JA
Lightolier logo
公式取扱説明書

Lightolier C3MRGD

2 ページ·354 KB·インテリア家具・調度品·PDF·EN
Lightolier C3MRGD
目次 10セクション Calculite ® Evolution Glasslite Downlight C3MRGD · Page of 2 3" Aperture, MR16 (12V) · Non-IC Frame: C3LV C3LVE1 C3LVE2 · Non-IC AirSeal Frame: C3ALV C3ALVE1 C3ALVE2 · … 表示非表示
Page 1 of the Lightolier C3MRGD user manual — Trim Kit Frame-In Kit Lamp*
1ページ · クリックして拡大
1ページ

Calculite ® Evolution Glasslite Downlight C3MRGD

Page of 2 3" Aperture, MR16 (12V)

2 3 6 7 9 8 5

Non-IC Frame: C3LV C3LVE1 C3LVE2

1" (25mm) to 2 3/4" (70mm)

5" (127mm) Plus Ceiling

Non-IC AirSeal Frame: C3ALV C3ALVE1 C3ALVE2

Thk.

2" (59mm) Max. Ceiling Thk. 2 3/4" (70mm) Dia.

14 5/8" (372mm) IC AirSeal Frame: C3AICLV C3ALCLVE1

4" (102mm) Dia.

Ceiling Cutout: 3 1/2" (130mm) Dia. For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.

Trim Kit Frame-In Kit Lamp*

C3LV Non-IC Magnetic 120/277V 42W-65W MR16 (12V) C3LVE1 Non-IC Electronic 120V 20W-65W MR16 (12V) C3LVE2 Non-IC Electronic 277V 20W-65W MR16 (12V) C3ALV Non-IC AirSeal® Magnetic 120/277V 42W-65W MR16 (12V) C3ALVE1 Non-IC AirSeal® Electronic 120V 20W-65W MR16 (12V) C3ALVE2 Non-IC AirSeal® Electronic 277V 20W-65W MR16 (12V) C3AICLV IC AirSeal® Magnetic 120V 20W-50W MR16 (12V) C3AICLVE1 IC AirSeal® Electronic 120V 20W-50W MR16 (12V) Note: Magnetic not recommended for residential or noise sensitive areas.

Etch White Glasslite C3MRGD

Features 1. Glasslite: One piece borosilicate glass with interal flange, etched interior and white ceramic coated exterior. Etched white cone finish emits a subtie glow. Hinged, and snaps on for easy tool-less installation. Interchangeable with other 3" Evolution trims. Suitable for shower and other wet environments. 2. Lamp Support: Die-form aluminum with knurled surface for easy gripping during relamping. Spring tension clips hold lamp and lens and allow fast snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diameter accessories. 3. Cover Glass: High temperature, clear lens. 4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust trim kit vertically to accommodate up to 2" thick ceiling, lockable. 5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads. 6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim, matte black finish. 7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking features secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture. 8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping bars extend from 20" to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplified installation in 24"O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual- voltage, core & coil. Note: Magnetic not recommended for residential or noise sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, , EMI and circuit protections, thermal auto-reset, quiet operation. 10. Frame-In Kit: See Frame-In Kit specification sheets for more information. Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts of the luminaire and must not be placed above luminaire in a manner which will entrap heat. IC AirSeal - Luminaire may be in direct contact with thermal insulation.

Labels U.L. (Suitable For Wet Locations), I.B.E.W.; U.S. & Foreign Patents Pending *Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W

for ceiling thickness greater than 1" (up to 2").

Options and Accessories 2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets 2" dia. Louver: AL2HC Chicago Plenum: Consult Factory

Lightolier C3MRGD — Trim Kit Frame-In Kit Lamp* diagram (page 1)
図 1 · Trim Kit Frame-In Kit Lamp*
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • D1107
Show 16 more labels / short text on this page
12 5/8" (321mm) · 5" (127mm) · 14 3/8" (365mm) · Vertical Adjustment · 5 1/2" (140mm) · 9 5/8" (245mm) · 5" (127mm) · 14 3/8" (365mm) · 1/2" (13mm) · 10 1/8" (257mm) · 9" (229mm) · /16" mm) · 9 1/2" (242mm) · 9" (229mm) · 22 3/8" (568mm) · 1/2" (13mm) C3AICLV
Page 2 of the Lightolier C3MRGD user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® Evolution Glasslite Downlight C3MRGD

Page of 2 3" Aperture, MR16 (12V)

50W MR16 - 15° SPOT GE HALOGEN LAMP, LUMEN RATING = 750 LMS, 120V ELECTRONIC TRANSFORMER

ANGLE MEAN CP LUMENS 0 5551 5 3854 345 10 1184 15 310 138 20 141 25 48 30 30 22 35 8 7 40 5 45 2 2 50 1 55 2 1 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY CD. / SQ. M. ANGLE MEAN CD/SQ M 45 640 55 750 65 104 75 170 85 0

Coefficients of Utilization

80%70%50%30% 50 30 10 5010 5010 5010 0 Z onal Cavity Method- Effective Floor Cavity Reflectance =20% .83 .81 .80 .79 .78 .79 .79 .76 .75 .78 .76 .74 .73 .77 .74 .72 .71 .75 .73 .71 .69 .74 .72 .70 .68 .73 .71 .69 .67 .73 .70 .68 .67 .72 .69 .67 .66.81 .81 .79 .77 .76 .74 .75 .72 .74 .70 .72 .69 .71 .68 .70 .67 .69 .66 .68 .66.77 .77 .76 .75 .74 .73 .73 .71 .72 .70 .71 .69 .70 .68 .69 .67 .69 .66 .68 .65.74 .74 .73 .73 .73 .71 .72 .70 .71 .69 .70 .68 .70 .67 .69 .66 .68 .66 .68 .65.70 .69 .69 .68 .68 .67 .66 .66 .65 .65

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 512 68.32 97.99 0-40 518 66.20 99.25 0-60 522 69.64 99.89 0-90 522 69.72 100.00 40-90 3 0.52 0.75 60-90 0 0.08 0.11 90-180 0 0.00 0.00 0-180 522 69.72 100.00

** EFFICIENCY = 69.7% ** CERTIFIED TEST REPORT NO. 2724FR DATE: SEP 7, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

SC = .2

LUMINAIRE INPUT WATTS = 51

50W MR16 - 25° NARROW FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER

ANGLE MEAN CP LUMENS 0 1816 5 1629 150 10 1213 15 792 231 20 460 25 194 107 30 74 35 27 21 40 8 45 5 4 50 4 55 3 3 60 3 65 2 2 70 2 75 1 1 80 1 85 0 0 90 0

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M. ANGLE MEAN CD/SQ M 45 1483 55 1270 65 1241 75 1079 85 351

80%70%50%30% 50 30 10 5010 5010 5010 0 Z onal Cavity Method- Effective Floor Cavity Reflectance =20% .77 .75 .74 .73 .72 .73 .71 .70 .68 .71 .69 .67 .65 .70 .67 .64 .63 .68 .65 .62 .60 .66 .63 .61 .59 .65 .61 .59 .57 .63 .60 .57 .56 .62 .58 .56 .54.76 .76 .73 .71 .70 .67 .68 .65 .66 .62 .64 .60 .62 .59 .61 .57 .59 .56 .58 .54.72 .72 .70 .69 .68 .66 .66 .64 .65 .62 .63 .60 .62 .58 .60 .57 .59 .55 .57 .54.69 .69 .68 .67 .66 .64 .65 .63 .64 .61 .62 .59 .61 .58 .59 .56 .58 .55 .57 .54.65 .64 .62 .61 .60 .58 .57 .56 .54 .53

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 487 60.97 93.72 0-40 509 63.64 97.83 0-60 516 64.55 99.23 0-90 520 65.05 100.00 40-90 11 1.41 2.17 60-90 4 0.50 0.77 90-180 0 0.00 0.00 0-180 520 65.05 100.00

** EFFICIENCY = 65.1% ** CERTIFIED TEST REPORT NO. 2817FR DATE: SEP 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

SC = .5

LUMINAIRE INPUT WATTS = 51

50W MR16 - 40° FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER

Coefficients of Utilization

CEILING WALL 7080%70%50%30% 50 30 10 5010 5010 5010 0 RCRZ onal Cavity Method -Effective Floor Cavity Reflectance =20% 0 1 2 3 4 5 6 7 8 9.81 .79 .78 .77 .75 .76 .75 .73. 71 .75 .72 .70 .68 .73 .70 .68 .66 .71 .68 .65 .64 .70 .66 .64 .62 .68 .64 .62 .60 .67 .63 .60 .59 .65 .61 .59 .57.79 .79 .76 .74 .73 .71 .71 .68 .69 .66 .67 .63 .66 .62 .64 .60 .62 .59 .61 .57.76 .76 .73 .72 .71 .69 .70 .67 .68 .65 .66 .63 .65 .62 .63 .60 .62 .58 .60 .57.72 .72 .71 .70 .69 .68 .68 .66 .67 .64 .65 .62 .64 .61 .63 .60 .61 .58 .60 .57.66 .67 .65 .64 .63 .61 .60 .59 .57 .56 ** EFFICIENCY = 68% ** CERTIFIED TEST REPORT NO. 2722FR DATE: SEP 5, 2004 SC = .6 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • D1107
Show 17 more labels / short text on this page
CANDLEPOWER Distribution · 60˚ 1400˚ · 2800˚ · 4200˚ · 5600˚ · 30˚ · CANDLEPOWER Distribution · 500˚ · 60˚ · 1000˚ · 1500˚ · 2000˚ · 30˚ · CANDLEPOWER Distribution · 750˚ · 1125˚ · 1500˚
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C3MRGDについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C3MRGDに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C3MRGD 取扱説明書(PDF)

2 ページ·354 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…