Page 1 of 2 Lyteflood ® L40 Compact Fluorescent

Cat. No. Finish Mounting Ballast Input Wats Amps Lamps
8279ENWH Matte White/Metalized Louver All Lytespan Track Systems Electronic 78W .78AMP 2 Lt. 40W (22 1/2”) 8279ENWWH Matte White/White Louver DO NOT attach to stem mounted track Twin Tube Fluorescent 8279ENBK Matte Black/Metalized Louver (unless used with suspension beam PL-L 40W/RS by Phillips housing) or track mounted with swivel F40/30BX by GE stem (7480, 7481). FT40 DL/RS by Osram/Sylvania
Features 1. Attachment Fitting: Molded polycarbonate, pin rotates fitting to engage into track to energize fixture. 2. Brass Contact: Extends for connection to second circuit in Advent® Lytespan track. 3. Reflector: Specular Plus® finish.* 4. Body Housing: One-piece die-cast aluminum. 5. Pivot Tension Mount: 0° - 90° Vertical rotation from NADIR in both directions; (0° - 78° from NADIR when used with Recessed Track). 6. (2) Track Adaptor Housing: Die-cast aluminum. 7. Aiming Lock: Locks vertical position at the desired aiming angle. 8. Lamp Socket: High temperature thermoplastic. 9. Louver with Parabolic Blades: Snaps inside fixtures body. Molded ABS, semi-specular finish or integral white blades. 10.Lamp Support Clip (2): High temperature thermoplastic. 11.(2) 40W Twin Tube: Compact fluorescent lamp (by others). 12.Ballast: Electronic, 2 Lt. power factor greater than .99, light weight, harmonic distortion less than 10%. 13.Locking Knob: Mechanically locks fixture to the track, independently from the electrical connection. 14.Lever: Energizes fixture.
Finish All painted finishes baked enamel.
Labels UL, I.B.E.W.
* Specular Plus® is a registered trademark of MSC Laminates and Composites Inc. Advent® is a registered trademark of Lightolier.
Job Name:
Cat. No.:
Lamp(s):
Electrical Lampholder and ballast prewired with 105°C 18 ga. wire. Input voltage 120V.

Page 2 of 2 Lyteflood ® L40 Compact Fluorescent
FOOTCANDLES ON WALL:
59 f.c. 54 f.c.
59 f.c.
EXAMPLE: With track located 4' from wall and multiple units spaced 6' on center and aimed 45° from horizontal, the illumination on wall 4' from ceiling will be 59 f.c. beneath units and 54 f.c. between units.
0' 1' 2' 3' 4' 5'
Distance From Ceiling in Feet
1' 141 110 57 22 6 1
2' 127 108 71 39 19 9
3' 76 68 50 31 10 10
4' 45 42 34 24 15 9
5' 29 27 23 17 12 8
6' 19 19 16 13 10 7
7' 13 13 11 10 8 6
8' 9 9 8 7 6 5
9' 7 7 6 6 5 4
0' 1' 2' 3' 4' 5'
Distance From Ceiling in Feet
1' 80 69 47 27 14 7
2' 77 68 49 30 17 8
3' 61 56 44 31 20 11
4' 42 39 33 25 18 12
5' 28 27 23 19 14 10
6' 21 20 18 15 12 9
7' 15 14 13 11 9 7
8' 11 11 10 9 8 6
9' 9 9 8 7 6 5
Footcandles are average and rounded off and are based on a minimum of five units.