1" (25 mm) min. 2-1/8" (54 mm) max. 1-1/8" (29 mm) max Ceiling Thickness.
Features 1. Downlight Wall Washer Reflector: 16 ga. Specular Alzak® aluminum, 55° lamp cutoff to lamp and lamp image. Provides vertical surface wall wash and downlighting. Iridescence Free finish. Self-flanged or flangeless with molded white trim ring (field paintable). 2. Socket Cup: Snaps onto reflector neck to assure consistently correct optical alignment without tools. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 1 1/2" lathing channel, 1/2" EMT, or optional mounting bars. 6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools.
Options and Accessories (continued) Emergency Add suffix EM* Chicago Plenum Add suffix LC Existing/Thk. Ceiling FA EC7* Emergency Ltg. Kit FA EM3E* (4 pin) FA EM4E* (4 pin) FA EM2T* (2 pin) Fuse (Slow Blow) Add Suffix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCAπ
Labels UL listed for damp locations, I.B.E.W.
Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90° C supply conductors.

Options and Accessories Comfort Clear™ Finishes1 Other Finishes Clear CCL White WH Diffuse CCD Champagne Bronze CCZ
1Specify desired flange W White, P Polished Blank - Molded Ring

EXAMPLE: With multiple clear reflector units located 3’ from wall and 4’ on center, (matching downlights 4’ on center), the illumination on the wall 3’ down from the ceiling is 21 f.c. beneath and between fixtures.
21 f.c. 21 f.c.
Footcandles On Wall From Multiple Units 26W Quad Tube - Clear And Clear If Reflector
2’ 3’ Units 2 Feet From Wall
1 2 3 4 5 6 7 8 9
57 55 57 60 63 60 50 54 50 41 43 41 31 32 31 23 13 23 17 17 17 13 13 13 10 10 10
45 30 45 41 39 41 31 36 31 27 31 27 22 24 22 17 18 17 13 14 13 10 10 10 8 8 8
43 16 43 36 24 36 23 25 23 20 23 20 17 19 17 13 15 13 10 11 10 8 9 8 6 7 6
Distance From Ceiling, Ft.
3’ 4’ Units 3 Feet From Wall
1 2 3 4 5 6 7 8 9
12 8 12 25 21 25 21 21 21 17 19 17 16 18 16 14 16 14 12 13 12 11 11 11 9 9 9
11 5 11 24 15 24 18 15 18 13 15 13 12 14 12 11 13 11 10 11 10 9 10 9 8 8 8
10 3 10 23 11 23 16 11 16 11 11 11 10 12 10 9 11 9 9 10 9 8 8 8 6 7 6
16 14 16 30 30 30 27 29 27 24 26 24 22 23 22 19 20 19 16 16 16 13 13 13 11 11 11
Distance From Ceiling, Ft.
Footcandles values are averaged and rounded off and are based on a minimum of five units.
Candlepower Distribution Coefficients Of Utilizationn


% Effective Ceiling Cavity Reflectance 80 50 10 %Wall Reflectance 50 30 10 50 30 10 50 30 10 1 .54 .52 .51 .51 .50 .49 .47 .46 .46 2 .49 .47 .44 .47 .45 .43 .44 .42 .41 3 .45 .42 .39 .43 .40 .38 .40 .38 .37 4 .41 .37 .35 .39 .36 .34 .37 .35 .33 5 .37 .34 .31 .36 .33 .31 .34 .32 .30 6 .34 .30 .28 .33 .30 .27 .31 .29 .27 7 .31 .27 .25 .30 .26 .24 .28 .26 .24 8 .28 .24 .22 .27 .24 .22 .26 .23 .21 9 .26 .22 .19 .25 .21 .19 .24 .21 .19 10 .23 .19 .17 .22 .19 .17 .22 .19 .17


EXAMPLE: With multiple clear reflector units located 2’ from wall and 3’ on center, (matching downlights 3’ on center), the illumination on the wall 3’ down from the ceiling is 20 f.c. beneath and 23 f.c. between fix- tures.
Footcandles On Wall From Multiple Units 18W Quad Tube - Clear and Clear IF Reflector
3’ 4’ Units 3 Feet From Wall

Distance From Ceiling, Ft.
Footcandles values are averaged and rounded off and are based on a minimum of five units.
Candlepower Distribution Coefficients of Utilization
% Effective Ceiling Cavity Reflectance 80 50 10 %Wall Reflectance 50 30 10 50 30 10 50 30 10 1 .57 .55 .54 .54 .52 .51 .50 .49 .48 2 .52 .49 .47 .49 .47 .46 .46 .45 .44 3 .47 .44 .42 .45 .43 .41 .43 .41 .39 4 .43 .40 .37 .42 .39 .37 .39 .37 .36 5 .40 .36 .33 .38 .35 .33 .36 .34 .32 6 .36 .33 .30 .35 .32 .29 .33 .31 .29 7 .33 .29 .27 .32 .29 .26 .31 .28 .26 8 .30 .26 .24 .29 .26 .24 .28 .25 .23 9 .28 .24 .21 .27 .23 .21 .26 .23 .21 10 .25 .21 .19 .24 .21 .19 .23 .21 .18


Lighting Data · Room Cavity Ratio