EP A Wood-Burning Fireplace P/ N 85 0,0 37 M RE V . K 05 /20 10 MONTE MODEL MONTECITO™ INST ALLA TION AND OPERA TION INSTRUCTIONS SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards: ULC-S610 and UL-127 Report No. 307-4084 EP A Cert. No.
IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R UL ES B EF OR E Y OU R F IR S T F IR E . W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food.
T ABLE OF CONTENTS Safety Rules and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment .
Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindli ng on top of the paper , criss-c rossi ng the kindling so that there are air spaces in between.
A. Negative pressure in the house - As the fire burns, air goes up the chimney . This air must be replaced through leakage into the hous e or throug h the outsi de air duct. When operating the Montecito fireplace, open a nearby window temporaril y to check if there is adequate replacement air supply .
REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in“First Fires”.They willnot normallydimin - ish the effectiveness of the refractory .
Facade Installation In sta ll the Fac ade pe r i nst ruc ti ons pr ovi ded in Fa cad e K it (o rde red se pa rat ely - se e P age 2 0 ). Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figures 10 and 11 ): A.
FRAMING DIMENSIONS Fireplace Opening Width A 36-1/4” 921 mm B 42” 1067 mm C 30-1/16” 764 mm D 13-1/2” 343 mm E 77” 1956 mm F 37-1/2” 953 mm G *24-1/2” 603 mm J 53-3/4” 1365 mm K 8” 2.
Figure 9 Insulated Chase Construction Figure 11 Floor Ceiling Wall • Must have the same firestopping resistance as adjacent wall. • Must have the same insulation as adjacent ceiling.
HOT AIR DUCTING INST ALLA TION The Montecito™ wood burning fireplace is approved for use with a Gravity kit (hot air ducting system). Gravity Kit The gravity kit is designed for double hot air outlets and includes: (See Figure 14 ). - T wo(2)telescopiclengths8”I.
Figure 17 OUTSIDE AIR KIT It is mandatory to install an outside air connec- tion to the Montecito™ wood burning fireplace. The following components are required and are included with the fireplace.
Figure 18 OUTSIDE CONNECTION Figure 19 Aluminum T ape Aluminum T ape Fireplace Connection Plastic Cover Insulation Flexible Pipe Fireplace 5. All chimney installations must include at least one support. Re- ducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands.
CHIMNEY INST ALLA TION INSTRUCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 21 ). Use aplumb-bob tolineup the centerof theholes.
Roof Down Slope Hole Size S L O P E A S H T + / H T 6 1 0 3 + S - 2 1 00 + / H T 6 0 0 0 + A C R o o f P it c h 6 ” 6 ” 6 ” 0 * 1 2 - 3 /8 ” ( 3 1 4 m m ) 1 4 - 1 /8 ” ( 3 5 9 m m ) 1 5 ” .
Figure 26 Ch im ne y 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8 ” 1 8” & 4 8 ”.
Figure 27 OFFSET CHIMNEY INST ALLA TION Chimney AC Support ACRS Starter Section Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 28 Straps Straps OF FSE T CHI MN EY IN ST ALLA TIO N WIT H W ALL P ENE TR A TIO N Note: In cold areas it is recom- mended to protect the chimney in a insulated chase.
If possible, you should choose a location where the chimney will pass throu gh the house without cutting floor or roof joists (see fireplace dimen- sions Page 9 ). Usually , no additional oor support is needed for the fireplace.
CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. ForASHT+/ HT6103+andS-2100+/ HT6000+,itmust beusedon a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset.
INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote.
Installation Accessories Description Cat./ Part No. Facades (Required - Order Separately) Montecito™ Facade Black, MFBK H4843 Montecito Facade Brushed Nickel, MFBN H4844 Montecito Facade Hammered St.
CHIMNEY - P ARTS AND COMPONENTS LISTS Firep lace Model MONTE - Approved Venti ng Compone nts manufa ctured by Security Chimneys International only . • 6” diameter chimney - AC (air cooled), Secure T emp™ ASHT+ (or Nova T emp™ HT6103+) and Secure T emp S-2100+ (or Nova T emp HT6000+).
CHIMNEY - P ARTS AND COMPONENTS LISTS (AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior * AC Ch i m ne y is N O T re co m m en d .
CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 17”(324mm)measuredfromthereplaceside Ceiling: 6’.
Printed in Canada © 2006 Lennox Hearth Products P/N 850,037M REV . K 05/2010 24 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number _____.
デバイスLennox Hearth ULC-S610の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth ULC-S610をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth ULC-S610の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth ULC-S610の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth ULC-S610で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth ULC-S610を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth ULC-S610の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth ULC-S610に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth ULC-S610デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。