Page 1 of 2 6" Aperture (2) Quad Tube Horizontal Lamp

1" (25 mm) min.- 2-1/8" (54 mm) max. 1-1/8" (29 mm) max. Ceiling Thickness
Ceiling Cutout: 6 9/16" (167 mm) Dia.

Features 1. Reflector: 16 ga. Alzak® aluminum, 55° visual cutoff to lamp and lamp image, wide distribution. Iridescence Free finish. Self-flanged or flangeless with molded white trim ring (field paintable). 2. Socket Cup: Die-cast zinc cup effectively dissipates heat and positions lamp holder. Snaps onto reflector neck to assure consistently correct optical alignment without tools. 3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 1 1/2" lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools.
Options and Accessories (continued) Emergency Add suffix EM* Chicago Plenum Add suffix LC Existing/Thk. Ceiling FA EC6* Emergency Ltg. Kit FA EM3E* (4 pin) FA EM4E* (4 pin) FA EM1T* (2 pin) Fuse (Slow Blow) Add Suffix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels UL listed for damp locations, I.B.E.W.
Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
Alzak® is a registered trademark of ALCOA. US Patent Pending

UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.
Options and Accessories Comfort Clear™ Finishes1 Other Finishes Clear CCL White WH Diffuse CCD Mulitgroove MG Champagne Bronze CCZ
1Specify desired flange W White, P Polished Blank - Molded Ring
13-5/8" (346 mm) · 10" (254 mm) · 11-1/8" (283 mm)

Page 2 of 2 6" Aperture (2) Quad Tube Horizontal Lamp
13W
Quick Calculator
ROOM SURFACE REFLECTANCES: 80% Ceiling; 50% Wall, 20% Floor 860 Lumens Per Lamp RCR= 1 (Rm. Width = 10xMtg. Ht. above work plane) RCR= 5 (Rm. Width = 2xMtg. Ht. above work plane) RCR=10 (Rm. Width = Mtg. Ht. above work plane)
10 20 30 40 50 60 70 80 90
3 4 5 6 7 8 9 10
This quick calculator chart determines the number and spacing of 2 lt.-13W Quad Tube units with clear or clear incandescent free reflector, for any level of illumination.
Certified Test Report Number: LSI 9474 COMPUTED BY: LSI PROGRAM “TEST-LITE” PREPARED FOR: LIGHTOLIER INC. APERTURE: 7 3/8” REFLECTOR: SPECULAR CLEAR, OPEN BOTTOM LAMPS: TWO OSRAM DOUBLE DULUX 13W/41 QUAD TUBES RATED AT 860 LUMINES.
CANDELPOWER SUMMARY Angle Along 22.5 45 67.5 Across Lumens 0 418 5 406 412 422 439 442 41 10 400 410 441 471 490 15 388 414 455 497 526 129 20 378 427 470 493 542 25 411 442 514 499 532 222 30 409 461 509 512 535 35 397 437 500 515 524 290 40 347 369 415 430 446 45 267 279 291 307 324 214 50 114 113 111 121 134 55 18 11 13 13 17 33 60 4 3 4 3 4 65 3 1 2 2 3 2 70 1 0 1 0 2 75 1 0 0 0 1 0 80 85 0 90
ZONAL LUMENS AND PERCENTAGES
Zone Lumens % Lamp % Luminaire 0–30 391 22.74 42.01 0–40 681 39.60 73.16 0–60 928 53.98 99.73 0–90 930 54.13 100.00 40–90 249 14.53 26.84 60–90 2 .15 .27 90–180 0 .00 .00 0–180 930 54.13 100.00
DATE: MAY 22, 1990
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE = 7.9 METERS (26.0 Ft.)
For Units with Clear or Clear Irridescence Free reflector, multiply C.U.’s by 1.0.