JA
Lightolier logo
公式取扱説明書

Lightolier C3MRL

2 ページ·451 KB·インテリア家具・調度品·PDF·EN
Lightolier C3MRL
目次 4セクション Calculite ® Evolution Lensed Wall Washer C3MRL · Page of 2 3" Aperture, MR16 (12V) · Trim Kit Frame-In Kit Lamp* · Job Information Type: 表示非表示
Page 1 of the Lightolier C3MRL user manual — Trim Kit Frame-In Kit Lamp*
1ページ · クリックして拡大
1ページ

Calculite ® Evolution Lensed Wall Washer C3MRL

Page of 2 3" Aperture, MR16 (12V)

6 7 9 8 4 2 3 5

Non-IC FrameC3LV C3LVE1 C3LVE2

1" (25mm) to 2 3/4" (70mm)

5" (127mm) Plus Ceiling

Non-IC AirSeal FrameC3ALV C3ALVE1 C3ALVE2

Thk.

2" (59mm) Max. Ceiling Thk. 2 7/8" (73mm) Dia.

IC AirSeal FrameC3AICLV C3ALCLVE1

4" (102mm) Dia.

Flangeless Trim with Plaster Ring Accessory

3 3/8" (86mm) Dia.

Ceiling Cutout: 3 1/2" (130mm) Dia. For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.

Trim Kit Frame-In Kit Lamp*

Cone Finish White Flange Polished Flange Flangeless Clear C3MRL CLW C3MRL CLP C3MRL CLFT Comfort Clear Diffuse C3MRL CCDW C3MRL CCDP C3MRL CCDFT Champagne Bronze C3MRL CCZW C3MRL CCZP C3MRL CCZFT Gold C3MRL GDW C3MRL GDP C3MRL GDFT Matte White C3MRL WHW NA C3MRL WHFT Specular Black C3MRL BKW C3MRL BKP C3MRL BKFT

C3LV Non-IC Magnetic 120/277V 42W-65W MR16 (12V) C3LVE1 Non-IC Electronic 120V 20W-65W MR16 (12V) C3LVE2 Non-IC Electronic 277V 20W-65W MR16 (12V) C3ALV Non-IC AirSeal® Magnetic 120/277V 42W-65W MR16 (12V) C3ALVE1 Non-IC AirSeal® Electronic 120V 20W-65W MR16 (12V) C3ALVE2 Non-IC AirSeal® Electronic 277V 20W-65W MR16 (12V) C3AICLV IC AirSeal® Magnetic 120 20W-50W MR16 (12V) C3AICLVE1 IC AirSeal® Electronic 120V 20W-50W MR16 (12V) Note: Magnetic not recommended for residential or noise sensitive areas.

Features 1. Trim Kit: Low brightness aperture cone; 0.040" aluminum, anodized; 50° visual cut-off to lamp and lamp image. Cone keyed to kick reflector with direction spread lens distribute light smoothly for vertical surface wall washing. Captive lens during relamping. Hinged, and snaps on for easy tool-less installation. Self-flange in painted white or aperture matching polished flange. Flangeless trim used with Plaster Trim Ring accessory. Interchangeable with other 3" Evolution trims. 2. Lamp Support: Die-form aluminum with knurled surface for easy gripping during relamping. Spring tension clips hold lamp and lens and allow fast snap-in, snap-out relamping. Matte black finish. Accepts up to two 1" diam eter accessories. 3. Cover Glass: High temperature, soft focus lens. 4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust trim kit vertically to accommodate up to 2" thick ceiling, lockable. 5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads. 6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim, matte black finish. 7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking features secures all adjust ments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture. 8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescop ing bars extend from 20" to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self- centering feature simplified installation in 24"O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual- voltage, core & coil. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.

Features (continued) 10. Frame-In Kit: See Frame-In Kit specification sheets for more information. Non-IC and Non-IC AirSeal® - Insulation must be kept 3" away from any parts of the luminaire and must not be placed above luminaire in a manner which will entrap heat. IC AirSeal® - Luminaire may be in direct contact with thermal insulation.

Labels U.L. (Suitable For Wet Locations), I.B.E.W.; U.S. & Foreign Patents Pending *Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W for ceiling thickness greater than 1" (up to 2").

Options and Accessories 2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets 2" Dia. Louver: AL2HC Plaster Trim Ring (use with flangeless trim): CA3FMR Chicago Plenum: Consult Factory

Lightolier C3MRL — Trim Kit Frame-In Kit Lamp* diagram (page 1)
図 1 · Trim Kit Frame-In Kit Lamp*
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • E1107
Show 17 more labels / short text on this page
12 5/8" (321mm) · 5" (127mm) · 14 3/8" (365mm) · Vertical Adjustment · 5 1/2" (140mm) · 9 5/8" (245mm) · 5" (127mm) · 14 3/8" (365mm) · 10 1/8" (257mm) · 14 5/8" (372mm) · 1/2" (13mm) · 11 3/16" (284mm) · 9" (229mm) · 9" (229mm) · 9 1/2" (242mm) · 22 3/8" (568mm) · 1/2" (13mm) C3AICLV
Page 2 of the Lightolier C3MRL user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® Evolution Lensed Wall Washer C3MRL

Page of 2 3" Aperture, MR16 (12V)

Lightolier C3MRL — Calculite ® Evolution Lensed Wall Washer  C3MRL diagram (page 2)
図 2 · Calculite ® Evolution Lensed Wall Washer C3MRL

Example: With multiple units located 2’ from wall and 2’ on center, the illumination on the wall 3'‑down from the ceiling is 24 f.c. beneath and 23 f.c. between fixtures.

37W MR16 IR - 40˚ FLOOD SYLVANIA HALOGEN LAMP, LUMEN RATING = 840 LMS., 120V electronic TRANSFORMER CL FINISH REFLECTOR, REPORT NO. 2774FR

Multiple Units - Footcandles On Wall 2' from Wall - 2' On Center

Multiple Units - Footcandles On Wall 2' from Wall - 3' On Center

Multiple Units - Footcandles On Wall 3' from Wall - 3' On Center

Lightolier C3MRL — Calculite ® Evolution Lensed Wall Washer  C3MRL diagram (page 2)
図 3 · Calculite ® Evolution Lensed Wall Washer C3MRL

1 2.8 2.5 2.8 2 7.3 6.7 7.3 3 11.9 11.3 11.9 4 13.1 12.8 13.1 5 11.8 11.6 11.8 6 10.3 10.2 10.3 7 8.5 8.4 8.5 8 7.2 7.1 7.2 9 6.1 6.1 6.1 10 5.4 5.3 5.4 11 4.8 4.8 4.8 12 4.5 4.5 4.5 13 4.2 4.2 4.2 14 4.2 4.1 4.2

1 2.2 1.4 2.2 2 6.0 3.6 6.0 3 8.9 6.8 8.9 4 9.3 8.2 9.3 5 8.2 7.6 8.2 6 7.1 6.8 7.1 7 5.8 5.6 5.8 8 4.9 4.8 4.9 9 4.2 4.1 4.2 10 3.6 3.6 3.6 11 3.3 3.3 3.3 12 3.0 3.0 3.0 13 2.9 2.9 2.9 14 2.8 2.8 2.8

1 1.2 1.1 1.2 2 2.0 1.7 2.0 3 3.4 3.1 3.4 4 5.1 4.7 5.1 5 6.0 5.8 6.0 6 6.2 6.0 6.2 7 5.9 5.8 5.9 8 5.5 5.4 5.5 9 5.0 4.9 5.0 10 4.5 4.5 4.5 11 4.1 4.1 4.1 12 3.8 3.7 3.8 13 3.5 3.5 3.5 14 3.4 3.4 3.4

Distance From Ceiling in Feet

Distance From Ceiling in Feet

Downlight Wall Wash Side Side

50W MR16 - 40˚ FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS., 120V electronic TRANSFORMER CL FINISH REFLECTOR, REPORT NO. 2816FR Multiple Units - Footcandles On Wall 2' from Wall - 2' On Center

Multiple Units - Footcandles On Wall 2' from Wall - 3' On Center

Multiple Units - Footcandles On Wall 3' from Wall - 3' On Center

1 3.8 3.4 3.8 2 9.8 8.9 9.8 3 16.0 15.1 16.0 4 17.6 17.1 17.6 5 15.8 15.5 15.8 6 13.8 13.6 13.8 7 11.4 11.3 11.4 8 9.6 9.5 9.6 9 8.2 8.2 8.2 10 7.2 7.2 7.2 11 6.5 6.5 6.5 12 6.0 6.0 6.0 13 5.7 5.7 5.7 14 5.6 5.6 5.6

1 3.0 2.0 3.0 2 8.1 4.8 8.1 3 11.9 9.1 11.9 4 12.5 10.9 12.5 5 10.9 10.2 10.9 6 9.5 9.1 9.5 7 7.8 7.5 7.8 8 6.5 6.4 6.5 9 5.6 5.5 5.6 10 4.9 4.8 4.9 11 4.4 4.4 4.4 12 4.1 4.0 4.1 13 3.8 3.8 3.8 14 3.8 3.8 3.8

1 1.6 1.5 1.6 2 2.7 2.3 2.7 3 4.6 4.2 4.6 4 6.8 6.4 6.8 5 8.1 7.8 8.1 6 8.3 8.0 8.3 7 7.9 7.7 7.9 8 7.3 7.2 7.3 9 6.7 6.6 6.7 10 6.0 6.0 6.0 11 5.5 5.4 5.5 12 5.0 5.0 5.0 13 4.7 4.7 4.7 14 4.5 4.5 4.5

Distance From Ceiling in Feet

Distance From Ceiling in Feet

Distance From Ceiling in Feet

Downlight Wall Wash Side Side

50W MR16 - 40˚ FLOOD SYLVANIA HALOGEN LAMP, LUMEN RATING = 1125 LMS., 120V electronic TRANSFORMER CL FINISH REFLECTOR, REPORT NO. 2700FR Multiple Units - Footcandles On Wall 2' from Wall - 2' On Center

Multiple Units - Footcandles On Wall 2' from Wall - 3' On Center

Multiple Units - Footcandles On Wall 3' from Wall - 3' On Center

Lightolier C3MRL — Calculite ® Evolution Lensed Wall Washer  C3MRL diagram (page 2)
図 4 · Calculite ® Evolution Lensed Wall Washer C3MRL

1 3.7 3.3 3.7 2 9.8 8.9 9.8 3 15.9 15.1 15.9 4 17.5 17.1 17.5 5 15.8 15.5 15.8 6 13.8 13.6 13.8 7 11.3 11.2 11.3 8 9.6 9.5 9.6 9 8.2 8.1 8.2 10 7.2 7.1 7.2 11 6.4 6.4 6.4 12 5.9 5.9 5.9 13 5.6 5.6 5.6 14 5.6 5.5 5.6

1 3.0 1.9 3.0 2 8.0 4.8 8.0 3 11.9 9.1 11.9 4 12.5 10.9 12.5 5 10.9 10.1 10.9 6 9.4 9.0 9.4 7 7.7 7.5 7.7 8 6.5 6.4 6.5 9 5.5 5.5 5.5 10 4.8 4.8 4.8 11 4.3 4.3 4.3 12 4.0 4.0 4.0 13 3.8 3.8 3.8 14 3.7 3.7 3.7

1 1.6 1.4 1.6 2 2.7 2.3 2.7 3 4.6 4.2 4.6 4 6.8 6.3 6.8 5 8.0 7.7 8.0 6 8.2 8.0 8.2 7 7.8 7.7 7.8 8 7.3 7.1 7.3 9 6.6 6.5 6.6 10 6.0 5.9 6.0 11 5.4 5.4 5.4 12 5.0 4.9 5.0 13 4.7 4.6 4.7 14 4.5 4.4 4.5

Distance From Ceiling in Feet

Distance From Ceiling in Feet

Downlight Wall Wash Side Side

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • E1107
Show 13 more labels / short text on this page
CANDLEPOWER Distribution · 3' · 3' · CANDLEPOWER Distribution · 2' · 3' · 3' · 60° 150 · 30° · 30˚ · CANDLEPOWER Distribution · 3' · 3'
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C3MRLについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C3MRLに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C3MRL 取扱説明書(PDF)

2 ページ·451 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…