Complete Luminaire consists of Body and Suspension: Order each separately.

Body Cat. No.Finish LampsOptions 4A35642APBU 4A35642ASNUPolished Brass 6-26 Triple Tube Com Satin Nickel or 6-32 Triple Tube C or 6-42 Triple Tube Cpact Fluorescent ompact Fluorescent ompact FluorescentD2 (26W, 120V only), E3 (347V), or EM Add Suffix to Cat. No.
Single Swivel StemMultiple Swivel Stem Suspension Extension Kits Cat. No.Nominal OALCat. No. NominalOAL Cat. No.Nominal OAL Specify Finish as Suffix: PB or SN 4SB115 16 9/16” 4SB118 18” (close-to-ceiling) 4SB121 19 5/16” 4SB124 25 9/16” 4SB128 29 3/8” 4SB135 35” 4SB142 40 5/16” See Specification Sheet(s) 4SB115, 4SB124Specify Finish as Suffix: 4SB224 25 9/16” 4SB228 29 3/8” 4SB235 35” 4SB242 40 5/16” See Specification Sheet 4SBPB or SN Specify Finish as Suffix: PB or SN 4SXT48 48” 4SXT96 96” 224.

Specifications • Suspension Size: For optimum performance testing recommends OAL (over- all length) in proportion to the Body diameter or for close-to-ceiling propor- tion length (see shaded cells). OAL is defined from bottom of diffuser to ceil- ing plane.

Lightolier 4A35 — Architectural Decorative 4A35 diagram (page 1)
図 2 · Architectural Decorative 4A35
  • Stem Wires: Equipped with 120” of leads with keyed connectors for quick connection to Body wiring.

Options & Accessories D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.

Replace Body Cat No. Suffix “U” with Suffix “D2”.

E3 = 347V (Canada)

Replace Body Suffix “U” with Suffix “E3”.

EM = Emergency Battery Pack

Add Suffix “EM” to Body Cat. No.

Multi-Level Switching: Prewired, consult wiring diagram.

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • C0406
FusingConsult Factory
FinishesPB = Polished Brass, SN = Satin Nickel
Page 2 of the Lightolier 4A35 user manual — DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
2ページ · クリックして拡大
2ページ

Architectural Decorative 4A35

Page 2 of 2 Pendalux Cirrus 35” Diameter Body 6-26/32/42 Triple Tube

Features 1. Diffusing Reflector: White translucent acrylic, 3/16” thick. 2. Inner Dirt Shield: White translucent acrylic, 1/8” thick. 3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish. 4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia., fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45˚. Complies with California Code. 5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base. Lamping (by others) Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts. General Electric Osram/Sylvania Philips 26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P 32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P 42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P *Manufacturers’ color temperature designation. Electrical Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage 120/277V, Multi-Wattage 26/32/42W. 6 Lamp 26 Watt 32Watt 42Watt Voltage 120V 277V 120V 277V 120V 277V Total Input Watts 168 168 210 210 279 372 Max. Line Current (amps) 2.22 0.96 2.80 1.20 1.20 1.60 Power Factor >0.98 >0.99 >0.99 Ballast Factor 1.02 1.02 0.96 0.96 0.95 0.95 THD<10% Minimum Starting Temperature: -5°F/-20°C Mounting Mounts directly to 4” outlet box, using crossbar hanger, supplied. Labels cULus listed suitable for damp locations. Application Data 35 Inch Diameter 36’ x 36’ x 11’ Space Luminaire Spacing: 12’ x 12’ Susp. Dist. 35” 6 Lamps 26W 32W 42W TTT TTT TTT Illum. (FC) 33 44 58 Maint. Lum. 8/1 8/1 9/1 Ratio Watts/ 1.15 1.42 1.94 Sq. Ft. Reflectances: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.

CERTIFIED TEST REPORT NO. 4A35642A COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A353642APBU, 35” DIFFUSER 6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS. 3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

Lightolier 4A35 — LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE diagram (page 2)
図 3

C ANDLEPOWER SUMMARY

ANGLE MEAN CP LUMENS 0 655 5 653 62 10 645 15 632 179 20 613 25 591 273 30 566 35 534 334 40 493 45 451 349 50 406 55 361 324 60 315 65 268 267 70 226 75 184 196 80 146 85 110 124 90 90

ANGLE MEAN CP LUMENS 90 90 95 280 422 100 896 105 1385 1435 110 1760 115 2112 2095 120 2458 125 2759 2453 130 2960 135 3096 2391 140 3197 145 3262 2045 150 3303 155 3356 1548 160 3367 165 3147 882 170 2778 175 2734 268 180 2972

ZONAL LUMENS AND PERCENTAGES

DATEDEC. 14, 2000 PREPARED FOR: LIGHTOLIER, FALL RIVER, MA

ZONE LUMENS% LAMP%LUMINAIRE 0-30 514 2.68 3.29 0-40 848 4.42 5.42 0-60 1520 7.92 9.72 0-90 2107 10.98 13.47 40-90 1259 6.56 8.05 60-90 587 3.06 3.75 90-180 13538 70.51 86.53 0-180 15646 81.49 100.00 ** EFFICIENCY = 81.5% **

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80 70 50 30 10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1 .69 .66 .64 .61 .58 .55 .45 .43 .42 .30 .29 .28 .16 .16 .15 .08 2 .60 .56 .52 .53 .49 .46 .39 .36 .34 .26 .24 .23 .14 .13 .13 .07

3 .53 .48 .43 .47 .42 .38 .34 .31 .29 .23 .21 .20 .12 .11 .11 .06 4 .47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .17 .11 .10 .09 .05 5 .41 .35 .31 .37 .31 .27 .27 .23 .21 .18 .16 .14 .10 .09 .08 .04 6 .37 .31 .26 .33 .27 .23 .24 .21 .18 .16 .14 .12 .09 .08 .07 .04 7 .33 .27 .23 .29 .24 .20 .22 .18 .15 .15 .12 .11 .08 .07 .06 .03

35 Inch Diameter 36’ x 36’ x 11’ Space Luminaire Spacing: 12’ x 12’ Susp. Dist. 35” 6 Lamps26W TTT32W TTT42W TTT Illum. (FC) Maint.334458 Lum. Ratio8/18/19/1 Watts/ Sq. Ft.1.151.421.94

ROOM CAVITY RATIO

8 .30 .24 .20 .26 .21 .18 .19 .16 .13 .13 .11 .09 .07 .06 .06 .03 9 .27 .21 .17 .24 .19 .15 .18 .14 .12 .12 .10 .08 .07 .05 .05 .02

10 .24 .19 .15 .22 .17 .14 .16 .13 .10 .11 .09 .07 .06 .05 .04 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • C0406
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 4A35について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 4A35に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 4A35 取扱説明書(PDF)

2 ページ·137 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…