Page 1 of 2 Wall/Ceiling Mounted T-5 Fluorescent ADA Compliant
23-1/4" To Outlet Box Center
48023ALU Powder Coated 28W 120/277V T-5 Miniature Bi-Pin Fluorescent See Below 48023AL54U Metallic Aluminum 54W 120/277V T-5 Miniature Bi-Pin Fluorescent HO
40876 Translucent Etched Soda Lime Glass w/ Pencil Polished Edges 43” L x 6.5” W x 5 mm Thick 40916 Extruded Opal Virgin Acrylic w/ Pencil Polished Edges 43” L x 6.5” W x 5 mm Thick
Options Dimming: (Voltage Specific/54W HO lamps only) Add MX1 suffix code (for 120V) to Cat. No. Add MX2 suffix code (for 277V) to Cat. No. for example: 48023AL4MX1 Emergency: Integral Bodine LP550 emergency battery pack, test switch and light, add E suffix code. DALI: Digital Dimming System ballast 120/277V. For 28W lamps add 28DA suffix code to Cat. No. For 54W lamps add 54DA suffix code to Cat. No. for example: 48023AL54DA
Mounting Mounts directly to switch box or 4” octagonal J-Box. Octagonal box mounting requires use of “J-Box Covers” and “Support Plate” supplied standard.
Labels cULus Listed. Suitable for Damp Locations.
120/277V 28W 54W Total Input Watts: 33W 62W Max. Line Current: 120V = 0.28 120V=.51 277V = 0.12 277V=.21 Power Factor: .98 .98
Job Name:
Cat. No.:
Ballast Factor: 1.00 1.00 THD: 120V =
Lamp(s):
Finish All painted parts utilized the powder coat process. Lightolier Metallic Aluminum Powder Coat Enamel.

Page 2 of 2 Wall/Ceiling Mounted T-5 Fluorescent ADA Compliant
CERTIFIED TEST REPORT NO. 2221FR COMPUTED BY LSI PROGRAM **TEST-LITE** LIGHTOLIER ARCHITECTURAL DECORATIVE LUMINAIRE SOLI
CAT. NO. 48023ALU / 40876, ETCHED GLASS SHIELD 1-28W SYLVANIA T-5 LAMP. LUMEN RATING = 2610 LMS. UNIVERSAL BALLAST #B228PUNVC

CANDLEPOWER ZONE 90 67.5 45 22.5 Beam DEG.
0 2 5 5 4 5 6 6 15 10 13 24 27 25 25 16 30 42 45 43 35 22 41 56 59 59 45 28 52 68 70 74 55 32 60 78 80 85 65 35 67 85 87 94 75 35 72 91 92 100 85 33 75 94 95 103 95 30 77 95 97 104 105 26 77 95 96 102 115 22 74 90 92 97 125 20 68 84 85 90 135 17 61 74 76 79 145 14 50 63 66 66 155 12 41 50 53 50 165 9 25 33 35 33 175 7 11 14 15 15 180 6
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
DISTRIBUTION Zone Lumens % Lamp % Luminaire 0-30 18 0.7 2.87 0-40 43 1.6 6.61 0-60 128 4.9 19.69 0-90 323 12.4 49.44 40-90 279 10.7 42.83 60-90 194 7.4 29.75 90-180 330 12.7 50.56 0-180 653 25.0 100.00
20% FLOOR CAVITY REFLECTANCE