Page 1 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Narrow Beam
3 1 10 6 5 9 8 4 2 11 7
20" (508 mm) to 30" (762 mm)
21-1/4" (540 mm) 175-250W 23-3/4" (603 mm) 320-400W
Ceiling Cutout: 12 9/16” (256 mm) Dia.
12" (305 mm) Dia.
2" (50 mm) max. Ceiling Thickness
13-1/4" (337 mm) Dia.
C12E28VN CLW Specular Clear, White Painted Flange. CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.
C1217MHPU Magnetic Pulse Start, 120V/277V 175W ED28, BT28, PS MH C1225MHPU Magnetic Pulse Start, 120V/277V 250W ED28, BT28, PS MH C1232MHPU Magnetic Pulse Start, 120V/277V 320W ED28, BT28, PS MH C1240MHPU Magnetic Pulse Start, 120V/277V 400W ED28, BT28, PS MH C1217MHU Magnetic, 120V/277V 175W ED28, BT28, MH C1225MHU Magnetic, 120V/277V 250W ED28, BT28, MH C1240MHU Magnetic, 120V/277V 400W ED28, BT28, MH
Features 1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides narrow beam optics ideal for high ceilings. Also available in wide beam, see C12E28VW specification sheet. 2. Aperture Cone: Low brightness with 40° cut-off to lamp. Specular Clear or Comfort Clear™ Diffuse, or champagne bronze self-flanged in painted white or aperture-matching polished flange. Consult factory for other finishes. 3. Lamp Shield: High-temperature glass as required by code, captive during re-lamping. 4. Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base porcelain socket with nickel plated screw shell. Postive locking attachment without tools to reflector assures proper optical alignment of lamp. 5. Mounting Frame: 0.048" (18-ga.) galvanized steel. Includes the pre-installed mounting bars. 6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 7. Retention Springs: Rust resistant springs secure cone for quick, tool-less installation. 8. Frame Vertical Adjustment: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using mounting bars (provided, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be preset prior to installation. 9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 10. Ballast: Pulse Start 11.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 12.Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Ballast ANSI Code Voltage Max. Amps Input Watts 175W PS MH M137 120/277 2.20/0.90 205 250W PS MH M138 120/277 2.80/1.20 290 320W PS MH M132 120/277 3.40/1.50 370 400W PS MH M135 120/277 4.10/1.80 465 175W MH M57 120/277 2.00/0.90 205 250W MH M58 120/277 2.60/1.10 290 400W MH M59 120/277 3.90/1.70 460
Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “E”. Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V). Chicago Plenum: Consult Factory.
Labels UL (Suitable for Damp Locations), CSA, I.B.E.W. For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to- center of adjacent luminaries; 3 inch from top of luminaire to overhead building member;2 feet from luminaire center to side building member.
Job Name:
Cat. No.:
Lamp(s):
Electrical Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature, Type 1 Outdoor rating.

Page 2 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Narrow Beam
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 35340 55 1009 65 0 75 0 85 0
0 .70 .69 .69 .66 .66 .63 .63 .59 1 .67 .66 .65 .64 .65 .63 .62 .61 .60 .59 .56 2 .65 .62 .60 .59 .61 .58 .59 .57 .58 .56 .53 3 .62 .59 .56 .54 .58 .54 .57 .53 .55 .52 .51 4 .60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .48 5 .57 .53 .50 .48 .52 .48 .51 .47 .50 .47 .46 6 .55 .50 .47 .45 .50 .45 .49 .45 .48 .44 .43 7 .52 .47 .44 .42 .47 .42 .46 .42 .46 .42 .41 8 .50 .45 .42 .40 .44 .40 .44 .40 .43 .39 .38 9 .48 .43 .40 .37 .42 .37 .42 .37 .41 .37 .36 10 .45 .40 .37 .35 .40 .35 .40 .35 .39 .35 .34 LUMINAIRE INPUT WATTS = 205.0
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 5166 40.05 67.87 0-40 6716 52.06 88.23 0-60 7612 59.01 100 0-90 7612 59.01 100 40-90 895 6.94 11.77 60-90 90-180-180 7612 59.01 100
** EFFICIENCY = 59.0% ** CERTIFIED TEST REPORT NO. 2506FR, DATE: MAR 14, 2004 SC = .5 COMPUTED BY LSI PROGRAM **TEST-LITE**
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 54956 55 2036 65 0 75 0 85 0
0 .71 .69 .69 .66 .66 .63 .63 .59 1 .68 .67 .65 .64 .65 .63 .63 .61 .61 .59 .57 2 .65 .63 .61 .59 .62 .58 .60 .57 .58 .56 .54 3 .62 .59 .57 .55 .58 .54 .57 .54 .56 .53 .51 4 .60 .56 .53 .51 .56 .51 .54 .50 .53 .50 .48 5 .57 .53 .50 .48 .53 .48 .52 .47 .51 .47 .46 6 .55 .51 .47 .45 .50 .45 .49 .45 .48 .44 .43 7 .52 .48 .45 .42 .47 .42 .47 .42 .46 .42 .41 8 .50 .45 .42 .40 .45 .40 .44 .40 .44 .39 .39 9 .48 .43 .40 .37 .42 .37 .42 .37 .41 .37 .36 10 .46 .40 .37 .35 .40 .35 .40 .35 .39 .35 .34 LUMINAIRE INPUT WATTS = 290.0
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 7828 40.2 67.57 0-40 10186 52.3 87.92 0-60 11585 59.49 100 0-90 11585 59.49 100 40-90 1398 7.18 12.08 60-90 90-180-180 11585 59.49 100
** EFFICIENCY = 59.5% ** CERTIFIED TEST REPORT NO. 2507FR, DATE: MAR 14, 2004 SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 49970 55 2444 65 0 75 0 85 0
0 .69 .67 .67 .64 .64 .62 .62 .58 1 .66 .65 .63 .62 .64 .61 .61 .59 .59 .58 .55 2 .63 .61 .59 .57 .60 .57 .58 .55 .56 .54 .52 3 .61 .57 .55 .53 .57 .53 .55 .52 .54 .51 .49 4 .58 .54 .52 .50 .54 .49 .53 .49 .51 .48 .47 5 .56 .51 .48 .46 .51 .46 .50 .46 .49 .45 .44 6 .53 .49 .46 .44 .48 .43 .47 .43 .47 .43 .42 7 .51 .46 .43 .41 .46 .40 .45 .40 .44 .40 .39 8 .48 .43 .40 .38 .43 .38 .42 .38 .42 .38 .37 9 .46 .41 .38 .36 .41 .36 .40 .35 .40 .35 .34 10 .44 .39 .36 .33 .38 .33 .38 .33 .38 .33 .32
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 11462 38.08 65.77 0-40 15159 50.36 86.98 0-60 17427 57.9 100 0-90 17428 57.9 100 40-90 2268 7.54 13.02 60-90 90-180-180 17428 57.9 100
** EFFICIENCY = 57.9% ** CERTIFIED TEST REPORT NO. 2364FR, DATE: FEB 10, 2004 SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 100565 55 982 65 0 75 0 85 0
0 .73 .71 .71 .68 .68 .65 .65 .61 1 .70 .69 .67 .66 .67 .65 .65 .63 .63 .61 .58 2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .58 .56 3 .64 .61 .59 .57 .60 .56 .59 .55 .57 .54 .53 4 .62 .58 .55 .53 .57 .53 .56 .52 .55 .52 .50 5 .59 .55 .52 .50 .54 .49 .53 .49 .52 .48 .47 6 .57 .52 .49 .47 .52 .47 .51 .46 .50 .46 .45 7 .54 .49 .46 .44 .49 .44 .48 .44 .47 .43 .42 8 .52 .47 .43 .41 .46 .41 .46 .41 .45 .41 .40 9 .49 .44 .41 .39 .44 .39 .43 .38 .43 .38 .37 10 .47 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 14575 41.64 67.88 0-40 18969 54.2 88.34 0-60 21472 61.35 100 0-90 21472 61.35 100 40-90 2503 7.15 11.66 60-90 90-180-180 21472 61.35 100
** EFFICIENCY = 61.4% ** CERTIFIED TEST REPORT NO. 2522FR, DATE: MAR 14, 2004 SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**