JA
Lightolier logo
公式取扱説明書

Lightolier 4R35

2 ページ·140 KB·インテリア家具・調度品·PDF·EN
Lightolier 4R35
目次 11セクション Architectural Decorative 4R35 · Page 1 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube · Page 2 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube · LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE · … 表示非表示
Page 1 of the Lightolier 4R35 user manual — Architectural Decorative 4R35
1ページ · クリックして拡大
1ページ

Architectural Decorative 4R35

Page 1 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube

Lightolier 4R35 — Architectural Decorative 4R35 diagram (page 1)
図 1 · Architectural Decorative 4R35

Complete Luminaire Consists of Body and Suspension: Order Each Separately.

Body Cat. No.FinishLampsOptions 4R35642APBU 4R35642ASBUPolished Brass Satin Brass6-26 Triple Tube Compact Fluorescent or 6-32 Triple Tube Compact Fluorescent or 6-42 Triple Tube Compact FluorescentD2 (26W, 120V only), E3 (347V), or EM Add Suffix to Cat. No.
Single Swivel StemMultiple to Short Swivel Stem3 Rods to Short SwivelSuspension Ext. Kits Cat. No.Nominal OALCat. No.Nominal OALCat. No.Nominal OALCat. No.Nominal OAL Specify Finish as Suffix: PB or SB 4SB115 16 9/16” 4SB118 18” (close-to-ceiling) 4SB121 19 5/16” 4SB124 25 9/16” 4SB128 29 3/8” 4SB135 35” 4SB142 40 5/16” See Specification Sheet(s) 4SB115, 4SB124Specify Finish as Suffix: PB or SB 4ST228 29 3/8” 4ST235 33” 4ST242 40 5/16” See Specification sheet 4ST228Specify Finish as Suffix: PB or SB 4ST435 35” See Specification Sheet 4ST428Specify Finish as Suffix: PB or SB 4SXT48 48” 4SXT96 96”
  • Specifications
  • Suspension Size: For optimum performance testing recommends OAL (overall length) in proportion to the Body diameter or for close-to-ceiling proportion length (see shaded cells). OAL is defined from bottom of diffuser to ceiling plane.
  • Stem Wires: Equipped with 120” of leads with keyed connectors for quick connection to Body wiring.
Lightolier 4R35 — Architectural Decorative 4R35 diagram (page 1)
図 2 · Architectural Decorative 4R35

Options & Accessories D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.

Replace Body Cat No. Suffix “U” with Suffix “D2”. E3 = 347V (Canada)

Replace Body Suffix “U” with Suffix “E3”. EM = Emergency Battery Pack

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • B0406

Add Suffix “EM” to Body Cat. No. Multi-Level Switching: Prewired, consult wiring diagram. Fusing: Consult Factory. Finishes: PB = Polished Brass, SB = Satin Brass

Page 2 of the Lightolier 4R35 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Architectural Decorative 4R35

Page 2 of 2 Pendalux Traditional 35" Diameter Body 6-26/32/42 Triple Tube

Features 1. Diffusing Reflector: White translucent acrylic, 3/16” thick. 2. Inner Dirt Shield: White translucent acrylic, 1/8” thick. 3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish. 4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code. 5. Rods: Reflector Bowl is suspended from a central point on three 3/16” steel rods. 6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base. 7. Flange Trim: Steel 20 gauge, Plated or Painted finish.

CERTIFIED TEST REPORT NO. 4R35642A COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4R35642SNU, 35” DIFFUSER 6-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS. 3-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

C ANDLEPOWER SUMMARY

Lightolier 4R35 — C ANDLEPOWER SUMMARY diagram (page 2)
図 3

ANGLE MEAN CP LUMENS 0 495 5 497 47 10 490 15 480 136 20 468 25 450 208 30 430 35 404 253 40 373 45 340 263 50 304 55 268 240 60 231 65 190 190 70 154 75 118 126 80 85 85 56 68 90 44

ANGLE MEAN CP LUMENS 90 44 95 235 347 100 757 105 1311 1339 110 1681 115 1932 1913 120 2163 125 2341 2083 130 2442 135 2546 1973 140 2654 145 2727 1707 150 2764 155 2785 1290 160 2818 165 2679 750 170 2401 175 2363 231 180 2540

Lamping (by others) Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric Osram/Sylvania Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P

ZONAL LUMENS AND PERCENTAGES

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P

ZONE LUMENS% LAMP%LUMINAIRE 0-30 424 2.22 3.23 0-40 699 3.64 5.31 0-60 1246 6.48 9.47 0-90 1659 8.64 12.62 40-90 1069 5.01 7.31 60-90 414 2.16 3.15 90-180 12631 65.79 95.98 0-180 14269 74.43 100.00 ** EFFICIENCY = 74.4% **

DATEMAR. 1, 2001 PREPARED FOR: LIGHTOLIER, FALL RIVER, MA

*Manufacturers’ color temperature designation.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

6 Lamp26 Watt32Watt42Watt Voltage Total Input Watts Max. Line Current(amps) Power Factor Ballast Factor120V 168 2.22 >0.98 1.02277V 168 0.96 >0.98 1.02120V 210 1.40 >0.98 0.96277V 210 2.80 >0.98 0.96120V 279 1.20 >0.99 0.95277V 279 1.60 >0.99 0.95

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80 70 50 30 10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1 .58 .55 .53 .51 .49 .46 .37 .36 .35 .24 .24 .23 .13 .12 .12 .08 2 .51 .47 .43 .44 .41 .38 .32 .30 .28 .21 .20 .19 .11 .10 .10 .07

Mounting Mounts directly to 4” outlet box, using crossbar hanger, supplied.

3 .45 .40 .36 .35 .35 .32 .29 .26 .24 .19 .17 .16 .10 .09 .09 .06

Labels cULus Suitable for Damp Locations.

4 .39 .34 .31 .34 .30 .27 .25 .22 .20 .17 .15 .14 .09 .08 .07 .05 5 .34 .30 .26 .31 .26 .23 .22 .20 .17 .15 .13 .12 .08 .07 .06 .04 6 .31 .26 .22 .27 .23 .20 .20 .17 .15 .13 .12 .10 .07 .06 .06 .04

Application Data

7 .28 .23 .19 .24 .20 .17 .18 .15 .13 .12 .10 .09 .06 .05 .05 .03 8 .25 .20 .17 .22 .18 .15 .16 .13 .11 .11 .09 .08 .06 .05 .04 .03 9 .22 .18 .14 .20 .16 .13 .15 .12 .10 .10 .08 .07 .05 .04 .04 .02

35 Inch Diameter 36’ x 36’ x 11’ Space Luminaire Spacing: 12’ x 12’

10 .20 .16 .13 .18 .14 .11 .13 .11 .09 .09 .07 .06 .05 .04 .03 .02

Susp. Dist. 35”

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

2 Lamps 26W 32W 42W TTT TTT TTT

Illum. (FC) Maint. 28 37 49

Lum.Ratio 8/1 8/1 8/1

Watts/Sq. Ft. 1.15 1.42 1.94

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • B0406
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 4R35について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 4R35に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 4R35 取扱説明書(PDF)

2 ページ·140 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…