Page 1 of 2 5" Aperture Basic White Reflector Reflector Trim


Features 1. Reflector: Hydroformed aluminum, .040" thick, (18 ga.); non-yellowing, scratch resistant Perma White Finish, 88% reflectance; white trim flange. 2. Frame-In Kit: (1002P1 standard frame shown). Other frames listed above and shown on the right. See Frame-In Kit specification sheets for more details.
Job Name:
Cat. No.:
Lamp(s):
Options & Accessories Medium-Base PAR30 1968 - For use w/short neck PAR30 lamps Socket Extender:
Labels UL (Suitable for Damp Locations); I.B.E.W.

Page 2 of 2 5" Aperture Basic White Reflector Reflector Trim

Use quick calculator chart to determine the spacing of 100 Watt BR30 FL units for a desired level of illumination. Conversion Factor: 75W A19, F.C. x 0.85. 1 Lt 13W Quad Tube, F.C. x 0.6. Spacing Ratio = 0.9

Certified Test Report NO. 0275FR Computed by lsi program **Test Lite**
REcessed Open Lytecaster downlight 5 1/16" DIA. Aperture, basic white reflector one 75W BR30 Flood Lamp. Lumen rating = 770LMS
ANGLE MEAN CP LUMENS 0 447 5 438 42 10 420 15 386 108 20 339 25 293 136 30 254 35 225 142 40 200 45 164 122 50 104 55 69 67 60 56 65 45 44 70 33 75 21 23 80 11 85 5 6 90 1
Zonal lumens and percentages
ZONE LUMENS % LAMPS % LUMINAIRE 0–30 286 37.20 41.49 0–40 428 55.63 62.04 0–60 617 80.15 89.40 0–90 690 89.66 100.00 40–90 262 34.03 3796.00 60–90 73 9.51 10.60 90–180 0 .00 .00 0–180 690 89.66 100.00
Coefficients of Utilization
20% Floor cavity reflectance
Conversion Factor: 75W A19, C.U. x 0.5. 1 Lt. 13W Quad Tube, C.U. x 0.5.
To convert lighting data for a lower wattage incandescent lamp of the same type, multiply the footcandle (or candlepower) values by the ratio of the lumens of the two lamps. The coefficients of utilization remain the same.
Candlepower summary