JA
Lightolier logo
公式取扱説明書

Lightolier C3MRPD

2 ページ·369 KB·インテリア家具・調度品·PDF·EN
Lightolier C3MRPD
目次 10セクション Calculite ® Evolution Pinhole Downlight C3MRPD · Page 1 of 2 1 1/4" Aperture, MR16 (12V) · Lightolier is a Philips group brand · Page 2 of 2 1 1/4" Aperture, MR16 (12V) · … 表示非表示
Page 1 of the Lightolier C3MRPD user manual — Lightolier is a Philips group brand
1ページ · クリックして拡大
1ページ

Calculite ® Evolution Pinhole Downlight C3MRPD

Page 1 of 2 1 1/4" Aperture, MR16 (12V)

Lightolier C3MRPD — Calculite ® Evolution Pinhole Downlight C3MRPD diagram (page 1)
図 1 · Calculite ® Evolution Pinhole Downlight C3MRPD

2 3 6 7

Lightolier C3MRPD — Calculite ® Evolution Pinhole Downlight C3MRPD diagram (page 1)
図 2 · Calculite ® Evolution Pinhole Downlight C3MRPD

Flangeless Trim with Plaster Ring Accessory 9 1/2" (242mm)

Trim KitFrame-In KitLamp* Trim PlateC3LVNon-ICMagnetic 120/277V42W-65W MR16 (12V) Baffle FinishPainted White Satin AluminumFlangelessC3LVE1Non-ICElectronic 120V20W-65W MR16 (12V) Matte WhiteC3MRPD WHNAC3MRPD WHFTC3LVE2Non-ICElectronic 277V20W-65W MR16 (12V) Matte BlackC3MRPD BKNAC3MRPD BKFTC3ALVNon-IC AirSeal®Magnetic 120/277V42W-65W MR16 (12V) Satin AluminumNA C3MRPD SAC3MRPD SAFT C3ALVE1 Non-IC AirSeal® Electronic 120V 20W-65W MR16 (12V) C3ALVE2 Non-IC AirSeal® Electronic 277V 20W-65W MR16 (12V) C3AICLV IC AirSeal® Magnetic 120V 20W-50W MR16 (12V) C3AICLVE1 IC AirSeal® Electronic 120V 20W-50W MR16 (12V) Note: Magnetic not recommended for residential or noise sensitive areas.C3ALVE1Non-IC AirSeal®Electronic 120V20W-65W MR16 (12V) C3ALVE2Non-IC AirSeal®Electronic 277V20W-65W MR16 (12V) C3AICLVIC AirSeal®Magnetic 120V20W-50W MR16 (12V) C3AICLVE1IC AirSeal®Electronic 120V20W-50W MR16 (12V)

Features 1. Trim Kit Baffle/Trim Plate: One piece machined aluminum, sharp details for clean look. 1 1/4" dia. miniature baffle and built-in aperture sheld minimize and blocks view into fixture. Keyed to lamp support assembly for true aiming of lamp to prevent incorrect installation of cone. Hinged, and snaps on for easy tool-less installation. Trim plate in painted white or anodized satin aluminum. Flangeless trim (reduced trim plate for miniature appearance) used with Plaster Trim Ring accessory. Interchangeable with other 3" Evolution trims. 2. Lamp Support: Die-form aluminum with knurled surface for easy gripping during relamping. Spring tension clips hold lamp and lens and allow fast snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diameter accessories. 3. Cover Glass: High temperature, soft focus lens. 4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust trim kit vertically to accommodate up to 2" thick ceiling, lockable. 5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads. 6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim, matte black finish. 7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking features secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture. 8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping bars extend from 20" to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self- centering feature simplified installation in 24"O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual- voltage, core & coil. Note: Magnetic not recommended for residential or noise sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.

Features (cont.) 10. Frame-In Kit: See Frame-In Kit specification sheets for more information. Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts of the luminaire and must not be placed above luminaire in a manner which will entrap heat. IC AirSeal - Luminaire may be in direct contact with thermal insulation.

Label U.L. (Suitable For Damp Locations), I.B.E.W.; U.S. & Foreign Patents Pending *Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W for ceiling thickness greater than 1" (up to 2").

Options and Accessories 2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets 2" Dia. Louver: AL2HC Plaster Trim Ring (use with flangeless trim): CA3FMR Chicago Plenum: Consult Factory

Lightolier C3MRPD — Calculite ® Evolution Pinhole Downlight C3MRPD diagram (page 1)
図 3 · Calculite ® Evolution Pinhole Downlight C3MRPD
  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • F0408

Lightolier is a Philips group brand

5 1/2" (140mm) · 1/2" (13mm) C3AICLV

Page 2 of the Lightolier C3MRPD user manual — Lightolier is a Philips group brand
2ページ · クリックして拡大
2ページ

Calculite ® Evolution Pinhole Downlight C3MRPD

Page 2 of 2 1 1/4" Aperture, MR16 (12V)

37W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 840 LMS, 120V Electronic Transformer

ANGLE MEAN CP LUMENS 0 1524 5 1350 126 10 1069 15 813 225 20 485 25 139 91 30 24 35 7 6 40 1 45 0 0 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY CD. / SQ.M. ANGLE MEAN CD/SQ M 45 0 55 0 65 0 75 0 85 0

Coefficients of Utilization

CEILING WALL80%70%50%30% 70 50 30 1050 1050 1050 100 RCRZonal Cavity Method- Effective Floor Cavity Reflectance =20% 0 1 2 3 4 5 6 7 8 9.64 .62 .61 .60 .60 .60 .59 .58 .57 .59 .57 .56 .54 .58 .56 .54 .53 .57 .54 .52 .51 .56 .53 .51 .50 .54 .52 .50 .49 .53 .50 .49 .48 .52 .49 .48 .46.62 .62 .60 .59 .58 .56 .56 .54 .55 .52 .54 .51 .53 .50 .51 .48 .50 .47 .49 .46.59 .59 .58 .57 .56 .55 .55 .53 .54 .52 .53 .50 .52 .49 .51 .48 .50 .47 .49 .46.57 .57 .56 .55 .55 .54 .54 .52 .53 .51 .52 .50 .51 .49 .50 .48 .49 .47 .48 .46.54 .53 .52 .51 .50 .49 .48 .47 .46 .46

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 442 52.70 98.47 0-40 448 53.42 99.81 0-60 449 53.51 99.97 0-90 449 53.52 100.00 40-90 0 0.10 0.19 60-90 0 0.01 0.03 90-180 0 0.00 0.00 0-180 449 53.52 100.00

** EFFICIENCY = 53.5% ** CERTIFIED TEST REPORT NO. 2739FR DATE: SEPT 24, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

SC = .5

LUMINAIRE INPUT WATTS = 38

50W MR16 IR - 40° Flood GE Halogen Lamp, Lumen Rating = 800 LMS, 120V Electronic Transformer

ANGLE MEAN CP LUMENS 0 1391 5 1364 128 10 1234 15 944 259 20 539 25 166 104 30 31 35 7 7 40 2 45 0 0 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ.M. ANGLE MEAN CD/SQ M 45 0 55 0 65 0 75 0 85 0

CEILING WALL80%70%50%30% 70 50 30 1050 1050 1050 100 RCRZonal Cavity Method- Effective Floor Cavity Reflectance =20% 0 1 2 3 4 5 6 7 8 9.74 .72 .71 .70 .70 .70 .69 .67 .66 .69 .67 .65 .63 .67 .65 .63 .61 .66 .63 .61 .59 .65 .62 .59 .58 .63 .60 .58 .56 .62 .59 .57 .56 .61 .57 .55 .54.73 .73 .70 .68 .68 .65 .66 .63 .64 .61 .62 .59 .61 .58 .60 .56 .58 .55 .57 .54.69 .69 .68 .66 .66 .64 .64 .62 .63 .60 .61 .59 .60 .57 .59 .56 .58 .55 .57 .54.66 .66 .65 .64 .64 .63 .63 .61 .62 .60 .61 .58 .60 .57 .58 .56 .57 .55 .56 .53.62 .62 .60 .60 .58 .57 .56 .55 .54 .53

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 491 61.43 98.34 0-40 498 62.36 99.83 0-60 499 62.45 99.97 0-90 499 62.47 100.00 40-90 0 0.11 0.17 60-90 0 0.02 0.03 90-180 0 0.00 0.00 0-180 499 62.47 100.00

** EFFICIENCY = 62.5% ** CERTIFIED TEST REPORT NO. 2720FR DATE: SEPT 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

SC = .6

LUMINAIRE INPUT WATTS = 51

50W MR16 IR - 40° Flood Sylvania Halogen Lamp, Lumen Rating = 1125 LMS, 120V Electronic Transformer

ANGLE MEAN CP LUMENS 0 2041 5 1808 169 10 1433 15 1089 302 20 650 25 186 122 30 33 35 9 8 40 2 45 1 1 50 1 55 1 1 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY CD. / SQ.M. ANGLE MEAN CD/SQ M 45 0 55 0 65 0 75 0 85 0

Coefficients of Utilization

CEILING WALL80%70%50%30% 70 50 30 1050 1050 1050 100 RCRZonal Cavity Method -Effective Floor Cavity Reflectance =20% 0 1 2 3 4 5 6 7 8 9 10.64 .62 .61 .60 .60 .60 .59 .58 .57 .59 .57 .56 .54 .58 .56 .54 .53 .57 .54 .52 .51 .56 .53 .51 .50 .54 .52 .50 .49 .53 .50 .49 .48 .52 .49 .48 .46 .51 .48 .47 .45.62 .62 .60 .59 .58 .56 .56 .54 .55 .52 .54 .51 .53 .50 .51 .48 .50 .47 .49 .46 .48 .45.60 .60 .58 .57 .56 .55 .55 .53 .54 .52 .53 .50 .52 .49 .51 .48 .50 .47 .49 .46 .48 .45.57 .57 .56 .55 .55 .54 .54 .52 .51 .51 .52 .50 .51 .49 .50 .48 .49 .47 .48 .46 .48 .45.54 .53 .52 .51 .50 .49 .48 .47 .46 .46 .45

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 593 52.72 98.39 0-40 601 53.45 99.75 0-60 602 53.57 99.97 0-90 602 53.59 100.00 40-90 1 0.13 0.25 60-90 0 0.02 0.03 90-180 0 0.00 0.00 0-180 602 53.59 100.00

** EFFICIENCY = 53.6% ** CERTIFIED TEST REPORT NO. 2721FR DATE: SEPT 5, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

SC = .5

LUMINAIRE INPUT WATTS = 51

Job Informationv Type:

  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • F0408

Lightolier is a Philips group brand

Show 18 more labels / short text on this page
CANDLEPOWER Distribution · 60˚ 400˚ · 800˚ · 1200˚ · 1600˚ · 30˚ · CANDLEPOWER Distribution · 60˚ 375˚ · 750˚ · 1125˚ · 1500˚ · 30˚ · CANDLEPOWER Distribution · 60˚ 500˚ · 1000˚ · 1500˚ · 2000˚ · 30˚
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C3MRPDについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C3MRPDに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C3MRPD 取扱説明書(PDF)

2 ページ·369 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…