目次 12セクション Calculite ® Compact Fluorescent Open Wall Washer 8011WW · Page 1 of 2 4” Aperture Triple Tube Vertical Lamp · Reflector Trim Frame-In Kit Lamp · Job Information Type: · … 表示非表示
Page 1 of the Lightolier 8011WW user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® Compact Fluorescent Open Wall Washer 8011WW

Page 1 of 2 4” Aperture Triple Tube Vertical Lamp

2 5 4 1 6

8 1/16" (210 mm)

18W8" (204 mm)

3 3/8" (86 mm)

10 1/2" (267 mm)

4 1/4 (108 mm) Dia.

1 1/8" (29 mm) max. Ceiling Thickness 3

1" (25 mm) min. - 2 1/8" (54 mm) max.

Flush 5" (127 mm)

Overlap 5 3/4" (147 mm)

Ceiling Cutout: 5 1/16” (129 mm) Dia.

Reflector Trim Frame-In Kit Lamp

8011WW CCLW Comfort Clear™, White Flange 4118VU Electronic 120V - 277V 18W Triple Tube 8011WW CCLP Comfort Clear™, Polished Flange 4-Pin (Amalgam) 8011WW CCL Comfort Clear™, Molded Trim Ring 8011WW Add suffix. See options for other finishes.

Features 1. Downlight/Wall Washer Reflector: 16 ga. Alzak® aluminum. 50° lamp cutoff and lamp image. Provides vertical surface wall wash and downlighting. Comfort Clear™low iridescence finish. Self-flanged or flangeless with molded white trim ring (field paintable). 2. Socket Cup: Die-cast aluminum cup effectively dissipates heat and positions lamp holder. Snaps onto reflector neck to assure consistently correct optical alignment without tools. 3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. Accepts other 4" triple tube reflectors. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or 1 1/2” lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools. Provides vertical surface wall wash and downlighting.

Options and Accessories (continued) Emergency Add suffix EM* Chicago Plenum Add suffix LC Emergency Ltg. Kit FA EM3E* FA EM4E* Fuse (Slow Blow) Add suffix F *See Spec. Sheets: FAEM

Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.

IC Frame available; see C4CFL18 Specification Sheet.

Labels UL Listed for damp locations, I.B.E.W.

Alzak® is a registered trademark of ALCOA. US Patent Pending.

Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.

Job Information Type:

UL Listed for through branch circuit wiring with max of (8) No. 12 AWG, 90°C supply conductors.

Job Name:

Cat. No.:

Options and Accessories Comfort Clear™Finishes1 Other Finishes Diffuse CCD White WH Champagne Bronze CCZ Pewter CPW

Lamp(s):

1Specify desired flange W White, P Polished Blank - Molded Ring

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902

11 1/2" (292mm) · Top View · 3" (76 mm)

Page 2 of the Lightolier 8011WW user manual — ROOM CAVITY RATIO
2ページ · クリックして拡大
2ページ

Calculite ® Compact Fluorescent Open Wall Washer 8011WW

Page 2 of 2 4” Aperture Triple Tube Vertical Lamp

Lighting Data

Footcandles On Wall: Multiple 18W Triple Tube Units

Lightolier 8011WW — Lighting Data diagram (page 2)
図 1 · Lighting Data

Example: With multiple clear reflector units located 2' from wall and spaced 2' on center (matching downlights 5' on center), the illumination on the wall 3' down from ceiling will be 14 f.c. beneath units and 18 f.c. between units.

Footcandle values are averaged and rounded off and are based on a minimum of five units.

2’ From Wall-2’ On Center

2’ From Wall-3’ On Center

Lightolier 8011WW — 2’ From Wall-2’ On Center diagram (page 2)
図 2 · 2’ From Wall-2’ On Center
2’ From Wall-4’ On Center 4 1 11 3 11 et2 13 5 13 n Fe3 11 7 11 ng i4 8 8 8 Ceili5 6 6 6 om6 5 5 5 e Fr7 4 4 4 tanc8 3 3 3 Dis9 3 3 3
Lightolier 8011WW — 2’ From Wall-2’ On Center diagram (page 2)
図 3 · 2’ From Wall-2’ On Center

1 14 12 14 2 17 16 17 3 18 18 18 4 16 16 16 5 12 12 12 6 10 10 10 7 8 6 6 6 9 4 4 4

1 11 6 11 2 14 9 14 3 12 12 12 4 10 11 10 5 8 8 8 6 7 5 5 5 8 4 4 4 9 3 3 3

Candlepower Distribution Downlight Spacing Ratio 1.3 Coefficients of Utilization

Downlight Side Wall Washer Side

Lightolier 8011WW — Candlepower Distribution Downlight Spacing Ratio 1.3 Coefficients of Utilization diagram (page 2)
図 4 · Candlepower Distribution Downlight Spacing Ratio 1.3…
80705030100 50 30 10WALL REFLECTANCE 50 30 10 50 30 10 50 30 1050 30 100 1 2 3 4 5 6 7 8 9 10.46 .45 .44 .43 .41 .39 .40 .37 .36 .37 .35 .33 .34 .32 .30 .32 .30 .28 .30 .27 .26 .28 .25 .23 .26 .23 .22 .24 .22 .20.45 .44 .43 .42 .40 .39 .39 .37 .36 .36 .34 .33 .34 .32 .30 .32 .29 .28 .30 .27 .25 .27 .25 .23 .26 .23 .22 .24 .22 .20.43 .43 .42 .41 .39 .38 .38 .36 .35 .36 .34 .32 .33 .31 .30 .31 .29 .27 .29 .27 .25 .27 .25 .23 .25 .23 .21 .24 .21 .20.42 .41 .41 .39 .38 .37 .37 .36 .34 .35 .33 .32 .32 .31 .29 .31 .29 .27 .28 .26 .25 .27 .25 .23 .25 .23 .21 .23 .21 .20.40 .40 .39 .38 .37 .37 .36 .35 .34 .34 .33 .31 .32 .30 .29 .30 .28 .27 .28 .26 .25 .26 .24 .23 .24 .23 .21 .23 .21 .20.39 .36 .33 .31 .28 .26 .24 .22 .21 .19

ROOM CAVITY RATIO

20% FLOOR CAVITY REFLECTANCE

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 8011WWについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 8011WWに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 8011WW 取扱説明書(PDF)

2 ページ·80 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…