Page 1 of 2 2'x2' SURFACE BOX FLUORESCENT, 1 1/2" DEEP, 36 CELL PARABOLIC LOUVER 2-6"U LAMP T8/T12, 3-1.6U LAMP T8 OR TT5


24" (610mm)
3" (76mm)
7/8" K.O.

9/32" mounting hole
1-1/4" (32mm)
36 Cell
7/8" Dia. K.O. within 1-7/8" dia. K.O.
3/16" x 5/8" K.O.
9-1/2" (241mm)
24" (610mm)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2'x2' SURFACE BOX FLUORESCENT, 1 1/2" DEEP, 36 CELL PARABOLIC LOUVER 2-6"U LAMP T8/T12, 3-1.6U LAMP T8 OR TT5

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 64 62 60 58 57 56 56 55 54 2 59 56 52 52 50 48 51 49 47 3 55 50 46 47 44 41 46 43 41 4 50 44 40 42 39 36 41 38 35 5 47 40 35 38 34 31 37 34 31 6 43 36 31 35 31 28 34 30 27 7 40 33 28 31 27 25 31 27 24 8 37 30 25 29 25 22 28 24 22 9 35 27 23 26 23 20 26 22 20 10 33 25 21 24 21 18 24 20 18 visual comfort probability

2850 31W/U6/T8
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 82 76 71 77 79 71 64 71 20 30 82 78 74 72 79 73 68 65 20 40 82 78 77 75 79 74 73 68 20 60 85 78 77 75 83 74 71 68 30 20 85 80 72 74 81 76 67 70 30 30 85 81 75 70 81 78 70 65 30 40 85 81 77 73 81 78 72 68 30 60 87 81 77 73 84 78 72 68 30 80 87 81 76 74 64 78 72 68 40 20 85 80 76 74 81 76 71 72 40 30 85 81 78 71 81 78 74 67 40 40 85 81 79 74 81 78 75 70 40 60 87 81 79 74 83 78 76 70 40 80 87 81 79 74 83 78 76 70 40 100 87 80 79 74 83 78 76 70 60 30 85 81 79 74 81 78 74 70 60 40 86 81 79 76 81 78 75 73 60 60 87 80 80 76 83 78 76 73 60 80 87 80 80 76 83 78 76 73 60 100 87 81 80 76 83 78 76 73 100 40 86 80 80 76 81 78 76 73 100 60 87 80 80 76 83 78 76 73 100 80 87 80 80 77 83 78 76 73 100 100 87 81 80 77 83 78 76 74
ML
B
S
S
FIXTURE
NUMBER OF
WHITE REFLECTOR
BALLAST TYPE: LE=Magnetic (T12) OC=Magnetic (T8) SS=Electronic (T12) S3=1-3 Lamp Elec. (T12) SO=Electronic (T8) O3=1-3 Lamp Elec. (T8) DIM=Dimming (T12) PS=LOL Power Spec
WIDTH
CELLS
1 1/2" Deep Precision Contoured Pre-
U1.6 T8 or TT5 U6=6" UT8
semi-specular (standard) P=Low-iridescence
Electronic T8 Ballast Only)
Ballast PB=LOL Power
*Consult factory for availability of louver finishes.
OPTIONS & ACCESSORIES FUSING: Internal fast-blow fusing. SUFFIX: GLR.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, welded for rigidity. LOUVER: pre-anodized aluminum (Coilzak® or equal). FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W., UL, ULc Listed.
Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. LOW DENSITY CEILINGS: DSM STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface (four per fixture is recommended). Catalog Number ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .62. To prevent glare the VCP shall be not less than 83 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 328 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 69.3°.