Page 1 of 2 4 1/2" X 4 1/2" Square Aperture (1) 26/32W Triple Tube
Ceiling Thickness 4 1/2" 5 3/4"
1 1/4" Max.
Features 1. Reflector Trim: Pre-finished aluminum with low iridescence clear finish. 55° visual and reflected cutoff. Overlap flange accommodates different ceiling types. Precision mitered flange corners. 2. Upper Reflector: High efficiency, 97%, Specular Clear. 3. Housing: 22 ga. galvanized formed steel. Centerline notches and holes for consistent alignment of multiple fixtures. Accommodates ceilings up to 1 1/4" thick. 4. Ballast Assembly: Door-mounted for easy service, allows replacement from inside of fixture. 5. Torsiontite Springs: Precision-tooled steel springs secure reflector trim to housing for quick tool-less installation. Positive tension holds flange tight against ceiling. 6. J-Box: 14 ga. galvanized steel. Accessible from inside and outside of the fixture. Outside J-box door is hinged for easy access. 7. Mounting Brackets: 16 ga. steel. Adjustable from inside fixture. Utilize 3/4" or 1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
Electrical UL Listed for through circuit wiring with max of (8) No. 12 AWG, 90°C supply conductors. Note: For complete ballast data and lamp/ballast compatibility refer to “Ballast” specification sheet.
General UL listed for damp locations, I.B.E.W. Union Made. Specular Clear finish (CL) reflector trims meet IES RP-1 practice.

Options & Accessories Chicago Plenum with Fuse (slow blow): Add LCF suffix to Frame-In Kit, consult factory for specifications. Mounting Bars / T-Bar Anchor Clips: See specification sheet “MBA”.

Page 2 of 2 4 1/2" X 4 1/2" Square Aperture (1) 26/32W Triple Tube
32W Triple Tube, Specular Clear Reflector Trim
CANDLEPOWER SUMMARY
Test Report 1763FR Apr.5, 2002 Angle Along 22.5 45 67.5 Across Lumens
Test Report 1710FR Apr. 4, 2002 Angle Along 22.5 45 67.5 Across Lumens

0 546 5 569 576 577 573 572 55 10 580 592 616 644 631 15 552 575 659 651 623 173 20 492 540 623 663 635 25 428 486 588 676 647 263 30 373 428 567 642 584 35 320 370 472 515 508 277 40 254 299 342 407 456 45 179 198 189 272 302 176 50 95 107 98 116 123 55 14 23 32 29 20 36 60 2 2 4 2 2 65 1 0 0 1 1 1 70 75 0 80 85 0 90

0 712 5 721 735 761 772 773 72 10 710 745 803 840 828 15 685 727 808 835 812 220 20 629 678 765 849 855 25 557 611 745 853 844 336 30 485 560 724 834 823 35 408 493 629 718 732 374 40 313 392 500 574 636 45 220 258 297 404 472 252 50 123 136 141 199 224 55 18 31 47 53 38 55 60 2 3 7 5 4 65 1 2 1 2 2 2 70 1 75 0 80 85 0 90
ZONAL LUMENS AND PERCENTAGES Zone Lumens % Lamp % Luminaire 0-30 491 27.29 50.06 0-40 768 42.69 78.31 0-60 980 54.47 99.91 0-90 981 54.52 100.00
ZONAL LUMENS AND PERCENTAGES Zone Lumens % Lamp % Luminaire 0-30 628 26.18 47.89 0-40 1002 41.77 76.42 0-60 1309 54.56 99.82 0-90 1311 54.66 100.00
EFFICIENCY = 54.7% Spacing Criterion: Along = 1.1 Across = 1.5
20% Floor Cavity Reflectance
20% Floor Cavity Reflectance
Based on specular clear (CL) finish. To estimate other finishes, multiply candelas and CU values by 0.95 for CCL, by 0.90 for CCD.