Page 1 of 2 7" Aperture (2) Twin Tube Parabolic Louver

1" (25mm) min. 2 1/8"(54mm) max. 7 3/8"(187mm) Dia.
Ceiling Cutout: 8" (203 mm) Dia.

Features 1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image. 2. Parabolic Louver: 18ga. prefinished reflector aluminum, 50° visual cutoff to lamp and lamp image. Snap-in, snap-out system allows easy louver removal for lamping. Louver / reflector / socket support can be rotated up to 40° for horizontal alignment. 3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. 4. Socket Support: Die-formed steel with venting to dissipate heat. Assures lamps maintain proper optical alignment to reflector. Can be rotated with reflector / louver for horizontal alignment. Pre-wired with No. 18 ga. AWM leads. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or 1 1/2” lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools.
Options and Accessories (continued) Emergency Add suffix EM* Chicago Plenum Add suffix LC Emergency Ltg. Kit FAEMIT Fuse (Slow Blow) Add Suffix F *See Spec. Sheets: FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels UL listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA. US Patent Pending
Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.

UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.
Clear CCL Diffuse CCD
1Specify Desired Flange P-polished, W-white Blank - Molded Trim Ring
5 1/8" (133mm) · (200mm)

Page 2 of 2 7" Aperture (2) Twin Tube Parabolic Louver

CERTIFIED TEST REPORT NO. 1162FR COMPUTED BY LSI PROGRAM **TEST-LITE** CALCULITE LOW PROFILE RECESSED 7” HORIZONTAL FLUORESCENT DOWNLIGHT SPECULAR CLEAR FINISH REFLECTOR AND CROSS BLADE 2-13W TWIN TUBE SYLVANIA COMPACT FLUORESCENT LAMPS. LUMEN RATING = 800 LMS. MAGNETEK BALLAST,CAT.# 4114 PBES,120V AC

CANDLEPOWER DATA IN 2.5 DEGREE STEPS ANGLE ALONG 22.5 45 67.5 ACROSS OUTPUT LUMENS
0 496 5 506 506 515 522 522 49 10 519 530 556 564 564 15 510 535 576 582 574 157 20 506 528 570 578 597 25 488 504 548 572 589 245 30 426 435 480 524 507 35 305 323 346 387 374 214 40 159 183 198 191 196 45 67 83 91 76 72 71 50 14 19 26 18 14 55 3 2 4 2 2 6 60 1 65 0 70 75 0 80 85 0 90 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 451 28.23 60.81 0-40 665 41.59 89.61 0-60 742 46.38 99.93 0-90 742 46.42 100.00 40-90 77 4.82 10.39 60-90 0 .03 .07 90-180 0 .00 .00 0-180 742 46.42 100.00 ** EFFICIENCY = 46.4% **
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .52 .51 .50 .51 .50 .49 .49 .48 .48 .47 .47 .46 .46 45 .45 .44 2 .49 .47 .46 .48 .46 .45 .46 .45 .44 .45 .44 .43 .44 .43 .42 .42 3 .46 .44 .42 .45 .43 .42 .44 .42 .41 .43 .42 .40 .42 .41 .40 .39 4 .43 .41 .39 .43 .40 .39 .42 .40 .38 .41 .39 .38 .40 .38 .37 .37 5 .40 .38 .36 .40 .37 .36 .39 .37 .35 .38 .37 .35 .38 .36 .35 .34 6 .38 .35 .34 .38 .35 .33 .37 .35 .33 .36 .34 .33 .36 .34 .33 .32 7 .35 .33 .31 .35 .33 .31 .35 .32 .31 .34 .32 .31 .34 .32 .30 .30 8 .33 .31 .29 .33 .30 .29 .32 .30 .29 .32 .30 .28 .32 .30 .28 .28 9 .31 .28 .26 .31 .28 .26 .30 .28 .26 .30 .28 .26 .29 .28 .26 .25 10 .29 .26 .24 .29 .26 .24 .28 .26 .24 .28 .26 .24 .28 .26 .24 .24
Job Information Type:
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。