Page 1 of 2 7 3/8” Aperture A19 / A21 / MB19 Fresnel Lenslite

13" 111 1/2"1 1/2"

Ceiling Cutout: 7 3/4” Dia.

Features 1. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Contains medium base porcelain socket, nickel plated screw shell wired with No 18 SF1 leads to J-Box. 2. Mounting Brackets: Adjusts vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or 1/2" lathing channels (by others), 1/2" EMT pipe (by others), or Lightolier accessory mounting bars. 3. Retaining Springs: Torsiontite springs secure bezel reflector housing. 4. Reflector: Specular Alzak® aluminum, 16 ga., reflector housing can be detached from inside of fixture for access to splices after installation. 5. Junction Box: 14 ga. steel, 4" x 3" x 2" box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Trim Frame: Die-cast aluminum suitable for dry or plaster ceilings. Flanges for dry ceilings, reversible flangeless trim for use in plaster ceilings. Matte white baked enamel finish. 8. Bezel: Die-cast aluminum bezel forms deep attractive conical aperture. Matte white baked enamel finish. Includes black polyurethane foam gasket to provide effective light and dust shield. 9. Lens: 6" diameter gray color louver risers. Regressed 1 1/2" from ceiling line by bezel.
Electrical UL Listed for maximum of 8 No. 12, 75°C through branch circuit supply conduc- tors, or 60°C supply conductors for end of run.
Labels UL Listed for wet locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.

Options & Accessories 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Wood Joist Mtg. Bars 7994 (set of 2) Step Down Transformer 7997 (see 7997 specification sheet) Chicago Air Plenum Consult Factory
13"

Page 2 of 2 7 3/8” Aperture A19 / A21 / MB19 Fresnel Lenslite
100 Watt A-19 1750 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:
25 50 75 100 125 150 175 200
10 11 12 13 14 9 8 7 6 5 4 3
Conversion Factors: 150W A21, F.C. X 1.4 Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
100W A19
Candlepower Summary
DEG CP ZONAL FLUX
55 71.0 64
65 25.4 25
75 2.0 2
0-30 461 26.5
0-40 705 40.5
0-60 909 52.0
0-90 936 53.5
E.T.L, Inc. report No. 390909 Date: 06-24-64
80 70 50 30 10 0
1 2 3 4 5 6 7 8 9 10
.59 .57 .56 .58 .56 .55 .55 .54 .53 .53 .52 .52 .51 .51 .50 .49 .54 .52 .50 .53 .51 .49 .51 .49 .48 .50 .48 .47 .48 .47 .46 .45 .50 .47 .44 .49 .46 .44 .47 .45 .43 .46 .44 .42 .45 .43 .42 .41 .45 .42 .40 .45 .42 .39 .44 .41 .39 .43 .40 .38 .41 .40 .38 .37 .42 .38 .35 .41 .38 .35 .40 .37 .35 .39 .37 .35 .38 .36 .34 .33 .38 .35 .32 .38 .34 .32 .37 .34 .32 .36 .34 .31 .036 .33 .31 30 .35 .32 .29 .35 .31 .29 .34 .31 .29 .33 .31 .29 .33 .30 .28 .28 .32 .28 .26 .32 .28 .26 .31 .28 .26 .31 .28 .26 .30 .27 .25 .25 .29 .26 .23 .29 .25 .23 .28 .25 .23 .28 .25 .23 .28 .25 .22 .22 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .25 .22 .20 .19
Job Information Type:
20% FLOOR CAVITY REFLECTANCE