Page 1 of 2 8 3/4” Aperture (2) 26/32/42W Triple Tube Vandal / Wet Location

Ceiling Cutout: 10 1/4” (257 mm) Dia.

Features 1. Rotolock Ring: Die-cast aluminum; matte white finish. Sealed o-ring con- struction provides the wet location seal. Single allen-head set screw locks the ring in place to prevent vandalism. 2. Lens: High impact acrylic, semi-transparent diffuser. Available in Flush lens (8098VWH) and Drop Lens (8098DVWH). 3. Reflector: 16 Ga. Die-formed aluminum, clear anodized finish. 4. Socket Bracket: Die-formed steel. Attaches to reflector without tools, assures proper optical alignment of lamps. 5. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. 6. Retaining Springs: Rust resistant springs simplify reflector/housing removal for inspection and maintenance. 7. Mounting Brackets: 16 ga. steel. Adjustable from inside of fixture. Use 3/4" or 1 1/2" lathing channel, 1/2" EMT, or optional 27" mounting bars (see separate specification sheet “MBA”). 8. Junction Box: 14 ga. steel, 4" (102 mm) x 3 1/2" (89 mm) x 2" (51 mm) box, allows inspection from below. UL certified for through branch circuit wiring with maximum of 8 no. 12, 90° C conductors. 9. Electronic Ballast: High Power Factor, thermally protected class “P”, no visible flicker on starting, internally fused and protection circuit for lamp end- of-life. Sound rated “A”. Designed for removal without tools from inside of fixture. Separate Switching Frame-in Kit is equipped with two separate ballasts. 10.Emergency Battery Pack Frame-In Kit: Electronic, fully encased and prewired nickel cadmium long life battery replaceable from below. Test switch and charge light included in easy to install recessed switch box with 4 1/2" dia. matte white cover plate; switch box and charge light can be installed up to 50 feet from fixture. One lamp is illuminated at initial lumens of 450 (26W), 575 (32W) and 750 (42W) light output for 90 minutes when power fails.
Options and Accessories Mounting Bars: See specification sheet “MBA” T-Bar Anchor Clips: See specification sheet “MBA” Fuse (Slow Blow): Add suffix “F” Emergency Ltg. Kit: FAEM3E, FAEM4E (see “FAEM” specification sheet)
Electrical For ballast electrical data, latest lamp / ballast compatibility, refer to “Ballast” specification sheet.

5 1/4" (133mm)

Page 2 of 2 8 3/4” Aperture (2) 26/32/42W Triple Tube Vandal / Wet Location
Quick Calculator
ROOM SURFACE REFLECTANCES:
80% Ceiling; 50% Wall; 20% Floor
2400 Lumens Per Lamp
RCR = 1 RCR = 5 RCR = 10
(Rm. width = 10 x Mtg. Ht. above work plane) (Rm. width = 2 x Mtg. Ht. above work plane) (Rm. width = Mtg. Ht. above work plane)
25 50 75 100 125 150 175 200
4 5 6 7 8 9 10 11 12 13 14 15
This quick calculator chart determines the number and spacing of 2 lt. - 32W TTT units with CLEAR reflector, for any level of illumination. Lighting Conversion Factors = 26W, F.C. X 0.8; 42W, F.C. X 1.3)
CANDLEPOWER SUMMARY
Angle Along 22.5 45 67.5 Across Lumens 0 736 5 734 740 743 739 732 71 10 731 433 727 724 731 15 716 413 716 715 727 202 20 687 694 687 691 690 25 661 666 665 668 656 305 30 625 629 637 629 622 35 589 594 590 597 590 367 40 544 544 539 537 552 45 496 489 489 488 492 378 50 443 434 440 437 439 55 381 384 374 371 371 338 60 321 319 312 320 310 65 254 264 249 248 253 250 70 186 198 191 192 186 75 126 129 126 117 125 133 80 68 56 54 59 63 85 9 17 19 12 20 21 90
ZONAL LUMENS AND PERCENTAGES Zone Lumens % Lamp % Luminaire 0-30 577 12.04 27.97 0-40 945 19.70 45.76 0-60 1662 34.63 80.44 0-90 2066 43.04 100.00 40-90 1120 23.35 54.24 60-90 404 8.42 19.56 90-180 0 0.00 0.00 0-180 2066 43.04 100.00
25° 15° 5°
Certified Test Report Number: LSC8203 Computed By: Lighting Sciences Canada ltd. Prepared For Lightolier CFI Aperture: 8 3/4" Dia. Reflector: Specular Clear Alzak Lamps: 2 x 32W TTT Rated at 2400 Lumens
Ceiling Cavity Reflectance 80 70 50 30 10 0 Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .45 .44 .42 .45 .43 .42 .43 .41 .40 .41 .40 .39 .39 .39 .38 .37 2 .40 .38 .35 .39 .37 .35 .38 .36 .34 .37 .35 .33 .35 .34 .33 .32 3 .36 .32 .30 .35 .32 .30 .34 .31 .29 .33 .30 .29 .32 .30 .28 .27 4 .32 .28 .26 .31 .28 .26 .30 .27 .25 .29 .27 .25 .28 .26 .25 .24 5 .29 .25 .22 .28 .25 .22 .27 .24 .22 .26 .24 .22 .26 .23 .21 .21 6 .26 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .23 .21 .19 .18 7 .23 .19 .17 .23 .19 .17 .22 .19 .17 .21 .18 .16 .21 .18 .16 .15 8 .21 .17 .15 .20 .17 .15 .20 .17 .15 .19 .17 .14 .19 .16 .14 .14 9 .19 .15 .13 .19 .15 .13 .18 .15 .13 .18 .15 .13 .17 .15 .13 .12 10 .17 .14 .12 .17 .14 .11 .17 .14 .11 .16 .13 .11 .16 .13 .11 .11
For 26W and 42W lamps, multiply C.U.'s X 1.0.