Page 1 of 2 6” Aperture T4 (T.H.) Ellipsoidal Reflector

Molded Trim Ring Flush Trim (Molded trim ring removed)
Features 1. Socket Cup: Heat dissipating die-cast aluminum with mini-can base porce- lain socket, nickel plated screw shell No.18 SF1 leads to J-Box effectively acts to cool and properly stabilize lamp temperature. Adjustable socket fea- ture allows same fixture to be operated as wide or narrow distribution downlight. 2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or 1 1/2" lathing channels (by others), or Lightolier accessory mounting bars. 3. Retaining Springs: Precision tooled springs secure aperture mounting frame for quick tool-less installation. 4. Reflector: Specular clear Alzak® upper reflector, retained by spring latches for inspection and maintenance, top relampable. 5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Aperture Cone: 16 ga. Specular Alzak® aluminum, or optical black multi- groove. Available with white or polished flange, or with removable white molded trim ring (field paintable). 8. Multigroove Baffle: One piece seamless aluminum. Sharply detailed con- centric rings with "sawtooth" profile, optical black finish. 9. Mounting Collar: Die-formed steel painted in baked black enamel.
Accessories/Options 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Wood Joist Mtg. Bars 7994 (set of 2) Sloped Ceiling Adapters 7925 (see SCA specification sheet) Step Down Transformer 7997 (see 7997 specification sheet) Chicago Air Plenum LC (add suffix to Frame-in Kit, requires access from above ceiling)
Electrical UL Listed for maximum of 8 No. 12, 75˚C through branch circuit conductors, or 60˚C supply conductors for end of run.
Labels UL Listed (Suitable for damp locations), I.B.E.W. Install fixtures with minimum spacing of: 4' between centers of adjacent fix- tures; and 3" between top of fixture and overhead building member; and 2’ between fixture center and building side wall.
Alzak® is a registered trademark of ALCOA.

Other Reflector Finish Options Comfort Clear Diffuse CCD Specular Black BK Specular Gold GD Black Multi-Groove MG
(MG is only available with molded trim ring)
Flange Options White W Polished Flange P Flangeless Leave Blank (molded trim ring)

Page 2 of 2 6” Aperture T4 (T.H.) Ellipsoidal Reflector
SOCKET IN LOW POSITION (PRE-SET) SOCKET IN HIGH POSITION (RE-SET IN FIELD)
500 W T-4 Tungsten Halogen 9500 Lumens Per Lamp
500 W T-4 Tungsten Halogen 9500 Lumens Per Lamp
INITIAL FOOTCANDLES
RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:
80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:
60 120 180 5240 300 360 420 480 540
60 120 180 5240 300 360 420 480 540
21 22 23 24 19 20 18 17 16 14 13 11 15 10 12 9 8 7 6
21 22 23 24 19 20 18 17 16 14 13 11 15 10 12 9 8 7 6
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factor:
Use quick calculator chart to determine spacing of luminaires for desired level of illumination. Conversion Factor:
400W T-4: F.C. X 0.8
Spacing Ratio = 1.0 Spacing Ratio = 0.3
DEG CP ZONAL FLUX
ITL, Inc. report No. 12327 Date: 12-9-69
0-30 6327 66.4 82.9
0-40 7269 76.3 95.2
0-60 7455 78.3 97.7
0-90 7592 79.7 100
80 70 50 30 10 0
1 2 3 4 5 6 7 8 9 10
.90 .88 .86 .88 .86 .85 .85 .84 .82 .82 .81 .80 .79 .78 .78 .76 .84 .81 .79 .83 .80 .78 .80 .78 .76 .78 .76 .75 .76 .74 .73 .72 .80 .76 .74 .79 .76 .73 .77 .74 .72 .75 .73 .71 .73 .71 .70 .69 .76 .72 .69 .75 .71 .69 .73 .70 .68 .72 .69 .67 .70 .68 .66 .65 .72 .68 .65 .71 .67 .65 .70 .66 .64 .68 .66 .63 .67 .65 .63 .62 .69 .65 .62 .68 .64 .62 .67 .64 .61 .66 63 .61 .65 .62 .60 .59 .66 .62 .59 .65 .61 .59 .64 .61 .58 .63 .60 .58 .63 .60 .58 .57 .63 .59 .56 .62 .58 .56 .61 .58 .55 .61 .58 .63 .60 .57 .55 .54 .59 .55 .53 .59 .55 .53 .58 .55 .53 .58 .55 .52 .57 .54 .52 .51 .57 .53 .50 .56 .52 .50 .56 .52 .50 .55 .52 .50 .54 .52 .49 .49
20% FLOOR CAVITY REFLECTANCE
Conversion Factor: For 400W T4 units, multiply C.U.’s by 1.0 ITL, Inc. Report No. 12327C; Date: 12-9-69