Page 1 of 2 2'x4' LAY-IN RECESSED FLUORESCENT STATIC, FLAT STEEL LENS FRAME (XT) REGRESSED ALUMINUM LENS FRAME (XR), 2, 3, 4 LAMPS, T8 OR T12

Exposed T-grid ceiling. Exposed T-grid ceiling.





Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2'x4' LAY-IN RECESSED FLUORESCENT STATIC, FLAT STEEL LENS FRAME (XT) REGRESSED ALUMINUM LENS FRAME (XR), 2, 3, 4 LAMPS, T8 OR T12

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 89 86 83 81 78 76 78 76 74 2 82 76 72 72 68 65 70 67 64 3 76 68 63 65 60 56 63 59 55 4 70 61 55 58 53 49 56 52 48 5 64 55 48 52 47 42 51 46 42 6 59 49 43 47 41 37 46 41 37 7 55 44 38 43 37 33 41 36 32 8 51 40 33 38 33 28 37 32 28 9 47 36 29 34 29 25 34 28 24 10 43 33 26 31 26 22 31 25 22 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 64 68 75 82 61 65 72 79 20 30 57 61 66 73 54 58 63 69 20 40 54 57 62 66 49 53 58 62 20 60 51 54 57 61 46 49 52 57 30 20 65 69 74 80 63 67 72 78 30 30 58 61 65 70 55 59 62 68 30 40 54 57 60 64 50 53 57 60 30 60 50 53 55 59 46 49 51 55 30 80 49 51 52 55 44 46 48 51 40 20 66 70 75 79 65 69 73 78 40 30 59 63 66 70 57 60 64 68 40 40 55 57 60 63 51 54 57 61 40 60 51 53 55 58 47 49 51 54 40 80 49 51 51 54 44 47 48 51 40 100 49 50 50 52 43 45 45 48 60 30 60 63 66 70 58 62 65 69 60 40 55 58 60 63 53 56 58 61 60 60 51 53 55 58 48 50 51 55 60 80 49 51 51 54 45 47 47 50 60 100 49 50 49 51 44 45 45 48 100 40 58 60 62 65 56 59 61 64 100 60 54 55 56 59 51 53 54 57 100 80 51 52 52 55 48 49 49 52 100 100 50 51 50 52 46 47 46 48
G
VA
LAMP QUANTITY:
2, 3 or 4 Lamps VOLTAGE: 120 or 277 OPTIONS: Add appropriate suffix to catalog no,
Fluorescent with Flat Steel Lens Frame XR= Recessed
G = Grid (lay-in
BALLAST TYPE: LE=Magnetic (T12) OC=Magnetic (T8) SS=Electronic (T12) S3=1-3 Lamp Elect. (T12) SO=Electronic Elect. (T8) O3=1-3 Lamp Elect. (T8) O4=1-4 Lamp Elect. (T8) DIM=Dimming (T12) PS=LOL Power Spec T8
LENS/SHIELDING
LAMP/ FIXTURE LENGTH:
WIDTH
Fluorescent with Regressed Aluminum Lens Frame
(standard) see options and consult factory
OPTIONS & ACCESSORIES SPECIAL LENSES: Substitute VB for .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for .125" nominal pattern 12 with 6.9 oz. average weight per square foot. ACCESS PLATES: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP. ELECTRICAL/WIRING OPTIONS: Consult factory. FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.
for safe handling. Lens frames—(XT) flat full-size steel frame, (XR) regressed full-size aluminum frame. FINISH: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W. Listed by Underwriters Laboratories.
SPECIFICATIONS PERFORMANCE: In an installation of 4 lamp 40 W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .78. To reduce glare the VCP shall be not less than 42 either lengthwise or crosswise (at 100 fc level) and the average brightness at 65 shall not exceed 718 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 66%. MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for added strength and rigidity with all edges rolled over