目次 11セクション Architectural Decorative 4R42 · Page 1 of 2 Pendalux Traditional 42" Diameter Body 8-26/32/42 Triple Tube · Page 2 of 2 Pendalux Traditional 42" Diameter Body 8-26/32/42 Triple Tube · LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE · … 表示非表示
Page 1 of the Lightolier 4R42 user manual — Architectural Decorative 4R42
1ページ · クリックして拡大
1ページ

Architectural Decorative 4R42

Page 1 of 2 Pendalux Traditional 42" Diameter Body 8-26/32/42 Triple Tube

Lightolier 4R42 — Architectural Decorative 4R42 diagram (page 1)
図 1 · Architectural Decorative 4R42

Complete Luminaire Consists of Body and Suspension: Order Each Separately.

Body Cat. No.FinishLampsOptions 4R42842APBU 4R42842ASBUPolished Brass Satin Brass8-26 Triple Tube Compact Fluorescent or 8-32 Triple Tube Compact Fluorescent or 8-42 Triple Tube Compact FluorescentD2 (26W, 120V only), E3 (347V), or EM Add suffix to Cat. No. Single Swivel StemMultiple to Short Swivel Stem3 Rods to Short SwivelSuspension Ext. Kits Cat. No.Nominal OALCat. No.Nominal OALCat. No.Nominal OALCat. No.Nominal OAL Specify Finish as Suffix: PB or SB 4SB115 18 1/4” 4SB118 19 11/16” 4SB121 21” (close-to-ceiling) 4SB124 27 1/4” 4SB128 31 1/16” 4SB135 36 11/16” 4SB142 42” See Specification Sheet(s) 4SB115, 4SB124Specify Finish as Suffix: PB or SB 4SB228 31 1/16” 4SB235 36 11/16” 4SB242 42” See Specification sheet 4ST228Specify Finish as Suffix: PB or SB 4ST442 42” See Specification Sheet 4ST428Specify Finish as Suffix: PB or SB 4SXT48 48” 4SXT96 96”
  • Specifications
  • Suspension Size: For optimum performance testing recommends OAL (overall length) in proportion to the Body diameter or for close-to-ceiling proportion length (see shaded cells).OAL is defined from bottom of diffuser to ceiling plane.
  • Stem Wires: Equipped with 120” of leads with keyed connectors for quick connection to Body wiring.
Lightolier 4R42 — Architectural Decorative 4R42 diagram (page 1)
図 2 · Architectural Decorative 4R42

Options & Accessories D2 = Dimming Electronic Ballast, 26 Watt, 120V, only.

Replace Body Cat No. Suffix “U” with Suffix “D2”. E3 = 347V (Canada)

Replace Body Suffix “U” with Suffix “E3”. EM = Emergency Battery Pack

Add Suffix “EM” to Body Cat. No. Multi-Level Switching: Prewired, consult wiring diagram. Fusing: Consult Factory Finishes: PB = Polished Brass, SB = Satin Brass

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC
  • B0605
Page 2 of the Lightolier 4R42 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Architectural Decorative 4R42

Page 2 of 2 Pendalux Traditional 42" Diameter Body 8-26/32/42 Triple Tube

Features 1. Diffusing Reflector: White translucent acrylic, 3/16” thick. 2. Inner Dirt Shield: White translucent acrylic, 1/8” thick. 3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish. 4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code. 5. Rods: Reflector Bowl is suspended from a central point on three 3/16” steel rods. 6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 lamp base. 7. Flange Trim: Steel 20 gauge, Plated or Painted finish.

CERTIFIED TEST REPORT NO. 4K42842A COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4K42442ASBU, 42” STANDARD DIFFUSER 8-42W T/E SYLVANIA LAMPS, LUMEN RATING = 3200 LMS. 4-ADVANCE BALLAST, #ICF-2S42-M2-LD, 120 VAC

Lightolier 4R42 — LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE diagram (page 2)
図 3

C ANDLEPOWER SUMMARY

ANGLE MEAN CP LUMENS 0 551 5 581 55 10 573 15 560 158 20 543 25 521 241 30 497 35 469 293 40 433 45 393 303 50 349 55 303 272 60 258 65 215 214 70 173 75 122 140 80 93 85 60 99 90 152

ANGLE MEAN CP LUMENS 90 152 95 823 877 100 1416 105 1801 1908 110 2197 115 2598 2545 120 2882 125 3112 2789 130 3329 135 3524 2713 140 3636 145 3788 2385 150 3978 155 4139 1961 160 3626 165 3415 993 170 3357 175 3633 359 180 4032

Lamping (by others) Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric Osram/Sylvania Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F26TBX/*/A/4P CF26DT/E/IN/* PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F32TBX/*/A/4P CF32DT/E/IN/* PL-T32W/*/4P

ZONAL LUMENS AND PERCENTAGES

DATEMAR. 16, 2001 PREPARED FOR: LIGHTOLIER, FALL RIVER, MA

ZONE LUMENS% LAMP%LUMINAIRE 0-30 493 1.93 2.72 0-40 811 3.17 4.46 0-60 1437 5.61 7.90 0-90 1929 7.53 10.60 40-90 1116 4.36 6.14 60-90 491 1.92 2.70 90-180 17843 64.70 98.00 0-180 19772 77.23 100.00 ** EFFICIENCY = 77.2% **

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp F42QBK/*/A/4P CF42DT/E/IN/* PL-T42W/*/4P

*Manufacturers’ color temperature designation.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

26 Watt32Watt42Wa 120V 224 1.84 >.98 1.02277V 224 0.8 >.98 1.02120V 276 2.32 >.98 1.00277V 276 1.04 >.98 1.00120V 364 3.04 >.98 0.98

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80 70 50 30 10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

Mounting Mounts directly to 4” outlet box, using crossbar hanger, supplied.

1 .58 .56 .53 .51 .49 .46 .38 .36 .35 .25 .25 .24 .14 .14 .13 .08 2 .51 .47 .41 .44 .41 .38 .33 .31 .28 .22 .21 .20 .12 .12 .11 .07 3 .49 .40 .36 .39 .35 .32 .29 .27 .24 .20 .18 .17 .11 .10 .10 .06 4 .39 .34 .31 .35 .30 .27 .26 .23 .21 .16 .16 .14 .10 .09 .08 .05 5 .34 .30 .26 .31 .26 .23 .23 .20 .18 .16 .14 .12 .09 .08 .07 .04 6 .31 .26 .22 .27 .23 .20 .20 .17 .15 .14 .12 .11 .08 .07 .06 .04 7 .28 .23 .19 .24 .20 .17 .18 .15 .13 .13 .11 .09 .07 .06 .05 .03

Labels cULus Suitable for Damp Locations.

Application Data

42 Inch Diameter 45' x 45' x 12' Space Luminaire Spacing: 15’ x 15’ Susp. Dist. 42”

8 .25 .20 .17 .22 .18 .15 .17 .14 .11 .11 .09 .08 .06 .05 .05 .03 9 .23 .18 .14 .20 .16 .13 .15 .12 .10 .10 .08 .07 .06 .05 .04 .02 10 .20 .16 .13 .18 .14 .11 .14 .11 .09 .09 .08 .06 .05 .04 .04 .02

8 Lamps 26W 32W 42W TTT TTT TTT

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Illum. (FC) Maint. 25 35 45

Lum. Ratio 11/1 11/1 12/1

Watts/ Sq. Ft. .98 1.21 1.65

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor. Light Loss Factor = .75 (.88 BF x .85) FC (footcandles) at 30” work plane.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 Genlyte Group LLC
  • B0605
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 4R42について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 4R42に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 4R42 取扱説明書(PDF)

2 ページ·102 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…