目次 22セクション Calculite ® Incandescent Open Downlight 782/7782 · Page 1 of 2 4 1/2” Aperture A19/A21/A23/MB19 Ellipsoidal Reflector · Top View · Molded Trim Ring Flush Trim · … 表示非表示
Page 1 of the Lightolier 7782 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® Incandescent Open Downlight 782/7782

Page 1 of 2 4 1/2” Aperture A19/A21/A23/MB19 Ellipsoidal Reflector

Lightolier 7782 — Calculite ® Incandescent Open Downlight 782/7782 diagram (page 1)
図 1 · Calculite ® Incandescent Open Downlight 782/7782
Lightolier 7782 — Calculite ® Incandescent Open Downlight 782/7782 diagram (page 1)
図 2 · Calculite ® Incandescent Open Downlight 782/7782

Top View

Molded Trim Ring Flush Trim

White or Polished Flange

(Molded trim ring removed)

Ceiling Cutout: 5 1/16” Dia.

Reflector TrimsFrame-In Kit Lamp 782CLW Specular Clear finish with white flange 782CLP Specular Clear finish with polished flange 782CL Specular Clear finish with molded trim ring (flangeless) 782 Add suffix for other finishes (see options)7782 A19 100W MB19 100W A21 150W A23 150W

Features 1. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Can be adjusted without tools from inside or outside of fixture to accommodate different lamp sizes. Contains medium base porcelain socket with nickel plated screw shell wired and No 18 SF1 leads to J-Box. 2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or1 1/2" lathing channels (by others), or Lightolier accessory mounting bars. 3. Retaining Springs: Precision tooled springs secure aperture mounting frame for quick tool-less installation. 4. Reflector: Specular clear Alzak® upper reflector, retained by spring latches for inspection and maintenance, top relampable. 5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Aperture Cone: 16 ga. Specular Alzak® aluminum,or optical black multi- groove. Available with white or polished flange or with removable white molded trim ring (field paintable). 8. Multi-Groove Baffle: One piece seamless aluminum. Sharply detailed concentric rings with "sawtooth" profile, optical black finish. 9. Mounting Collar: Die-formed steel painted in baked black enamel.

Accessories and Options 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Wood Joist Mtg. Bars 7994 (set of 2) Sloped Ceiling Adapters 7920 (see SCA specification sheet) Step Down Transformer 7997 (see separate specification sheet) Chicago Air Plenum LC (add suffix to Frame-in Kit)

Electrical UL Listed for maximum of 8 No. 12, 75°C through branch circuit conductors, or 60°C supply conductors for end of run.

Labels UL Listed for damp locations, I.B.E.W.

Alzak® is a registered trademark of ALCOA.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Other Reflector Finish Options Comfort Clear Diffuse CCD Specular Black BK Specular Gold GD Black Multi-Groove MG (MG is only available with molded trim ring.)

Flange Options White W Polished Flange P Flangeless Leave Blank (molded trim ring)

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902
Page 2 of the Lightolier 7782 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® Incandescent Open Downlight 782/7782

Page 2 of 2 4 1/2” Aperture A19/A21/A23/MB19 Ellipsoidal Reflector

150W A23 2700 Lumens Per Lamp

100W A19 1700 Lumens Per Lamp

INITIAL FOOTCANDLES

INITIAL FOOTCANDLES

RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)

RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)

80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:

80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:

25 50 75 100 125

20 40 60 80 100 120 140 160 180

AREA PER FIXTURE IN SQUARE FEET

AREA PER FIXTURE IN SQUARE FEET

3 4 5 6 7 8 9 10 11 12 13 14

3 4 5 6 7 8 9 10 11 12

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factors: 150W A21; F.C. X 1.3

Use quick calculator chart to determine spacing of luminaires for desired level of illumination.

SPACING RATIO = 1.3 SPACING RATIO = 1.2

Candlepower Summary Candlepower Summary

DEG CP ZONAL FLUX

DEG CP ZONAL FLUX

2 1/2 555 13

2 1/2 825 20

7 1/2 665 48

7 1/2 900 64

12 1/2 745 88

12 1/2 980 116

17 1/2 755 124

17 1/2 880 185

22 1/2 685 144

22 1/2 880 185

27 1/2 595 151

27 1/2 710 180

32 1/2 427 126

32 1/2 530 156

37 1/2 197 66

37 1/2 282 94

42 1/2 59.0 22

42 1/2 117 43

47 1/2 16.2 7

47 1/2 38.4 16

52 1/2 3.2 1

52 1/2 11.4 5

ZONE LUMENS % LAMP

E.T.L, INC. REPORT NO. 385348-A

E.T.L, INC. REPORT NO. 385349-1

ZONE LUMENS % LAMP

0-30 568 33.5

0-30 727 27.0

0-40 760 44.5

0-40 977 36.0

EFFICIENCY: 46.5%

0-60 790 46.5

EFFICIENCY: 38.5%

0-60 1042 38.5

COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE

COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE

80 70 50 30 10 0

80 70 50 30 10 0

50 30 10%WALL REFLECTANCE50 30 10 50 30 1050 30 1050 30 10
50 30 10%WALL REFLECTANCE50 30 100 50 30 1050 30 1050 30 10

1 2 3 4 5 6 7 8 9 10

.52 .51 .50 .51 .50 .49 49 .48 .48 .47 .47 .46 .46 .45 .45 .44 .49 .47 .46 .48 .47 .45 .47 .46 .45 .45 .44 .44 .44 .43 .43 .42 .47 .45 .43 .46 .44 .43 .45 .43 .42 .44 .42 .41 .43 .41 .41 .40 .44 .42 .40 .44 .42 .40 .43. .41 .40 .42 .40 .39 .41 .39 .39 .38 .42 .39 .38 .41 .39 .38 .40 .39 .37 .40 .38 .37 .39 .38 .37 .36 .40 .37 .36 .39 .37 .35 .39 .37 .35 .38 .36 .35 .37 .36 .35 .34 .38 .35 .33 .37 .35 .33 .37 .35 .33 .36 .34 .33 .36 .34 .33 .32 .35 .33 .31 .35 .33 .31 .35 .33 .31 .34 .32 .31 .34 .32 .31 .30 .34 .31 .29 .33 .31 .29 .33 .31 .29 .32 .31 .29 .32 .30 .29 .29 .32 .29 .28 .32 .29 .28 .31 .29 .28 .31 .29 .28 .31 .29 .27 .27

1 2 3 4 5 6 7 8 9 10

.43 .42 .41 .42 .41 .40 .40 .40 .39 .39 .38 .38 .38 .37 .37 .36 .40 .39 .38 .40 .38 .37 .38 .37 .36 .36 .36 .35 .34 .38 .36 .35 .38 .36 .35 .37 .35 .34 .36 .35 .34 .35 .34 .33 .33 .36 .34 .33 .36 .34 .33 .35 .33 .32 .34 .33 .32 .33 .32 .31 .31 .34 .32 .31 .34 .32 .30 .33 .31 .30 .32 .31 .30 .32 .31 .30 .29 .32 .30 .29 .32 .30 .29 .31 .30 .29 .31 .30 .28 .30 .29 .28 .28 .30 .28 .27 .30 .28 .27 .30 .28 .27 .29 .28 .27 .29 .28 .26 .26 .29 .27 .25 .29 .27 .25 .28 .26 .25 .28 .26 .25 .28 .26 .25 .25 .27 .25 .24 .27 .25 .24 .27 .25 .23 .26 .25 .23 .26 .24 .23 .23 .26 .24 .22 .25 .23 .22 .25 .23 .22 .25 .23 .22 .25 .23 .22 .21

ROOM CAVITY RATIO

ROOM CAVITY RATIO

20% FLOOR CAVITY REFLECTANCE

20% FLOOR CAVITY REFLECTANCE

Conversion FactorFor 150W A21 units, multiply C.U.’s by 0.9

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902

11-14-62 · 12-06-62

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 7782について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 7782に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 7782 取扱説明書(PDF)

2 ページ·61 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…