JA
Lightolier logo
公式取扱説明書

Lightolier 6783WH213N1

2 ページ·88 KB·インテリア家具・調度品·PDF·EN
Lightolier 6783WH213N1
目次 18セクション Decorative Lumiquad ™ 6783WH213N1 · Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent · Ceiling Pan Only · Ordering Information · … 表示非表示
Page 1 of the Lightolier 6783WH213N1 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Decorative Lumiquad ™ 6783WH213N1

Page 1 of 2 Ceiling or Wall Mounted Compact Fluorescent

10 5/16" Sqr.

Ceiling Pan Only

Ordering Information

Catalog Number Finish Ballast

6783WH213N1 Matte White Magnetic NPF 120V 6783BZ213N1 Matte Bronze Magnetic NPF 120V

Features 1. Diffuser: Injection molded white translucent Polycarbonate. 2. Screw: Diffuser removal, tamper proof. 3. Ballast: Magnetic NPF 120V. 4. Ceiling Pan: 16 ga. die formed aluminum 5. Lamps: Compact fluorescent (by others). 6. Mounting: K.O.’s for direct mounting to 3” or 4” octagonal junction boxes.

Electrical Lampholders: Compact Fluorescent: 2-pin, GX23 base Ballast: Magnetic 120V Total Input Watts 28 Max. Line Current (Amps) .72 Power Factor Normal Ballast Factor .8 THD < 10% Min. Starting Temps. 0°C (32°F)

Lamping Compact Fluorescent: (2)13W Twin Tube 2-Pin

General Electric Osram/Sylvania Philips F13BX/SPX* CF 13DS/* PL-S13W/ * *Manufacturers’ color temperature designation. 13W lamp rated to start at 32°F.

Labels UL Listed, Suitable for Wet Locations.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • C0406

2 5/8"

Page 2 of the Lightolier 6783WH213N1 user manual — ROOM CAVITY RATIO
2ページ · クリックして拡大
2ページ

Decorative Lumironde ™ 6783WH213N1

Page 2 of 2 Ceiling or Wall Mounted Compact Fluorescent

INITIAL FOOTCANDLES

2 Light - 13W Twin Tube 900 Lumens Per Lamp

RCR = 1 (60' x60'x8.5' room) RCR = 5 (12' x12'x8.5' room) RCR = 10 (6' x6'x8.5' room) Room surface reflectances 80% Ceiling,50% Walls,20% Floor

5 10 15 20 25 30 35 40 45 50 55

AREA PER FIXTURE IN SQUARE FEET

2 3 4 5 6 7

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET Use quick calculator chart to determine the number and spacing of luminaries for a desired level of illumination.

SPACING RATIO = 1.3

CERTIFIED TEST REPORT NO. 0980FR COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER SURFACE UTILITY FLOURESCENT, LUMIRONDE

CAT. 6731BK213N1 WITH LEXAN DIFFUSER 2-13W TWIN TUBE SYL. LAMPS (DULUX S). LUMEN RATING = 800 LMS. 2-ROBERTSON BALLASTS #S1P, 120VAC

CANDLEPOWER DATA ANGLE CANDLEPOWER LUMENS 0 131 5 131 13 10 130 15 128 37 20 125 25 122 57 30 117 35 111 70 40 105 45 98 76 50 89 55 80 72 60 70 65 59 59 70 48 75 36 39 80 25 85 16 19 90 11

ACROSS 45 ALONG

ANGLE CANDLEPOWER LUMENS 95 8 10 100 7 105 6 7 110 5 115 4 4 120 3 125 2 2 130 1 135 1 1 140 1 145 1 1 150 1 155 1 1 160 1 165 1 1 170 1 175 1 1 180 1

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 104 6.55 22.84 0-40 174 10.91 38.06 0-60 321 20.10 70.10 0-90 436 27.29 95.16 40-90 262 16.38 57.10 60-90 115 7.19 25.06 90-180 22 1.39 4.84 0-180 458 28.68 100.00 ** EFFICIENCY = 28.7% **

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80 70 50 30 10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .29 .28 .27 .29 .28 .26 .27 .26 .25 .26 .25 .24 .25 .24 .23 .23 2 .26 .24 .22 .25 .23 .22 .24 .22 .21 .23 .21 .20 .22 .21 .20 .19 3 .23 .20 .18 .22 .20 .18 .21 .19 .18 .20 .18 .17 .19 .18 .17 .16 4 .20 .18 .16 .20 .17 .15 .19 .17 .15 .18 .16 .15 .17 .16 .14 .14 5 .18 .15 .13 .17 .15 .13 .17 .15 .13 16 .14 .13 .15 .14 .12 .12 6 .16 .13 .12 .16 .13 .11 .15 .13 .11 .14 .12 .11 .14 .12 .11 .10 7 .14 .12 .10 .14 .12 .10 .13 .11 .10 .13 .11 .09 .12 .11 .09 .09 8 .13 .10 .09 .13 .10 .09 .12 .10 .08 .12 .10 .08 .11 .09 .08 .08 9 .12 .09 .08 .11 .09 .08 .11 .09 .07 .11 .09 .07 .10 .08 .07 .07 10 .11 .08 .07 .10 .08 .07 .10 .08 .07 .10 .08 .06 .09 .08 .06 .06

ROOM CAVITY RATIO

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Job Information Type:

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 Genlyte Group LLC
  • C0406

180 150 120

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 6783WH213N1について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 6783WH213N1に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 6783WH213N1 取扱説明書(PDF)

2 ページ·88 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…