Lennox HearthメーカーMPDR-3328CNE-Bの使用説明書/サービス説明書
ページ先へ移動 of 42
MODELS OTL Report No. 116-F-13-4 US Portland This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
2 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS P ACKAGING The assembled vented gas fireplace heater is packaged with: • (1 set) Logs (packaged in a carton inside the firebox).
3 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injur y or property damage. Refer to this manual.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T est gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side).
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS HORIZONT AL VENT (Rear Vent.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 12 X Roof Pitch is X/12 2 FT MIN.
7 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Models Combustible Shelf He.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 9: Minimum Mantel Cl.
Pressure Relief Plates 10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Side Framing Unit Nailing Flange (No clearance to combustible framing is required .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS G H Top View (Louvered Front Model Shown) Concentric Flue: Flue 4-1/2" (114 mm); Combustion Air 7-1/2" (190 mm).
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS FIREPLACE FRAMING SPECIFIC.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Us e onl y ap pr ove d ve nt co mp on en ts (s ee Ap pr ove d V en t Co mpo ne nt s on Pa ge 2 ).
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Min. 10-1/2" (267 mm) Min. 10-1/2" (267 mm) First Vent Component Align the dimple (four places) with the opening of the locking incline channel on appliance collar .
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Framing Dimensions for Roof Pitch C D 0/12 10-1/2 in. 10-1/2 in. (267 mm) (267 mm) 6/12 10-1/2 in.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 31: Rear Vent - ONE.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T A BL E C H + H 1 Ma xim um H Ma xim um V Mi nim um fe et fe et fe et 5 (1 .
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 35 The unitized design of the Secure Vent compo- nents will engage and seal both the inner and outer pipe elements with the same procedure.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS IMPORT ANT : The vent termination is hot while in operation and for a period of time following the use of the fireplace.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS H Max im um V Min imu m fe et fe et 5 (1 .52 4) 1 ( 0. 3 05 ) 10 ( 3.0 48 ) 2 (0 .
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS T ABL E H H + H 1 Ma xim um H Ma xi mu m V M ini mum fe et f ee t f ee t 5 (1 .
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 44: T op Vent - THR.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 5" (127 mm) Radius Minimum Flexible Vent Section E.
25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 5.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Note: Remote receiver shou.
27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS B. Br ush al l jo in t s a nd co n ne cti ons wi t h t he ga s le ak tes t so lu t io n to che ck f or le a ks .
28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 9. INST ALL VOLCANIC STONE, GLOWING EMBERS AND LOGS NOTE: T urn off all electricity to the appliance before you install volcanic stone, embers and logs.
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 1 Log Number Description (.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 58 MPD-3530 LOG PLA.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Figure 59 MPD-4035 AND MPD.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Step 10.
33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS W ARNINGS • Air shutter adjustment should only be performed by a quali- fied profes sion al servic e tech- nician.
LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 64 Combustible Finished Wall Materials Min. 1" (25 mm) This area must remain clear of combustible materials.
LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS 35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
36 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Vent™ Components Cat. No. Model Description 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.
37 LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Listed Secure Flex™ Components Cat. # Model Description H1969 SF4.5HT -2 Horizontal Square T ermina- tion for flex (without flex vent) 77L87 SFKIT12S Square T erm.
38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No.
39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Burner Assembly Gas Valve Assembly Orifice Figure 67 Millivolt Appliances Step 4.
40 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Retaining Clip Ignitor Ass.
41 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS NOTES.
42 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. LENNOX HEARTH PRODUCTS • MERIT ® PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INST ALLA TION INSTRUCTIONS Lennox Hearth Products res.
デバイスLennox Hearth MPDR-3328CNE-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth MPDR-3328CNE-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth MPDR-3328CNE-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth MPDR-3328CNE-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth MPDR-3328CNE-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth MPDR-3328CNE-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth MPDR-3328CNE-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth MPDR-3328CNE-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth MPDR-3328CNE-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。