Page 1 of 2 3 3/4" Aperture Deep Anodized Wall Washer Reflector Trim


Features 1. Deep Reflector: Hydroformed aluminum, .040 thick (18 ga.); specular clear, specular gold or clear diffuse finish; matte white flange. Depth provides 34°shielding angle. 2. Frame-In Kit: (2002P1 standard frame shown). Other frames listed above and shown on the right. See Frame-In Kit specification sheets for more details.
Labels UL (Suitable for Damp Locations), I.B.E.W.
Job Name:
Cat. No.:
Lamp(s):
5 1/2"

Page 2 of 2 3 3/4" Aperture Deep Anodized Wall Washer Reflector Trim
12 f.c. 12 f.c.
lighting data Example: With clear Alzak® and 60W BT15 units, located 18" from wall and 2' on center, (matching downlights 2' on center), the illumination on the wall 3' down from the ceiling is 12 f.c. beneath and 12 f.c. between fixtures.
units 18 inches from wall 18" 24" 30”
distance from ceiling, ft.
1 2 3 4 5 6 7 8 9
9 7 9 20 20 20 16 16 16 11 11 11 8 8 8 5 5 5 4 4 4 3 3 3 2 2 2
8 4 8 15 15 15 12 12 12 9 9 9 6 6 6 4 4 4 3 3 3 2
8 2 8 13 11 13 10 10 10 7 7 7 5 5 5 4 4 4 3 3 3 2
Footcandle values are averaged and rounded off and are based on a minimum of five units.

Report 1266FR Efficiency = 33.6%
Downlight Spacing Ratio = 1.2
% effective ceiling cavity reflectance
1 .37 .37 .36 .37 .36 .35 .35 .35 .34 .34 .34 .33 .33 .33 .32 2 .35 .33 .32 .34 .33 .32 .33 .32 .31 .32 .31 .30 3 .32 .31 .29 .32 .30 .29 .31 .30 .29 .30 .29 .28 4 .30 .28 .27 .30 .28 .27 .29 .27 .26 .28 .27 .26 .28 .27 .26 5 .28 .26 .24 .28 .26 .24 .27 .25 .24 .26 .25 .24 .26 .25 .24 6 .26 .24 .22 .26 .24 .22 .25 .23 .22 .25 .23 .22 .24 .23 .22 7 .24 .22 .20 .24 .22 .20 .23 .21 .20 .23 .21 .20 .22 .21 .20 8 .22 .20 .19 .22 .20 .18 .21 .20 .18 .21 .19 .18 .21 .19 .18 9 .20 .18 .17 .20 .18 .17 .20 .18 .17 .20 .18 .17 .19 .18 .17 10 .19 .17 .15 .19 .17 .15 .18 .17 .15 .18 .16 .18 .18 .16 .15
.32 .29 .27 .25 .23 .21 .19 .18 .16 .15
20% Floor cavity reflectance
To convert lighting data for a lower wattage incandescent lamp of the same type, multiply the footcandle (or candlepower) values by the ratio of the lumens of the two lamps.The coefficients of utilization remain the same.
2 18" · Down Wall · Room cavity ratio