Page 1 of 2 7 3/8” Aperture Horizontal Lamp Fresnel Lenslite

14 1/2" 11 1/2"

Flush Trim Overlap Trim
Ceiling Cutout: 7 7/8" Dia.
Features 1. Socket Cup: Die-formed steel effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Contains medium base porcelain socket with nickel plated screw shell wired with No. 18 SF1 leads to J-Box. 2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or 1 1/2" lathing channels (by others), or Lightolier accessory mounting bars. 3. Retaining Springs: Torsiontite springs secure bezel reflector housing. 4. Reflector: Specular Alzak® aluminum, 16 ga., reflector housing can be detached from inside of fixture for access to splices after installation. 5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Trim Frame: Die-cast aluminum suitable for dry or plaster ceilings. Flanges for dry ceilings, reversible flangeless trim for use in plaster ceilings. Matte white baked enamel finish. 8. Bezel: Die-cast aluminum bezel forms deep attractive conical aperture. Matte white baked enamel finish. Includes black polyurethane foam gasket to provide effective light and dust shield. 9. Lens: 6" diameter gray colouvered risers. Recessed 1 1/2" from ceiling.
Electrical UL listed for maximum of 8 No.12, 75°C through branch circuit supply conduc- tors, or 60°C supply conductors for end of run.
Labels UL Listed for wet locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.

Options & Accessories 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Wood Joist Mtg. Bars 7994 (set of 2) Sloped Ceiling Adapter 7926 (see SCA specification sheet) Step Down Transformer 7997 277v Step Down Transformer (277v primary 1.1 amp/120v secondary, 300w capacity)
13" · 4 1/4"

Calculite ® Incandescent Lensed Downlight
Page 2 of 2 7 3/8” Aperture Horizontal Lamp Fresnel Lenslite
100 Watt A-19 1750 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:
25 50 75 100 125 150 175 200 225
10 11 12 13 14 15 9 8 7 6 5 4 3
Conversion Factors: Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
Candlepower Summary
DEG CP ZONAL FLUX
55 53.4 48
65 26.3 26
75 8.8 9
85 2.6 3
0-30 544 32.0
0-40 791 44.5
ETL, Inc. Report No. 387916-A Date: 08-12-63
0-60 947 55.5
0-90 985 58.0
80 70 50 30 10 0
1 2 3 4 5 6 7 8 9 10
.64 .62 .61 .62 .61 .60 .60 .59 .58 .58 .57 .56 .56 .55 .54 .53 .60 .57 .55 .59 .56 .54 .57 .355 .53 .55 .53 .52 .53 .52 .51 .50 .56 .53 .51 .55 .52 .50 .54 .51 .50 .52 .50 .49 .51 .49 .48 .47 .52 .49 .47 .51 .49 .46 .50 .48 .46 .49 .47 .45 .48 .46 .45 .44 .49 .46 .43 .49 .45 .43 .48 .45 .43 .47 .44 .42 .46 .44 .42 .41 .46 .43 .40 .46 .43 .40 .45 .42 .40 .45 .42 .40 .43 .41 .39 .39 .43 .40 .38 .43 .40 .38 .42 .39 .37 .42 .39 .37 .41 .39 .37 .36 .41 .37 .35 .40 .37 .35 .40 .37 .35 .39 .36 .34 .39 .36 .34 .34 .38 .35 .32 .38 .35 .32 .37 .34 .32 .37 .34 .32 .36 .34 .32 .31 .34 .30 .28 .34 .30 .28 .33 .30 .28 .33 .30 .28 .32 .30 .28 .27
20% Floor cavity reflectance
Conversion Factor: