be secured to the side framing members using the unit's nailing flanges - one top and bottom on each side of the fireplace front. See Figure 6. Use 8d nails or their equivalent.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Figure 8 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent T ermination V D V 3 ft.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Figure 9 Framing FIREPLACE FRAMING SPECIFICATIONS Corner Framing with Square Termination (SV4.5HT-2) A B *7 (178) 5-1/8 **12-1/8 (308) 10-1/2 ( 267 ) D Framing should be constructed of 2 x 4 or larger lumber.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 RIGHT SIDE VIEW B 17 (432) 1 (25.4) LEFT SIDE VIEW 4 3/4 (121) 2 9/32 (58) TOP VIEW 6 5/8 (168) F G FRONT VIEW 13 11/64 (335) A E D C 10 (254 mm) H 3 5/16 (100 mm) . o N l e d o MA B C D E F G H 0 3 V D L P M .
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 13 Step 3. INSTALL THE VENT SYSTEM General Information These instructions should be used as a guide- line and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Maintain a minimum 1" (25 mm) clearance to combustible materials for all vertical vent elements. Clearances for horizontal vent elements are 1" (25 mm) at the sides and 1" (25 mm) on the bottom.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 1/2” Min. (267 mm) 10 1/2” Min. (267 mm) Figure 14 Align the dimple (four places) of the upper vent section with the opening of the locking incline channel on the lower vent section. T wist vent component clockwise to engage and seal until arrow and dimple align.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Maintain a minimum 1" (25 mm) clearance to combustible materials for all vertical vent elements. Clearances for horizontal vent elements are 1" (25 mm) at the sides and 1" (25 mm) on the bottom.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Note: Install second restrictor in any run having more than 8 ft. of vertical rise. Figure 23 - Top Vent - STRAIGHT Figure 24 - Top Vent - TWO 90 DEGREE ELBOWS VERTICAL VENT FIGURES/TABLES Note: Two 45 degree elbows may be used in place of one 90 degree elbow.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Figure 25 - Top Vent - THREE ELBOWS Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required.
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Vertical Rise SV4.5E90 Elbow Horizontal / Inclined Run SV4.5 HT -2 T ermination Firestop/Spacer SV4.5L6/12/24/36/48 Vent Sections Support Bracket Spacing Every 5 ft (1.52 m) See Figure 17 on page 12 for vertical vent section support.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Horizontal terminations have been designed to perform in a wide range of weather conditions. Our terminations meet or exceed industry standards.
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. HORIZONTAL VENT FIGURES/TABLES Note: Two 45 degree elbows may be used in place of one 90 degree elbow. The same rise to run ratios, as shown in the venting figures for 90 degree elbows, must be followed if 45 degree elbows are used.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 Figure 30 - Top Vent - ONE 90 DEGREE ELBOW - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE See Table 3 as an aid in venting component selection for a particular range of exterior wall thicknesses. Square termination (SV4.
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required. This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) vertical, you are allowed 5 feet of (H) horizontal run, up to a maximum horizontal run of 20 feet.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 21 GEAR CLAMPS Adapter (SV4.5RF) Apply ONL Y MIL-PAC BLACK HIGH TEMPERA TURE SEALANT (Catalog No. 10K81) to the outside surface of both collars of the .
22 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 4. FIELD WIRING Caution: Label all wires prior to disconnec- tion when servicing controls. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation after servicing. Refer to Section A for millivolt appliances and Section B for electronic appliances.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 23 Figure 39 Step 5. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The orientation of the shut- off valve should face the front, as shown in Figure 39 . Figure 38 illustrates the method for connecting the gas supply.
24 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 40 Door Assembly Gas Line Access Panel Bottom Panel Burner Assembly Figure 42 - Figure 41 INSTALLING THE GLASS DOOR ELECTRONIC Pilot Hood Sensor Ignitor MILLIVOL T Thermocouple Hood Ignitor Rod 3/8" Min (9 mm) Thermopile Pilot Nozzels Step 6.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 25 Figure 43 Figure 44 Burner Adjustment Step 9. BURNER ADJUSTMENTS Flame Appearance and sooting Proper flame appearance is a matter of taste. Generally, most people prefer the warm glow of a yellow to orange flame.
26 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17" 14" Min. Distance T o Unprotected Side Wall 8-1/4" 45 ° Combustible Materials Allowed In Shaded Area “Safe Zone” 12" 5" Min.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 27 INSTALLATION ACCESSORIES CONTINUED d e t s i L x e l F e r u c e S s t n e n o p m o C ™ . t a C .
28 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 47 Burner Assembly Gas Valve Assembly Orifice Air Adjustment Arm In Canada: THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 29 Pressure Regulator Remove These Components Pilot Orifice Figure 51 Figure 50 Figure 52 Figure 49 Figure 48 Note: If the ignitor is damaged, a replacement kit is available, order Catalog Number 87L54.
30 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 31 NOTE: THIS PAGE INTENTIONALLY LEFT BLANK..
32 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 850,043M REV. F 09/2008 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
デバイスLennox Hearth MN04-VDLPMの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth MN04-VDLPMをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth MN04-VDLPMの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth MN04-VDLPMの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth MN04-VDLPMで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth MN04-VDLPMを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth MN04-VDLPMの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth MN04-VDLPMに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth MN04-VDLPMデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。