Lightolier 9476
目次 8セクション Lytespan ® Track Lighting System 9476 · Ordering Information · Lighting Data 2-54W T5 High Output · Footcandles on wall: · … 表示非表示
Page 1 of the Lightolier 9476 user manual — Ordering Information
1ページ · クリックして拡大
1ページ

Lytespan ® Track Lighting System 9476

Page 1 of 2 PowerWash™T5 4 Foot Track Mounted 54 Watt High Output Fluorescent

Lightolier 9476 — Lytespan ® Track Lighting System 9476 diagram (page 1)
図 1 · Lytespan ® Track Lighting System 9476

Ordering Information

Lightolier 9476 — Ordering Information diagram (page 1)
図 2 · Ordering Information

9476WH Matte White Compatible with all Lytespan® Track Systems. 2 x 54w T5 High Output (Fluorescent) 9476BK Matte Black Not compatible with ProSpec Track, Clamp-On 9476AL Metallic Aluminum Monopoint, Slope Ceiling Adapter or Extension 9477WH Matte White Wands. 1 x 54w T5 High Output (Fluorescent) 9477BK Matte Black 9477AL Metallic Aluminum

Features 1. Ballast & Reflector Housing: Aluminum with die-cast endcaps. 2. Ballast: 54w electronic. 3. Flood Reflector: Aluminum, with highly reflective and semispecular finish for a smooth wash of light. 4. Louver: Aluminum, for glare control, with captive locking springs for easy installation and removal. 5. Vertical Pivot: Die cast rotation housing with positive rotation stop provides 0° (NADIR) –130° vertical rotation in both directions. 6. Sockets: 600v rated mini bi-pin sockets with 90° rotor lock to engage contacts and retain with a positive detent. 7. Socket Bracket: Adjustable steel, mounting bracket slides out for easy lamping. 8. Attachment Fitting: Molded polycarbonate; pin rotates fitting into track to engage luminaire 9. Brass Contact: Extends for connection to second circuit in Advent®

Electrical Rapid Start High Power Factor, Class P Electronic Ballast Power Factor: >.97% Sound Rated: A Minimum Start Temp: 0°F Input Watts: 9476 117W 9477 59W

Finish All painted finishes are baked enamel.

Label UL, c.U.L.

Lytespan track. 10.Track Adapter Arm: Die-cast aluminum with integral polarity keyguard.

Advent® is a registered trademark of Lightolier.

Lightolier 9476 — Ordering Information diagram (page 1)
図 3 · Ordering Information
  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • B0902
Page 2 of the Lightolier 9476 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Lytespan ® Track Lighting System 9476

Page 2 of 2 PowerWash™T5 4 Foot Track Mounted 54 Watt High Output Fluorescent

Lighting Data 2-54W T5 High Output

Footcandles on wall:

Lightolier 9476 — Lighting Data 2-54W T5 High Output diagram (page 2)
図 4 · Lighting Data 2-54W T5 High Output

Lamp Information: 2 X 54W T5 High Output Mini Bi-Pin Fluorescent (9476) 1 x 54W T5 High Output Mini Bi Pin Fluorescent (9477)

Two Lamps, without louver,

aimed 45˚ up.

Two Lamps, with louver,

aimed 45˚ down.

EXAMPLE: With track located 4’ from wall and multiple units spaced 6’ on center and aimed 45˚ from horizontal, the illumination on wall 4’ from ceiling will be 79 f.c. beneath units and 70 f.c. between units.

One Lamp, with louver,

aimed 45˚ down.

Footcandles on Wall Track 3 Feet From Wall Single Unit Multiple Units

Lightolier 9476 — Footcandles on Wall Track 3 Feet From Wall Single Unit Multiple Units diagram (page 2)
図 5 · Footcandles on Wall Track 3 Feet From Wall Single Un…

231 184 231 180 150 180 124 112 124 97 92 97 57 55 57 47 46 47 31 31 31 22 22 22 18 18 18

218 127 218 168 106 168 112 84 112 87 74 87 49 44 49 41 38 41 27 26 27 19 18 19 16 15 16

1’ 198 176 118 60 28 14 2’ 158 142 90 52 24 10 3’ 103 94 69 41 22 10 4’ 68 63 49 33 20 12 5’ 40 38 30 22 14 8 6’ 26 25 21 16 12 8 7’ 17 16 14 11 8 6 8’ 11 11 10 8 6 5 9’ 8 8 7 6 5 4

263 258 263 209 206 209 149 148 149 116 116 116 71 71 71 56 56 56 38 38 38 27 27 27 22 22 22

Track 4 Feet From Wall Single Unit Multiple Units

Lightolier 9476 — Track 4 Feet From Wall Single Unit Multiple Units diagram (page 2)
図 6 · Track 4 Feet From Wall Single Unit Multiple Units

1’ 113 101 71 39 17 6 2’ 114 104 77 47 25 12 3’ 87 80 62 40 24 13 4’ 63 59 47 34 22 13 5’ 46 44 36 27 19 13 6’ 31 30 25 20 14 10 7’ 22 21 18 15 11 8 8’ 16 15 13 11 9 7 9’ 11 11 10 8 7 6

145 143 145 164 163 164 136 135 136 112 112 112 93 93 93 66 66 66 50 50 50 41 42 42 31 32 32

123 106 123 136 123 136 110 103 110 91 88 91 77 75 77 54 53 54 41 40 41 35 34 35 26 26 26

114 76 114 123 92 123 97 79 97 79 70 79 66 62 66 46 43 46 35 34 35 30 29 30 23 22 23

Track 5 Feet From Wall Single Unit Multiple Units

Lightolier 9476 — Track 5 Feet From Wall Single Unit Multiple Units diagram (page 2)
図 7 · Track 5 Feet From Wall Single Unit Multiple Units

1’ 81 75 59 40 25 15 2’ 83 77 61 42 27 16 3’ 75 70 57 41 28 18 4’ 55 52 43 32 23 15 5’ 42 40 34 27 19 14 6’ 33 31 27 22 17 12 7’ 25 24 21 17 14 11 8’ 18 17 15 13 10 8 9’ 13 13 12 10 9 7

140 139 140 147 147 147 143 143 143 109 109 109 89 89 89 76 76 76 62 62 62 46 46 46 39 39 39

115 109 115 121 116 121 118 115 118 89 87 89 73 71 73 62 61 62 51 50 51 37 37 38 32 32 32

102 86 102 107 93 107 104 94 104 76 71 76 62 59 62 53 51 53 44 42 44 32 31 32 27 27 27

Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • B0902
Show 9 more labels / short text on this page
180˚ 150˚ · 120˚ · 90˚ · 90˚ · 60˚ · 0˚ 30˚ · 90˚ · 60˚ · 0˚ 30˚
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier 9476について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier 9476に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier 9476 取扱説明書(PDF)

2 ページ·152 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…