Lytecaster ® Recessed Downlighting 1185

Page 1 of 2 6 3/4" Aperture Basic White Wall Washer Reflector Trim

Lightolier 1185 — Lytecaster ® Recessed Downlighting 1185 diagram (page 1)
図 1 · Lytecaster ® Recessed Downlighting 1185

9 1/4” 7 1/8” 1185/1103R 0 ™ Non-IC Remodeler Ring

1185/1100 DEEP IC Series Incandescent Insulated Ceiling

Lightolier 1185 — 1185/1100 DEEP IC Series Incandescent Insulated Ceiling diagram (page 1)
図 2 · 1185/1100 DEEP IC Series Incandescent Insulated Ceil…

7 1/2”

1185/1104IC/N 0 ™ Convertible IC/Non-IC

Reflector TrimFrame-In Kit — See Individual Frame-In Kit Specification Sheets 1185 Perma WhiteIncandescentFluorescent Frame-In KitInstallation TypeLampingHeightFrame-In KitInstallation TypeLampingHeight 1102P1 1103RNon-IC Non-IC Remodeler100W A197 1/8" 7 1/8"1104F13 SeriesIC(1) Quad/Triple 13W (GX24q-1)7 1/2" 1104F18 SeriesIC(1) Quad/Triple 18W (GX24q-2)7 1/2" 1100IC 1100AICM 1104ICX/NIC AirSeal® IC AirSeal® IC52W A197 5/16" 7 5/16" 7 1/4"1104F26 SeriesIC(1) Triple 26W (GX24q-3)7 1/2" 1100FTU SeriesNon-IC(1) Triple 26/32W (GX24q-3)6 7/8" 1100AICMFTAirSeal® IC(1) Triple 26/32W (GX24q-3)6 7/8" 1910XFH1Conversion Kit(1) Quad 13W (GX23-2)6 7/8" 1100DICM 1100DAICM 1104IC/N 1104ICRDeep IC Deep AirSeal® IC AirSeal® IC IC Remodeler40W A199 1/4" 9 1/4" 7 1/2" 7 1/2"1910XDH1Conversion Kit(2) Quad 13W (GX23-2)6 7/8" 1104IC/N 1104ICRNon-IC Non-IC Remodeler60W A197 1/2" 7 1/2"

Features 1. Deep Reflector: Hydroformed aluminum, .040" thick (18 ga.); Perma White® finish with 88% reflectance; white trim flange. Provides smooth wash of light over wall surface without scallops or shadows. 2. Aperture Plate: Molded high-heat polymer, white finish. 3. Frame-In Kit: (1102P1 standard frame shown). Other frames listed above and shown on the right. See Frame-In Kit specification sheets for more details.

US Patent Numbers: 5,045,985 Other US & Foreign Patents Pending.

Lightolier 1185 — 7 1/2” diagram (page 1)
図 3

Labels UL (Suitable for Damp Locations), I.B.E.W.

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • I1007
Page 2 of the Lightolier 1185 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Lytecaster ® Recessed Downlighting 1185

Page of 2 6 3/4" Aperture Basic White Wall Washer Reflector Trim

Lightolier 1185 — Lytecaster ® Recessed Downlighting 1185 diagram (page 2)
図 4 · Lytecaster ® Recessed Downlighting 1185

lighting data Example: Multiple units with 100W A19lamps, located 2’ from wall and 2’ on center, illumination on the wall 3’ down from the ceiling of 35 f.c. beneath and 35 f.c. between the fixtures.

footcandles on wall from multiple units

Lightolier 1185 — footcandles on wall from multiple units diagram (page 2)
図 5 · footcandles on wall from multiple units
Lightolier 1185 — footcandles on wall from multiple units diagram (page 2)
図 6 · footcandles on wall from multiple units

1 39 36 39 29 19 29 2 49 47 49 33 30 33 3 35 35 35 23 25 23 4 29 26 29 19 18 19 5 16 18 16 13 12 13 6 12 11 12 4 4 4 7 8 8 8 6 6 6 8 6 6 6 9 7 8 7 6 6 6

1 15 14 15 12 8 12 2 20 20 20 15 13 15 3 15 15 15 11 10 11 4 10 10 10 7 7 7 5 6 6 6 5 5 5 6 4 4 4 3 3 3 7 3 3 3 2 2 2 8 2 9 2 2 2 1 1 1

Lightolier 1185 — footcandles on wall from multiple units diagram (page 2)
図 7 · footcandles on wall from multiple units
Lightolier 1185 — footcandles on wall from multiple units diagram (page 2)
図 8 · footcandles on wall from multiple units

1 14 12 14 10 10 10 2 22 20 22 16 14 16 3 23 23 23 18 16 18 4 19 19 19 16 14 16 5 16 15 16 13 12 13 6 12 11 12 10 8 10 7 9 10 9 8 6 8 6 6 6 9 8 8 8 5 6 5

1 23 21 23 18 12 18 2 29 29 29 21 18 21 3 22 22 22 15 15 15 4 14 15 14 10 10 10 5 10 10 10 7 7 7 6 6 7 6 5 5 5 7 5 5 5 4 4 4 8 3 9 2

Footcandle values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than those shown, use maximum of 1 of 1 spacing (distance between fixtures not more than distance to wall) for best result. To convert lighting data for a lower wattage incandescent lamp of the same type, multiply the footcandle values by the ratio of the lumens of the two lamps.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • I1007
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 1185について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 1185に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 1185 取扱説明書(PDF)

2 ページ·164 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…