JA
Lightolier logo
公式取扱説明書

Lightolier 406

3 ページ·57 KB·インテリア家具・調度品·PDF·EN
Lightolier 406
目次 22セクション 8292WE 0400 Decorative Performance Pendalyte 406 · Page 1 of 3 6.5” Compact Fluorescent/Incandescent · ( ) Denotes dimensions in mm · Ordering Information Power Head and Suspension: Titanium Finish · … 表示非表示
Page 1 of the Lightolier 406 user manual — (1) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
1ページ · クリックして拡大
1ページ

8292WE 0400 Decorative Performance Pendalyte 406

Page 1 of 3 6.5” Compact Fluorescent/Incandescent

150W, A-21 26, 32W, Triple Tube

6 7/8" (175) Reflector

( ) Denotes dimensions in mm

7 1/8" (181) Glass Diffuser

Ordering Information Power Head and Suspension: Titanium Finish

LampWattsVolts CFL Triple Tube Incandescent A2126/32 150120/277 120

Reflector/Glass

Catalog No. Description

416SR Satin Aluminum Reflector 416WH White Glass 416BL Cobalt Blue Glass 416AB Amber Glass

Features 1. Reflector System: Reflector: High purity, 16 gauge aluminum. Exterior satined and anodized. Interior low iridescent comfort clear anodized. Glass Diffusers: Pressed colored glass with soft etched exterior and matte white interior fritt. 2. Power Head Housing: One-piece extruded aluminum. 3. Suspension: Power Cord, SJT/18-3 (incandescent), SJT/18-5 (Compact Fluorescent) black finish. Canopy, 20 gage, .036 CRS, titanium finish. Can be field shortened.

120277120 282836 .25.11.30 1.021.021.00

THD<10%, Minimum Starting Temperature: 0°F Power Factor >0.98

Labels cULus listed suitable for damp locations.

Lamping (by others) Incandescant150W, A-21 Compact Fluorescent : Universal for 4-Pin, 26/32 watt, base: GX24q-3

Job Information Type:

General Electric Osram/Sylvainia Philips

Job Name:

Cat. No.:

(1) 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P

(1) 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P

Lamp(s):

* Manufacturers' color temperature designation.

Electrical Lampholders: Incandescent: Medium Based, Porcelain, Nickel-Plated Screw Shell Compact Fluorescent: 4-pin, 26/32 watt base: GX24Q-3 Ballast: Fluorescent: Electronic

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC
  • C0605
Show 10 more labels / short text on this page
7 1/4" (184) · 5 1/2" (140) · 3/4" (19) · 2 1/2" (51) · Incandescent Canopy · 96" (2438) · Compact Fluorescent Canopy · 11 1/4" (286) · Glass Diffuser · Reflector
Page 2 of the Lightolier 406 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Decorative Performance Pendalyte 406

Page 2 of 3 6.5” Compact Fluorescent/Incandescent

Satin Aluminum Reflector Catalog No. 406U2 / 416SR, 32W CFL, 2400 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

Ceiling 80% 70% 50% 30%

ANGLE MEAN CP LMS 0 576 5 587 56 10 605 15 612 172 20 605 25 594 271 30 553 35 489 306 40 416 45 342 264 50 263 55 181 162 60 98 65 37 46 70 14 75 6 7 80 1 85 0 0 90 0

ZONE LUMENS % LAMP %LUMINAIRE 0-30 500 20.84 38.92 0-40 806 33.58 62.72 0-60 1231 51.32 95.84 0-90 1285 53.55 100.00 40-90 479 19.96 37.28 60-90 53 2.23 4.16 90-180 0 .00 .00 0-180 1285 53.55 100.00

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .64 .60 .58 .57 .56 .57 .54 .51 .49 .53 .49 .46 .43 .50 .45 .41 .39 .46 .41 .37 .34 .43 .37 .33 .31 .40 .34 .30 .27 .37 .31 .27 .24 .34 .28 .24 .21 .32 .26 .22 .19.62 .62 .57 .55 .53 .48 .48 .43 .44 .38 .40 .34 .37 .30 .33 .27 .30 .24 .28 .21 .25 .19.59 .59 .55 .53 .51 .47 .47 .42 .43 .38 .39 .34 .36 .30 .33 .27 .30 .24 .27 .21 .25 .19.57 .57 .53 .51 .49 .46 .45 .41 .42 .37 .38 .33 .35 .30 .32 .26 .29 .24 .27 .21 .24 .19

RCR

** EFFICIENCY = 53.5% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 33.0

Report No. 2597FR SC = 1.3

White Glass Reflector Catalog No. 406U2 / 416WH, 32W CFL, 2400 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 349 90 100 5 349 33 95 105 114 10 347 100 109 15 336 95 105 113 119 20 320 110 116 25 295 135 115 118 117 30 260 120 120 35 219 138 125 120 107 40 178 130 119 45 142 112 135 118 91 50 118 140 116 55 106 96 145 112 70 60 98 150 108 65 95 95 155 103 47 70 94 160 93 75 95 101 165 74 20 80 96 170 46 85 95 105 175 20 2 90 100 180 9

ZONE LUMENS % LAMP %LUMINAIRE 0-30 263 10.98 16.47 0-40 401 16.71 25.06 0-60 609 25.39 38.08 0-90 910 37.94 56.90 40-90 509 21.23 31.83 60-90 301 12.55 18.81 90-180 689 28.74 43.10 0-180 1600 66.68 100.00

Ceiling 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .73 .65 .62 .58 .56 .59 .54 .49 .45 .54 .47 .42 .38 .50 .42 .37 .33 .46 .38 .32 .28 .42 .34 .29 .25 .39 .31 .25 .22 .36 .28 .23 .19 .34 .26 .21 .17 .32 .24 .19 .15.68 .68 .57 .52 .50 .46 .44 .36 .40 .31 .35 .27 .32 .23 .29 .21 .26 .18 .24 .16 .22 .15.58 .58 .49 .45 .43 .37 .38 .32 .34 .27 .31 .24 .28 .21 .25 .19 .23 .17 .21 .15 .20 .13.50 .50 .42 .49 .37 .32 .32 .27 .29 .24 .27 .21 .24 .19 .22 .16 .20 .15 .19 .13 .17 .12

RCR

** EFFICIENCY = 66.7% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 31.0

Report No. 2636FR SC = 1.1

Amber Glass Reflector Catalog No. 406U2 / 416AB, 32W CFL, 2400 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 396 90 7 5 395 38 95 7 8 10 395 100 8 15 381 108 105 8 9 20 363 110 9 25 334 153 115 9 9 30 293 120 9 35 242 152 125 9 8 40 189 130 9 45 141 111 135 9 7 50 104 140 8 55 80 73 145 8 5 60 61 150 7 65 47 48 155 7 3 70 36 160 6 75 27 29 165 5 1 80 19 170 3 85 12 14 175 1 0 90 7 180 0

ZONE LUMENS % LAMP %LUMINAIRE 0-30 298 12.44 38.54 0-40 450 18.76 58.14 0-60 634 26.44 81.94 0-90 724 30.19 93.56 40-90 274 11.43 35.42 60-90 90 3.75 11.63 90-180 49 2.08 6.44 0-180 774 32.27 100.00

Ceiling 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .38 .35 .34 .33 .32 .33 .31 .29 .28 .31 .28 .26 .24 .29 .26 .24 .22 .27 .24 .21 .19 .25 .22 .19 .18 .23 .20 .17 .16 .22 .18 .16 .14 .20 .17 .14 .13 .19 .15 .13 .12.37 .37 .33 .31 .30 .27 .27 .24 .25 .22 .23 .19 .21 .17 .19 .16 .18 .14 .16 .13 .15 .12.35 .35 .32 .30 .29 .26 .26 .23 .24 .21 .22 .19 .20 .17 .19 .15 .17 .14 .16 .13 .15 .11.33 .33 .30 .29 .28 .26 .25 .23 .23 .21 .21 .18 .20 .17 .18 .15 .17 .14 .15 .12 .14 .11

RCR

** EFFICIENCY = 32.3% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 31.0

Report No. 2635FR SC = 1.1

have the same Photometrics.

For 26W Lamp, multiply calculated Footcandle values by .75

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC
  • C0605
Show 9 more labels / short text on this page
60° · Room Cavity Ratio · 30° · 60° · Room Cavity Ratio · 30° · 60° · Room Cavity Ratio · 30°
Page 3 of the Lightolier 406 user manual — Job Information Type:
3ページ · クリックして拡大
3ページ

Decorative Performance Pendalyte 406

Page 3 of 3 6.5” Compact Fluorescent/Incandescent

Satin Aluminum Reflector Catalog No. 406151 / 416SR, 150W A-20, 2780 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

Ceiling 80% 70% 50% 30%

ANGLE MEAN CP LMS 0 628 5 634 61 10 650 15 676 194 20 734 25 796 362 30 801 35 750 465 40 659 45 543 416 50 403 55 237 220 60 101 65 39 49 70 19 75 9 10 80 3 85 0 1 90 0

ZONE LUMENS % LAMP %LUMINAIRE 0-30 616 22.18 34.70 0-40 1081 38.89 60.85 0-60 1716 61.75 96.61 0-90 1776 63.92 100.00 40-90 695 25.02 39.15 60-90 60 2.17 3.39 90-180 0 .00 .00 0-180 1776 63.92 100.00

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .76 .76. .76 .76 .72 .70 .68 .66 .67 .64 .61 .58 .63 .58 .54 .51 .59 .53 .49 .45 .55 .48 .43 .40 .51 .44 .39 .35 .47 .39 .34 .31 .43 .35 .31 .27 .40 .32 .27 .24 .37 .29 .24 .21.74 .74 .68 .65 .63 .57 .57 .51 .52 .45 .47 .40 .43 .35 .39 .31 .35 .27 .32 .24 .29 .21.71 .71 .66 .63 .60 .56 .55 .50 .51 .44 .46 .39 .42 .35 .38 .31 .34 .27 .31 .24 .28 .21.68 .68 .63 .61 .59 .55 .54 .49 .49 .44 .45 .39 .41 .35 .37 .30 .33 .27 .30 .24 .27 .21

RCR

** EFFICIENCY = 63.9% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 150.0

Report No. 2594FR SC = 1.5

White Glass Reflector Catalog No. 406151 / 416WH, 150W A-21, 2780 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 555 90 125 5 550 52 95 133 144 10 540 100 139 15 527 148 105 145 153 20 501 110 149 25 451 205 115 153 151 30 368 120 155 35 278 177 125 156 140 40 204 130 156 45 159 127 135 155 120 50 135 140 154 55 122 111 145 150 94 60 117 150 146 65 115 115 155 140 64 70 116 160 129 75 118 125 165 104 28 80 120 170 56 85 119 132 175 14 2 90 125 180 2

ZONE LUMENS % LAMP %LUMINAIRE 0-30 405 14.59 19.42 0-40 582 20.96 27.90 0-60 821 29.53 39.31 0-90 1192 42.89 57.09 40-90 609 21.93 29.18 60-90 371 13.36 17.78 90-180 896 32.24 42.91 0-180 2088 75.13 100.00

Ceiling 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .82 .74 .70 .66 .63 .67 .61 .56 .52 .61 .54 .48 .44 .57 .49 .43 .38 .53 .44 .38 .33 .49 .40 .34 .29 .45 .36 .30 .26 .42 .33 .27 .23 .39 .30 .25 .21 .37 .28 .23 .19.76 .76 .65 .59 .57 .49 .50 .41 .46 .36 .41 .32 .37 .28 .34 .25 .31 .22 .29 .20 .26 .18.66 .66 .56 .52 .49 .43 .44 .37 .40 .32 .36 .28 .33 .25 .30 .23 .28 .20 .25 .18 .24 .17.56 .56 .47 .44 .42 .37 .38 .32 .34 .28 .31 .25 .29 .23 .26 .20 .24 .18 .22 .17 .21 .15

RCR

** EFFICIENCY = 75.1% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 150.0

Report No. 2640FR SC = 1.0

Amber Glass Reflector Catalog No. 406151 / 416AB, 150W A-21, 2780 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

ANGLE MEAN CP LMS ANGLE MEAN CP LMS 0 638 90 9 5 632 60 95 10 10 10 617 100 10 15 604 170 105 11 12 20 572 110 11 25 516 235 115 12 12 30 423 120 12 35 318 202 125 12 11 40 228 130 12 45 165 132 135 12 9 50 123 140 11 55 94 87 145 11 7 60 74 150 10 65 59 59 155 10 4 70 45 160 9 75 34 36 165 7 2 80 24 170 3 85 15 17 175 0 0 90 9 180 0

ZONE LUMENS % LAMP %LUMINAIRE 0-30 464 16.71 43.65 0-40 666 23.97 62.63 0-60 885 31.84 83.18 0-90 997 35.88 93.74 40-90 331 11.91 31.11 60-90 112 4.04 10.57 90-180 66 2.39 6.26 0-180 1064 38.27 100.00

Ceiling 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method - Effective Floor Reflectance =20% .45 .42 .41 .40 .38 .39 .37 .35 .34 .37 .34 .32 .30 .35 .31 .29 .27 .33 .29 .26 .24 .31 .27 .24 .22 .29 .24 .22 .20 .27 .23 .20 .18 .25 .21 .18 .17 .24 .20 .17 .15.44 .44 .40 .38 .36 .33 .33 .29 .31 .26 .28 .24 .26 .22 .24 .20 .22 .18 .21 .17 .19 .15.41 .41 .38 .36 .35 .32 .32 .29 .29 .26 .27 .23 .25 .21 .23 .19 .22 .18 .20 .16 .19 .15.39 .39 .36 .34 .33 .31 .31 .28 .28 .25 .26 .23 .24 .21 .23 .19 .21 .18 .20 .16 .18 .15

RCR

** EFFICIENCY = 38.3% **

Determined In Accordance With Current IES Published Procedures

Luminaire Imput Watts = 150.0

Report No. 2639FR SC = 1.0

have the same Photometrics.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Group LLC
  • C0605
Show 9 more labels / short text on this page
60° · Room Cavity Ratio · 30° · 60° · Room Cavity Ratio · 30° · 60° · Room Cavity Ratio · 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 406について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 406に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 406 取扱説明書(PDF)

3 ページ·57 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…