Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent

Twin Tube Models Quad Tube Models

Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent

3 4 5 6 7 8 9 10 11 12 13 14
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
For 3 light - 26W Quad Tube units multiply FC’s by 0.95
CERTIFIED TEST REPORT NO. 1045FR COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER SURFACE UTILITY FLOURESCENT LUMIDOME CAT. 5241WH239F1 WITH TWIST LOCK ACRYLIC DIFFUSER 2-39W DULUX L SYL.LAMPS. LUMEN RATING = 2900 LMS. ROBERTSON BALLAST #RER2LT8-120H,120VAC CANDLEPOWER DATA ANGLE CANDLEPOWER LUMENS 0 850 5 846 81 10 836 15 819 232 20 795 25 766 354 30 730 35 688 432 40 640 45 589 456 50 532 55 472 423 60 410 65 349 348 70 291 75 237 253 80 189 85 147 162 90 108
ANGLE CANDLEPOWER LUMENS 95 83 92 100 62 105 49 54 110 41 115 39 39 120 38 125 38 35 130 39 135 39 30 140 38 145 38 25 150 38 155 38 18 160 37 165 35 10 170 31 175 32 4 180 33
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 666 11.48 21.92 0-40 1097 18.92 36.11 0-60 1975 34.05 65.01 0-90 2735 47.17 90.04 40-90 1638 28.25 53.93 60-90 760 13.12 25.03 90-180 302 5.22 9.96 0-180 3038 52.39 100.00
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE
LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .53 .50 .48 .51 .49 .47 .48 .46 .44 .45 .43 .42 .42 .41 .40 .38
2 .46 .42 .39 .44 .41 .38 .42 .39 .37 .39 .37 .35 .37 .35 .33 .32
3 .40 .36 .33 .39 .35 .32 .37 .33 .31 .35 .32 .29 .33 .30 .28 .27
4 .36 .31 .28 .35 .31 .27 .33 .29 .26 .31 .28 .26 .29 .27 .25 .23
5 .32 .27 .24 .31 .27 .23 .29 .26 .23 .28 .24 .22 .26 .24 .21 .20
6 .29 .24 .21 .28 .23 .20 .26 .23 .20 .25 .22 .19 .24 .21 .18 .17
7 .26 .21 .18 .25 .21.17 .24 .20 .17 .22 .19 .16 .21 .18 .16 .15
8 .23 .19 .16 .22 .18 .15 .21 .18 .15 .20 .17 .15 .19 .16 .14 .13
9 .21 .17 .14 .21 .16 .14 .19 .16 .13 .19 .15 .13 .18 .15 .12 .11
10 .19 .15 .12 .19 .15 .12 .18 .14 .12 .17 .14 .11 .16 .13 .11 .10 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES For 3 light - 26W Quad Tube units multiply CU’s by 0.95