READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE INSTRUCTION SHEET NO,
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical Inspector before installation, To prevent electrical shock, turnoff electricity at fuse box before proceeding, IS:6020
Retain these instructions for maintenance reference. R1292 Page 1 of 4
Basic Lytespan track lighting is designed to support and energize LytespotsS which can be attached anywhere along the track. It is a 2-conductor system, polarized and continuously grounded throughout, to be supplied by a single 120V, 60 Hz, 20 amp. branch circuit It maybe used with electrical fittings identified for use with Basic Lytespan Track, It is not intended for use with a power cord or a convenience receptacle adaptor. It is not intended to be pendant mounted by flexible cable. Basic Lytespan is listed by Underwriters Laboratories, Inc.
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
“ THIS TRACK SYSTEM IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL OR FEDERAL CODE SPECIFICATIONS.
. DO NOT INSTALL THIS TRACK IN WET OR DAMP LOCATIONS.
~ DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE FLOOR,
o DO NOT INSTALL ANY FIXTURE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL.
‘ TO PREVENT ELECTRICAL SHOCK, TURN OFF ELECTRICITY AT FUSE BOX BEFORE INSTALLING THE TRACK OR ADDING TO OR CHANGING THE CONFIGURATION OF THE TRACK.
o INSTRUCTIONS FOR GROUNDING PER INSTRUCTION SHEET OF THE FEED-IN KIT USED MUST BE FOLLOWED, FAILURE TO DO SO MAY RESULT IN A HAZARDOUS CONDITION.
~ USE #12 OR 14 GA. AWG SOLID WIRE ONLY (NOT STRANDED WIRE) FOR SUPPLY TO TRACK.
~ OBSERVE POLARITY, (NEUTRAL) WHITE SUPPLY LEAD TO CONTACT MARKED “NEUT” IN LIVE END.
“ DO NOT AllEMPT TO ENERGIZE ANYTHING OTHER THAN TRACK LIGHTING FIXTURES ON THE TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRICAL SHOCK, DO NOT AllEMPT TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES AND THE LIKE TO THE TRACK.
1-1<51-1 TC> L I E 1?”i%iEL:;&:sWRR


2 and 12' track. Do not exceed 4' between clips.
and 12' track. Do not exceed 4' between stems


INSTRUCTION SHEET NO.
R1292 Page 3 of 4
Extend CENTERLINE to length of additional track(s) and fasten additional MOUNTING CLIPS required, (see instruction A-2). Do not exceed 4’ between MOUNTING CLIPS.
Remove DEAD END COVER from INDIVIDUAL TRACK UNIT.
Plug COUPLER of JOINER TRACK UNIT into INDIVIDUAL TRACK UNIT.
Rotate MOUNTING CLIPS into track to secure track to ceiling (see Fig, 3).
Tighten (2) COUPLER SCREWS.
Install additional JOINER TRACK UNITS in the same manner.
Insert DEAD END COVER into end of last JOINER TRACK UNIT in run.
1 r ‘RACK ‘EAD ee
O.K. TRACK BEADS IN LINE
O.K. TRACK BEADS IN LINE
No! TRACK BEADS NOT IN.LINE
No! TRACK BE~~s NOT lN.~,NE
,ND,V,DUAL*
TRACKUNIT
DEAD ENDCOVER
COUPLER
FIG. 4
L COUPLERSCREW
3, · --=%, 7!117 · /-