Page 1 of 2 Pendalux Gemini 23” Diameter Body 2-26/32/42 Triple Tube


Replace Body Cat No. Suffix “U” with Suffix “D2”.
E3 = 347V (Canada)
Replace Body Suffix “U” with Suffix “E3”.
EM = Emergency Battery Pack
Add Suffix “EM” to Body Cat. No.
Multi-Level Switching: Prewired, consult wiring diagram. Fusing: Consult Factory Finishes: PB = Polished Brass, SN = Satin Nickel, WH = White

Page 2 of 2 Pendalux Gemini 23” Diameter Body 2-26/32/42 Triple Tube
Features 1. Diffusing Reflector: White translucent acrylic, 3/16” thick. 2. Inner Dirt Shield: White translucent acrylic, 1/8” thick. 3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish. 4. Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia., fas- tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45˚. Complies with California Code. 5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base. 6. Flange Trim: Steel 20 gauge, Plated or Painted finish.
CERTIFIED TEST REPORT NO. 4A23242A COMPUTED BY LSI PROGRAM **TEST-LITE**
CAT. #4A23242, 23” DIFFUSER 2-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS. ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC

ANGLE MEAN CP LUMENS 0 195 5 193 18 10 191 15 189 53 20 184 25 177 82 30 169 35 158 99 40 148 45 137 106 50 126 55 113 101 60 100 65 88 87 70 76 75 64 68 80 53 85 42 47 90 38
ANGLE MEAN CP LUMENS 90 38 95 80 121 100 245 105 437 456 110 604 115 735 725 120 848 125 949 848 130 1035 135 1091 842 140 1133 145 1140 713 150 1125 155 1103 507 160 1051 165 956 267 170 812 175 647 65 180 598
Lamping (by others) Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric Osram/Sylvania Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage N120/277V, Multi-Wattage 26/32/42W.
ZONE LUMENS% LAMP%LUMINAIRE 0-30 153 2.40 2.95 0-40 252 3.95 4.86 0-60 459 7.18 8.83 0-90 661 10.34 12.72 40-90 409 6.39 7.86 60-90 202 3.16 3.88 90-180 4543 70.98 87.28 0-180 5204 81.33 100.00 ** EFFICIENCY = 81.3% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
THD
Mounting Mounts directly to 4” outlet box, using crossbar hanger, supplied.
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
Labels cULus listed (suitable for damp locations).
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .69 .66 .63 .60 .58 .55 .44 .43 .41 .29 .28 .27 .15 .15 .15 .08 2 .60 .55 .51 .53 .49 .45 .38 .36 .34 .25 .24 .23 .13 .13 .12 .07 3 .53 .47 .43 .46 .42 .38 .34 .31 .28 .22 .21 .19 .12 .11 .10 .06

4 .47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .16 .11 .10 .09 .05 5 .41 .35 .30 .36 .31 .27 .27 .23 .20 .18 .16 .14 .09 .08 .08 .04 6 .37 .31 .26 .32 .27 .23 .24 .20 .18 .16 .14 .12 .08 .07 .07 .04 7 .33 .27 .22 .29 .24 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03 8 .30 .24 .20 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03 9 .27 .21 .17 .23 .19 .15 .17 .14 .12 .12 .10 .08 .06 .05 .04 .02 10 .24 .19 .15 .21 .17 .13 .16 .13 .10 .11 .08 .07 .06 .05 .04 .02
Application Data
Reflectances: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75(.88 BF x .85) FC (footcandles) at 30” work plane.