Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent

Cat. No. Finish Lamps Diameter Depth
(2) 26 W Quad Tube 4-Pin (G24q-3 base)
5533PB226U Polished brass General Electric Osram/Sylvania Philips 16-13/16” 4-3/8” 5533SN226U Satin Nickel F26DBXT4/SPX */4P CF26DD/E/ * PL-C 26W/ * /4P 16-13/16” 4-3/8” 5533WH226U Gloss White * Manufacturers’ color temperature designation. 16-13/16” 4-3/8”
Features 1. Ceiling Pan: Die-formed 16 ga. aluminum. 2. Trim Ring: Formed 16 ga. aluminum. 3. Knob: (3) Turned brass. 4. Diffuser: Formed white translucent acrylic. 5. Mounting Holes: (3) 3/16" Dia., 120° apart on a 3” Dia. Bolt circle. 6. Lamp Socket: See Lamps. 7. Ballast: See Electrical/Ballast 8. Keyhole Mounting Slots: (2) for direct mounting to 4” octagonal outlet box. †9.Emergency Lighting: Add suffix E
Labels UL Listed Suitable for Damp Locations. †UL Listed, (for Indoor Dry Locations only).
(See Specification Sheet SU-EM) 10.Lamps: 26W Compact Fluorescent Quad Tube (by others).
Job Name:
Cat. No.:
Electronic 120/277V Total Input Watts 53 Max. Line Current (Amps) .46 /.21 Power Factor > .98 Ballast Factor 1.0 THD < 10% Min. Starting Temps. -20°C (-4°F)
Lamp(s):

Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent

2 Light - 26W Quad Tube 1800 Lumens Per Lamp
RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor
3 4 5 6 7 8 9 10 11
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.
CERTIFIED TEST REPORT NO. 1104FR COMPUTED BY LSI PROGRAM **TEST-LITE**
CAT.# 5533WH226U WITH ENCLOSED ACRYLIC DIFFUSER 2-26W DULUX D\E SYL.LAMPS. LUMEN RATING = 1800 LMS. ROBERTSON BALLAST #PSM226CQMVW,120VAC CANDLEPOWER DATA ANGLE CANDLEPOWER LUMENS 0 402 5 401 39 10 396 15 388 110 20 377 25 363 168 30 346 35 326 205 40 304 45 281 217 50 255 55 227 205 60 200 65 175 174 70 150 75 127 136 80 106 85 86 94 90 66
ANGLE CANDLEPOWER LUMENS 95 52 58 100 40 105 30 32 110 22 115 18 18 120 15 125 13 12 130 11 135 10 8 140 9 145 9 6 150 8 155 8 4 160 7 165 6 2 170 5 175 5 1 80 5
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 315 8.77 21.29 0-40 520 14.45 35.10 0-60 941 26.14 63.50 0-90 1343 37.33 90.68 40-90 823 22.88 55.58 60-90 402 11.19 27.18 90-180 138 3.84 9.32 0-180 1481 41.16 100.00 ** EFFICIENCY = 41.2% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .41 .39 .37 .40 .38 .36 .37 .36 .34 35 .34 .33 .33 .32 .31 .30
2 .36 .33 .30 .35 .32 .30 .32 .30 .28 .31 .29 .27 .29 .27 .26 .25
3 .31 .28 .25 .30 .27 .25 .29 .26 .24 .27 .25 .23 .25 .23 .22 .21
4 .28 .24 .21 .27 .24 .21 .26 .23 .20 .24 .22 .20 .23 .21 .19 .18
5 .25 .21 .18 .24 .21 .18 .23 .20 .17 .22 .19 .17 .20 .18 .16 .15
6 .22 .18 .16 .22 .18 .15 .20 .17 .15 .19 .17 .15 .18 .16 .14 .13
7 .20 .16 .14 .19 .16 .13 .18 .15 .13 .17 .15 .13 .17 .14 .12 .11
8 .18 .14 .12 .17 .14 .12 .17 .14 .11 .16 .13 .11 .15 .13 .11 .10
9 .16 .13 .10 .16 .13 .10 .15 .12 .10 .14 .12 .10 .14 .11 .10 .09
10 .15 .11 .09 .14 .11 .09 .14 .11 .09 .13 .11 .09 .13 .10 .08 .08
Job Information Type:
180 150 120