Page of 2 6 ¾" Aperture Horizontal Open, Compact Fluorescent, Performance Series, Reflector Trim

Complete Fixture consists of Frame-In Kit and Reflector Trim. Select each separately.
Features 1. Reflector: Formed aluminum. Matte White flange. 2. Finishes: CL = Specular Clear (Iridescent Free coating) CD = Clear Diffuse WH = Matte White Paint 3. Performance Data: 60° Cutoff angle. See attached photometric reports for distribution and efficiency data. Go to www.lightolier.com for .IES files.
Labels cULus Listed. Suitable for Damp Locations. I.B.E.W.


Page of 2 6 ¾" Aperture Horizontal Open, Compact Fluorescent, Performance Series, Reflector Trim
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
COEFFICIENTS OF UTILIZATION Ceiling 80% 70% 50% 30% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
CANDLEPOWER SUMMARY Angle 0˚ CP 90˚ CP 0 720 720 5 722 725 10 689 697 15 641 633 20 626 558 25 621 535 30 573 569 35 492 483 40 416 399 45 383 336 50 366 321 55 318 306 60 42 44 65 9 9 70 5 6 75 4 4 80 3 3 85 2 3 90 2 3
ZONAL LUMENS AND PERCENTAGES Zone Lumens %Lamp %Fixt
Zone Lumens 0-10 68.47
0-30 516.68 23.5 38 0-40 827.14 37.6 60.9 0-60 1337.28 60.8 98.5 0-90 1357.97 61.7 100 90-120 90-150 90-180-180 1357.97 61.7 100
10-20 181.71
0 73 72 72 69 69 66 66 62 1 69 67 65 63 65 62 63 60 61 58 55 2 64 60 57 54 59 54 57 52 55 51 49 3 59 54 50 47 53 47 52 46 50 45 43 4 55 49 44 41 48 41 47 40 45 40 38 5 51 44 40 36 44 36 42 36 41 35 34 6 48 40 36 32 40 32 39 32 38 34 31 7 44 37 32 29 36 29 35 28 35 31 28 8 41 34 29 26 33 26 33 26 32 28 26 9 39 31 27 23 31 23 30 23 30 26 23 10 36 29 24 21 29 21 28 21 27 24 21 Determined In Accordance With Current IES Published Procedures
20-30 266.5
30-40 310.46
40-50 281.1
50-60 229.04
60-70 13.53
70-80 4.17
80-90 2.98
** Efficiency = 61.7% **
Luminaire Input Watts = 33.0
SC = 1.1 1 = 90˚ 2 = 0˚ CERTIFIED TEST REPORT NO. 3166FR COMPUTED BY LSI PROGRAM **TEST-LITE**