JA
Lightolier logo
公式取扱説明書

Lightolier AGI

2 ページ·183 KB·インテリア家具・調度品·PDF·EN
Lightolier AGI
目次 25セクション Lighting Systems Agili-T Pendant Separate Direct/Indirect Optics AGI/AGV · Ordering information · AG · GR · … 表示非表示
Page 1 of the Lightolier AGI user manual — INDIVIDUAL CONTROL
1ページ · クリックして拡大
1ページ

Lighting Systems Agili-T Pendant Separate Direct/Indirect Optics AGI/AGV

Page 1 of 2 2 lamp T5UP, 1 lamp T5 DOWN per 4’ section

Lightolier AGI — Lighting Systems Agili-T Pendant Separate Direct/Indirect Optics AGI/AGV diagram (page 1)
図 1 · Lighting Systems Agili-T Pendant Separate Direct/Ind…
Lightolier AGI — Lighting Systems Agili-T Pendant Separate Direct/Indirect Optics AGI/AGV diagram (page 1)
図 2 · Lighting Systems Agili-T Pendant Separate Direct/Ind…

Ordering information

AG

P

GR

DI

UNV

PG

Lamp Qty in a cross

AGAgili-T

I: Direct-Indirect with Independent Compartments (Multiple Optics) & Parabolic Louver

4. 4’

P: Pendant

GRTitanium
DIDirect Power Feed

28: 28W T5

120: 120V

DWiGEN DALI Adressable T5/T5HO with Network-2 MultiSense Integral Motion Sensor (120 or 277V only)
3. 3 lamps (2 up, 1 down)
WHWhite

54: 54W T5HO

277: 277V

6 wires,4 wires for 347V only

347: 347V

UNVUniversal Voltage 120/277V

V: Direct-Indirect with Independant Compartments (Multiple Optics) and Flat Blade Louver.

DAiGEN DALI Adressable T5/T5HO (UNV only)
PGElectronic Program Start T5/T5HO
  • Features
  • 80.5% efficient (76% up / 24% down) using T5 technology (3x F28T5).
  • Separate optics for maximum control options.
  • Ultra-Light construction (4’ luminaire less than 15 lb / 6.8 kg) favors mobility, adds installation and remodeling convenience.
  • Wide indirect distribution for uniform ceiling luminance.
  • Built-in network connectors and wiring (Agili-T Network). Construction
  • Parabolic louver optic made of matte aluminum / Flat Blade optic incorporates a white finish
  • Unique contoured louver design with integral light stop Labels
  • Electrical
  • Standard product offering (DI version, 120V and 277V only) includes continuous 2-circuit wiring, one circuit for the upper compartment (if applicable) and one circuit for the lower compartment (if applicable). Single and double compartment luminaires can be mixed.
  • DA and DW available with Agili-T Network only.
  • Integrated quick connectors for power and network cable (Agili-T Network only) and auto plug-in connections between luminaires.
  • 18-gauge wire, maximum 10A per circuit. Mounting
  • Suspension points on module: every 4’ (4’ luminaire)
  • Fast installation using mounting clip for Standard T-bar and Slim T-bar or for Slot T-bar (see last page).
  • All canopy, suspension, power feed and mounting hardware included. Finish
  • Seamless color and texture finish between luminaire and end-caps.
  • Available with textured (white or titanium) high resistant powder-based coating. Options and accessories
  • Emergency circuiting

AGI-AGV features separate optics enabling the independent lighting control of upper and lower compartment.

INDIVIDUAL CONTROL

  • One circuit for AGI upper compartment controls 1 ballast and 2 T5/T5HO lamp for indirect lighting ( per 4’ of luminaire).
  • One circuit for AGI lower compartment controls 1 ballast and 1 T5/T5HO lamps for direct lighting ( per 4’ of luminaire).
  • Two ballasts allow independant control of compartments (e.g. uniform ceiling luminance and no direct light).
  • Separate dimming of compartments available with Agili-T Network version.
Lightolier AGI — INDIVIDUAL CONTROL diagram (page 1)
図 3

** If electrical junction box is needed to connect emergency wiring, order AGEB, AGES or AGEO. *** 18-gauge wire. Maximum of 10A per breaker. 2 circuits using 2 breakers with common neutral.

LIGHTOLIER A GENLYTE COMPANY www.lightolier.com TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595 631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131

CANLYTE www.canlyte.com 525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221 WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH © 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION) AGI-AGV-1

Show 12 more labels / short text on this page
Family · Type · Luminaire · Mounting · Housing Finish · Wiring · Lamp · Voltage · Ballast · Options · Length · section
Page 2 of the Lightolier AGI user manual — ZONE LUMENS
2ページ · クリックして拡大
2ページ

Lighting Systems Agili-T Pendant Separate Direct/Indirect Optics AGI/AGV

Page 2 of 2 2 lamp T5UP, 1 lamp T5 DOWN per 4’ section

Coplanar Solo Parabolic/Flat Blade Louver

Separate Optics

CANDLEPOWER CURVE

UPPER OPTIC Effi ciency92%

90° 90°

LOW OPTIC Effi ciency57%

90° 90°

Report No: LSCA752 Cat. No: AGI4PWHDI328UNVPG 3 x 28W T5 at 2610 lumens. Effi ciency 80.5%. Indirect Maximum Candela: 1471 cd Indirect Peak at 122.5°. Candela at Nadir: 675 cd

90° 90°

3 x 28W T-5 at 2610 lumens

CANDLEPOWER

COEFFICIENTS OF UTILIZATION

ZONE DEG 0 22.5 45 67.5 90

80 70 50 30 1070 Wall Reflectance 70 50 3050 10 50 30 10 0.81 0.75 0.72 0.69 0.66 0.68 0.63 0.59 0.55 0.63 0.56 0.51 0.47 0.58 0.5 0.44 0.4 0.53 0.44 0.38 0.34 0.49 0.4 0.34 0.29 0.45 0.36 0.3 0.25 0.41 0.32 0.26 0.22 0.38 0.29 0.23 0.190.72 0.72 0.72 0.66 0.64 0.62 0.61 0.56 0.53 0.56 0.5 0.46 0.51 0.45 0.4 0.47 0.4 0.35 0.43 0.36 0.31 0.4 0.32 0.27 0.37 0.29 0.24 0.34 0.26 0.210.72 0.55 0.55 0.55 0.59 0.49 0.48 0.46 0.5 0.44 0.41 0.39 0.42 0.39 0.36 0.34 0.36 0.35 0.32 0.29 0.31 0.31 0.28 0.25 0.27 0.28 0.25 0.22 0.23 0.25 0.22 0.19 0.2 0.23 0.19 0.17 0.18 0.21 0.17 0.14

0 675 5 683 676 682 686 670 15 638 641 621 631 626 25 552 530 612 729 767 35 475 465 631 733 748 45 341 407 507 522 533 55 163 221 238 202 156 65 34 40 37 52 56 75 4 2 0 0 3 85 0 90 95 19 155 144 115 112 105 169 507 689 700 704 115 352 542 1056 1235 1248 125 525 666 996 1355 1466 135 689 764 982 1176 1281 145 822 858 1027 1154 1170 155 929 967 1002 1108 1129 165 1003 1025 1052 1045 1048 175 1040 1039 1060 1061 1055 180 1040

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 98.2

Ordering instructions

DISTRIBUTION

% LAMP %LUMINAIRE 0-30 539 6.89 8.56 0-40 913 11.67 14.49 0-60 1451 18.54 23.03 0-90 1500 19.17 23.8 40-90 587 7.5 9.31 60-90 49 0.63 0.78 90-180 4804 61.36 76.2 0-180 6304 80.52 100

1. Single pendant luminaire: no continuous rows 2. Complete with suspension system including 2 canopies, 2 height-adjustable 36” length std. aircraft cables, 1 power feed/communications cable 3: Network ready luminaire featuring 2 extra communication wires 4: Comes with 6”-36” adjustable suspension

ZONE LUMENS

Job Information Type:

LIGHTOLIER A GENLYTE COMPANY www.lightolier.com TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595 631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131

CANLYTE www.canlyte.com 525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221 WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH © 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION)

Show 6 more labels / short text on this page
180° · 180° · 0° · 180° · 0° · 0°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier AGIについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier AGIに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier AGI 取扱説明書(PDF)

2 ページ·183 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…