JA
Lightolier logo
公式取扱説明書

Lightolier 404722XU3

2 ページ·424 KB·インテリア家具・調度品·PDF·EN
Lightolier 404722XU3
目次 22セクション Specification Decorative Pendalyte ™ 404722XU3 · Page 1 of 2 12" 2 Lamp Pendant · Suspension Details · Deco Kit Available (see spec sheet 412DK) · … 表示非表示
Page 1 of the Lightolier 404722XU3 user manual — Lightolier is a Philips group brand
1ページ · クリックして拡大
1ページ

Specification Decorative Pendalyte ™ 404722XU3

Page 1 of 2 12" 2 Lamp Pendant

Suspension Details

Lightolier 404722XU3 — Suspension Details diagram (page 1)
図 1 · Suspension Details
Lightolier 404722XU3 — Suspension Details diagram (page 1)
図 2 · Suspension Details

2x26W Triple Tube 2x32W Triple Tube 2x42W Triple Tube

† Larger dimensions apply to Dimming Fixtures.

Reflector/RefractorPower Head Cat. No.Cat. No.LampWattsVoltsOptions - suffix to be added to Cat.No. (i.e.404722XU3) 40421 40422Anodized Reflector Semi Specular Acrylic Refractor404722XCFL Triple Tube2x26/32/42120/277U3, U3E3, U2MX1,U2MX2, U4MX1, U4MX2
Reflector/Refractor OptionsSuspensionOptional Extension Kits Cat. No DescriptionUse WithCat No.ColorDescriptionCat No.ColorDescription 421G Indust 422A Flat A 404TRM12 12" Tri 412GRL Cross 412WHL Cross 422G Industrrex® Glass Lens crylic Lens m Ring Blade Louver Gray Blade Louver White ex Glass Lens40421 40422 40422/40421 40421 40421 40422404SKG 404S36 404S60 404S120 404GLS 4912CTCGRGrayCable/Straight Cord 120" Length 36" Length, 5/8" Stem 60" Length, 5/8" Stem 120" Length, 5/8" Stem Track Mounting Kit Direct to Ceiling Kit for Standard 12" Pendalytes404EXT300*Gray25' Ext. Cable Cord Kit * Use along with standard suspension kit.

Features 1. Refractor/Reflector: Injection Molded Acrylic, UV Stabilized or Semi-specular High Purity Anodized Aluminum, 16 gauge iridescence-free. 2. Power Head Housing: Two-piece extruded aluminum. Removable door allows for ease of installation and servicing. Dark Gray textured powder coat finish. 3. Suspension: Cable/Cord: 1/16" Stainless Steel/SJT 18-3, Gray. Cable/Coiled Cord: 1/16" Stainless Steel/SJT 18-3, Gray. Gray Canopy. Stem: 5/8" Steel tubing and canopy, with 35 degree swivel hanger. Gray Finish. 4. Shielding Options: Clear Acrylic Lens, Industrex® Glass Lens or Louver.

2x26 Watt2x32 Watt2x42 Watt Voltage Total Input Watts Max. Line Current (Amps120 ‑55 ) .46277 ‑55 .21120 ‑68 .57277 ‑68 .25120 ‑93 .78277 ‑93 .33

Power Factor > 0.98, Ballast Factor 0.98, THD < 10%, Minimum Starting Temperature 0°F.

Labels cULus listed suitable for damp locations.

Deco Kit Available (see spec sheet 412DK)

Lamping (by others) Compact Fluorescent:

® is a registered trademark of AFG Industries, Inc.

Lightolier 404722XU3 — Deco Kit Available (see spec sheet 412DK) diagram (page 1)
図 3 · Deco Kit Available (see spec sheet 412DK)

| General Electric | Osram/Sylvania | Philips

(2) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp | F26TBX/*/A/4P | CF26DT/E/IN/* | PL-T26W/*/4P

(2) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp | F32TBX/*/A/4P | CF32DT/E/IN/* | PL-T32W/*/4P

(2) 42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp | F42TBX/*/A/4P | CF42DT/E/IN/* | PL-T42W/*/4P *Manufacturers’ color temperature designation. Electrical Lampholders: Compact Fluorescent: 4-Pin, 26/32 watt base: GX24q-3;

  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • I0109
42 watt baseGX24q-4

Lightolier is a Philips group brand

Industrex

Page 2 of the Lightolier 404722XU3 user manual — DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
2ページ · クリックして拡大
2ページ

Specification Decorative Pendalyte ™ 404722XU3

Page 2 of 2 12" 2 Lamp Pendant Application Data

Application Data

Multiple Units (2x26W Triple Tube ) with cross blade louver Spacing Height Initial Watts on to Lighted Foot- Per Center Plane candles Sq. Ft. 6’ 6’ 75 1.50 12’ 68 8’ 6’ 42 0.86 12’ 38 10’ 6’ 27 0.55 12’ 24

Multiple Units (2x32W Triple Tube, CFL) Spacing Height Initial Watts on to Lighted Foot- Per Center Plane candles Sq. Ft. 6’ 6’ 62 1.00 12’ 53 8’ 6’ 35 0.56 12’ 30 10’ 6’ 22 0.36 12’ 19

Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances. Height is from bottom of fixture to lighted plane.

Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflectances. Height is from bottom of fixture to lighted plane.

Illuminance (FC) Multipliers For Compact Fluorescent:

Illuminance (FC) Multipliers For Compact Fluorescent:

32 Watt = 1.3 42 Watt = 1.8

26 Watt = 0.7 42 Watt = 1.3

Spacing Ratio = 1.5 2x26W Triple Tube CFL

Spacing Ratio = 3.3 2x32W Triple Tube CFL

Lightolier 404722XU3 — Illuminance (FC) Multipliers For Compact Fluorescent: diagram (page 2)
図 4 · Illuminance (FC) Multipliers For Compact Fluorescent…

LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422

Lightolier 404722XU3 — LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422 diagram (page 2)
図 5

CERTIFIED TEST REPORT NO. 0807FR COMPUTED BY LSI PROGRAM **TEST-LITE** LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/404L12

12 1/2" DIA. REFRACTOR WITH PLASTIC LENS 2-32W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 2400 LMS MOTOROLA BALLAST CAT.M2CF26/32/42

12 1/2" DIA. CLEAR ANODIZED REFLECTOR WITH WHITE CROSS BLADE 2-26W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 1800 LMS. ESI BALLAST CAT.#ESI 2/1-CFQ-26UNV, 120 VAC

Lightolier 404722XU3 — LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422 diagram (page 2)
図 6
Lightolier 404722XU3 — LIGHTOLIER DUAL COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4047233/40422 diagram (page 2)
図 7

0 297 5 324 32 10 387 15 469 133 20 541 25 605 280 30 667 35 725 451 40 752 45 726 553 50 650 55 547 490 60 440 65 343 342 70 250 75 187 217 80 196 85 201 218 90 198

95 210 226 100 209 105 208 221 110 210 115 204 201 120 189 125 170 153 130 148 135 122 95 140 95 145 67 43 150 42 155 26 14 160 19 165 17 5 170 15 175 12 2 180 11

0 813 5 898 86 10 976 15 936 266 20 907 25 905 416 30 874 35 831 522 40 789 45 722 552 50 620 55 479 423 60 308 65 156 177 70 95 75 66 70 80 39 85 15 20 90 1

0-30 443 9.25 12.10 0-40 894 18.63 24.39 0-60 1936 40.35 52.80 0-90 2712 56.51 73.96 40-90 1818 37.88 49.58 60-90 776 16.17 21.16 90-180 954 19.89 26.04 0-180 3667 76.41 100.00

0-30 767 21.31 30.30 0-40 1289 35.82 50.92 0-60 2265 62.91 89.44 0-90 2532 70.34 100.00 40-90 1242 34.52 49.08 60-90 267 7.43 10.56 90-180 0 .00 .00 0-180 2532 70.34 100.00

** EFFICIENCY = 76.4% **

Coefficients Of Utilization 2x32W Triple Tube CFL

** EFFICIENCY = 70.3% **

8070503010 50 30 1050 30 1050 30 1050 30 1050 30 10 1 2 3 4 5 6 7 8 9 10.73 .70 .67 .64 .58 .54 .55 .49 .44 .49 .42 .37 .43 .36 .31 .38 .31 .26 . 33 .27 .22 .30 .23 .19 27 .20 .16 .24 .18 .32% .70 .67 .63 .60 .56 .51 .53 .47 .42 .47 .41 .36 .41 .35 .30 .36 .30 .25 .32 .26 .21 .28 .22 .18 .25 .19 .15 .23 .17 .13%wall reflection.51 .49 .48 .44 .42 .40 .39 .36 .33 .34 .31 .28 .30 .27 .24 .27 .23 20 .23 .20 .17 .21 .17 .14 .19 .15 .12 .17 .13 .10 .63 .60 .58 .55 .51 .47 .48 .43 .39 .42 .37 .33 .37 .32 .28 .33 .27 .23 .29 .23 .20 .26 .20 .17 .23 .18 .14 .21 .16 .12

Coefficients Of Utilization 2-26W Triple Tube CFL

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80 70 50 30 10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1 .75 .73 .71 .74 .72 .70 .71 .69 .68 .68 .67 .65 .66 .65 .64 .62 2 .68 .64 .61 .67 .63 .60 .64 .61 .59 .62 .60 .57 .60 .58 .56 .55 3 .61 .56 .52 .60 .55 .52 .58 .54 .51 .56 .53 .50 .54 .52 .49 .48 4 .55 .50 .46 .54 .49 .45 .52 .48 .45 .51 .47 .44 .49 .46 .44 .42 5 .50 .44 .40 .49 .43 .40 .47 .43 .39 .46 .42 .39 .45 .41 .38 .37 6 .44 .39 .35 .44 .38 .35 .43 .38 .34 .41 .37 .34 .40 .37 .34 .32 7 .40 .34 .30 .39 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28 8 .36 .30 .26 .35 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .25 9 .33 .27 .23 .32 .27 .23 .31 .26 .23 .31 .26 .23 .30 .26 .23 .21 10 .29 .24 .38 .29 .24 .20 .28 .24 .20 .28 .23 .20 .27 .23 .20 .19

ROOM CAVITY RATIO

20% Floor cavity reflectance

Job Information Type:

  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • I0109

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Lightolier is a Philips group brand

room cavity ratio

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 404722XU3について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 404722XU3に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 404722XU3 取扱説明書(PDF)

2 ページ·424 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…