Page 1 of 2 Surface Utility

Catalog No. Diameter Depth Finish Voltage/Ballast Lamps
5002 12 7/8” 7 3/8” Matte White N/A (2) A19 60W max. 5003WH218U Matte White 120V / 277V Electronic (2) 18W Quad Tube 4-Pin
Features 1. Diffuser: Blown white opal glass. 2. Bracket: Twist-lock fastening system, no tools required. 3. Mounting Pan:.050” min. thickness. Aluminum. 4. Lamps: Compact Fluorescent or Incandescent. (by others) 5. Keyhole Mounting Slots: For direct mounting to 4” octagonal outlet box.
Labels UL Listed, suitable for Damp Locations.
General Electric Osram/Sylvania Phillips
4-pin F18 DBX/SPX*/4P CF18DD/E/* PL-C18W/* *Manufacturers’ color temperature designation.
Job Name:
Cat. No.:
Electronic Ballast: 120V 277V Total Input Watts 42 42 Max. Line Current (amps) .35 .15 Power Factor >.98 >.98 Ballast Factor 1.05 1.05 THD
Lamp(s):

Page 2 of 2 Surface Utility
2 Light - 18W Quad Tube 1250 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room)
20 40 60 80 100 120
3 4 5 6 7 8 9 10 11
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
CERTIFIED TEST REPORT NO. 1046FR COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT TRIPLEX CAT. 5003WH218U WITH TWIST LOCK OPAL GLASS DIFFUSER
2-18W QUAD TUBE GE LAMPS. LUMEN RATING = 1160 LMS. ROBERTSON BALLAST #PSM218CQMVW, 120VAC CANDLEPOWER DATA ANGLE CANDLEPOWER LUMENS
ANGLE CANDLEPOWER LUMENS 90 99 95 90 98 100 80 105 70 74 110 60 115 52 52 120 44 125 38 34 130 32 135 27 22 140 24 145 21 14 150 18 155 17 8 160 16 165 15 5 170 13 175 12 2 180 12 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 203 8.78 14.67 0-40 342 14.74 24.64 0-60 660 28.46 47.56 0-90 1083 46.68 78.01 40-90 741 31.94 53.38 60-90 422 18.22 30.45 90-180 305 13.16 21.99 0-180 1388 59.84 100.00 ** Efficiency 35.8% ** TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
0 255 5 254 25 10 252 15 248 71 20 243 25 236 110 30 229 35 220 139 40 211 45 202 157 50 192 55 181 163 60 170 65 159 158 70 147 75 136 144 80 124 85 112 12
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .57 .54 .51 .54 .51 .48 .49 .47 .45 .44 .43 .41 .40 .39 .37 .35 2 .49 .44 .40 .46 .42 .38 .42 .38 .35 .38 .35 .33 .34 .32 .30 .28 3 .42 .37 .32 .40 .35 .31 .36 .32 .29 .33 .30 .27 .30 .27 .25 .23 4 .37 .32 .27 .35 .30 .26 .32 .28 .25 .29 .26 .23 .27 .24 .21 .19 5 .33 .27 .23 .31 .26 .22 .29 .24 .21 .26 .22 .19 .24 .21 .18 .16 6 .29 .24 .20 .28 .23 .19 .25 .21 .18 .23 .19 .17 .21 .18 .15 .14 7 .26 .21 .17 .25 .20 .16 .23 .18 .15 .21 .17 .14 .19 .16 .13 .12 8 .23 .18 .15 .22 .18 .14 .21 .16 .13 .19 .15 .12 .17 .14 .12 .10 9 .21 .16 .13 .20 .16 .12 .19 .15 .12 .17 .14 .11 .16 .12 .10 .09 10 .19 .14 .11 .19 .14 .11 .17 .13 .10 .16 .12 .10 .14 .11 .09 .08
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES