Page 1 of 2 Surface Utility
5000 11-1/8” 6” Matte White N/A (1) A19 75W max. 5001WH118U 11-1/8” 6” Matte White 120/277V Electronic (1) 18W Quad Tube 4-Pin
Features 1. Diffuser: Blown white opal glass. 2. Bracket: Twist-lock fastening system, no tools required. 3. Mounting Pan:.050” min. thickness. Aluminum. 4. Lamps: Compact Fluorescent or Incandescent. (by others) 5. Keyhole Mounting Slots: For direct mounting to 4” octagonal outlet box.
Labels UL Listed, suitable for Damp Locations.
General Electric Osram/Sylvania Phillips
4-pin F18 DBX/SPX*/4P CF18DD/E/* PL-C18W/* *Manufacturers’ color temperature designation.
Job Name:
Cat. No.:
Electronic Ballast: 120V 277V Total Input Watts 19 22 Max. Line Current (amps) .16 .78 Power Factor >.98 >.98 Ballast Factor .95 .98 THD
Lamp(s):
11 1/8" · 6" · Ordering Information

Page 2 of 2 Surface Utility
1 Light - 18W Quad Tube 1250 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
5 10 15 20 25 30 35 40 45 50 55
2 3 4 5 6 7
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
CERTIFIED TEST REPORT NO. 1118FR COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT TRIPLEX CAT. 5001WH118E1 WITH TWIST LOCK OPAL GLASS DIFFUSER
1-18W QUAD TUBE GE LAMP. LUMEN RATING = 1160 LMS. ROBERTSON BALLAST #RED1L10-120R, 120VAC
CANDLEPOWER DATA ANGLE CANDLEPOWER LUMENS 0 102 5 101 10 10 100 15 99 28 20 96 25 94 44 30 90 35 86 55 40 82 45 78 61 50 74 55 69 62 60 64 65 59 59 70 55 75 50 53 80 45 85 41 45
ANGLE CANDLEPOWER LUMENS 90 36 95 33 37 100 30 105 27 30 110 25 115 23 23 120 21 125 20 19 130 19 135 18 15 140 18 145 17 11 150 16 155 15 8 160 14 165 13 4 170 12 175 10 1 180 9 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 80 6.97 14.53 0-40 135 11.65 24.28 0-60 257 22.20 46.27 0-90 413 35.65 74.30 40-90 278 24.00 50.02 60-90 156 13.45 28.03 90-180 143 12.33 25.70 0-180 556 47.98 100.00 ** EFFICIENCY = 48.0% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .45 .43 .41 .43 .41 .39 .39 .37 .36 .35 .34 .32 .31 .30 .29 .27 2 .39 .35 .32 .37 .34 .31 .33 .31 .28 .30 .28 .26 .27 .25 .24 .22 3 .34 .30 .26 .32 .28 .25 .29 .26 .23 .26 .24 .21 .23 .21 .20 .18 4 .30 .26 .22 .29 .25 .21 .26 .22 .20 .23 .20 .18 .21 .19 .17 .15 5 .26 .22 .19 .25 .21 .18 .23 .19 .17 .21 .18 .16 .18 .16 .14 .13 6 .24 .19 .16 .22 .18 .16 .20 .17 .14 .18 .16 .13 .17 .14 .12 .11 7 .21 .17 .14 .20 .16 .13 .18 .15 .12 .16 .14 .11 .15 .12 .11 .09 8 .19 .15 .12 .18 .14 .12 .16 .13 .11 .15 .12 .10 .13 .11 .09 .08 9 .17 .13 .11 .17 .13 .10 .15 .12 .10 .14 .11 .09 .12 .10 .08 .07 10 .16 .12 .09 .15 .11 .09 .14 .11 .08 .12 .10 .08 .11 .09 .07 .06 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES