Page 1 of 2 4 1/2” Aperture A19/MB19/BT15 Reflector Trim
9 1/2" Dia.

* 7 3/4"min. is for up to 3/4" thick ceiling. 1 1/4" Max. Ceiling Thk. C4AWCLW / C4120 or C4AWCLW / C4A120
Features 1. Reflector: 16 ga. aluminum, 50° visual cutoff to lamp and lamp image. “Cut- window” in downlight reflector and kick reflector provide vertical surface wall washing. Inner reflector contours provide even downlighting. Available with painted white or polished flange. Interchangeable with other Evolution 4 1/2” line voltage trims. 2. Socket Harness: Spring tension clips snap into die-cast aluminum top at prefocused positions ensuring correct optical alignment. Medium base porce- lain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed, plug- in quick connector for power connection to junction box. 3. Frame-In-Kit: Compatible Frame-In Kits are listed above. See separate Frame-In Kit specification sheets for details. Non-IC and Non-IC AirSeal® - Insulation must be kept 3” away from fixture sides and wiring compartments, and must not be placed above fixture in a manner which will entrap heat. IC-AirSeal® - Fixture may be in direct contact with insulation.
Labels UL Listed (suitable for damp locations), I.B.E.W.
US Patent No. 5,957,573. Other US and Foreign Patents Pending.

Clear: CL Gold: GD White: WH Black: BK Pewter: CPW Comfort Clear Diffuse: CCD Champagne Bronze: CCZ

Page 2 of 2 4 1/2” Aperture A19/MB19/BT15 Reflector Trim
Lighting Data
Lighting Data
Example: With clear Alzak® and 100W A-19 units, located 2’ from wall and 3’ on center, (matching downlights 3’ on center), the illumination on the wall 3’ down from the ceiling is 20 f.c. beneath and 18 f.c. between fixtures.
3’ 2’ 3’
20 f.c. 18 f.c.
Footcandles on Wall From Multiple Units - Clear Alzak® with 100W A19
Distance from Ceiling, Ft.
1 24 22 24 20 12 20 19 6 19 2 35 35 35 26 21 26 24 12 24 3 29 28 29 20 18 20 18 11 18 4 24 24 24 16 17 16 13 11 13 5 19 19 19 12 13 12 9 10 9 6 15 15 15 10 10 10 7 9 7 7 12 12 12 9 8 9 6 7 6 8 10 10 10 7 7 7 5 5 5 9 8 9 8 6 6 6 5 5 5
3’ 4’ 5’ 6’
Distance from Ceiling, Ft.
1 5 4 5 4 2 4 4 2 4 4 1 4 2 15 14 15 12 10 12 11 7 11 11 4 11 3 16 16 16 13 11 13 11 8 11 11 6 11 4 14 14 14 11 10 11 9 8 9 9 6 9 5 12 12 12 10 9 10 8 7 8 7 5 7 6 11 11 11 8 9 8 7 7 7 6 5 6 7 10 9 10 7 7 7 6 6 6 5 5 5 8 6 6 6 5 5 5 4 5 4 9 7 7 7 6 5 6 4 5 4
Footcandle values are averaged and rounded off and are based on a minimum of five units. For 100W BT15, multiply footcandles by 0.8
COEFFICIENTS OF UTILIZATION
100W A19
% Effective Ceiling Cavity Reflectance
1 .62 .61 .59 .61 .60 .59 .59 .58 .57 .57 .56 .55 .55 .54 .53 2 .58 .56 .54 .57 .55 .53 .55 .53 .52 .53 .52 .51 .52 .51 .50 3 .54 .51 .49 .53 .51 .49 .52 .50 .48 .50 .49 .47 .49 .48 .47 4 .51 .48 .45 .50 .47 .45 .49 .46 .45 .48 .46 .44 .47 .45 .44 5 .47 .44 .42 .47 .44 .42 .46 .43 .42 .45 .43 .41 .44 .42 .40 6 .45 .41 .39 .44 .41 39 .43 .41 .38 .42 .40 .38 .42 .40 .38 7 .42 .38 .36 .41 .38 .36 .40 .38 .36 .40 .37 .35 .39 .37 .35 8 .39 .36 .34 .39 .36 .33 .38 .35 .33 .38 .35 .33 .37 .35 .33 9 .37 .33 .31 .36 .33 .31 .36 .33 .31 .35 .33 .31 .35 .32 .31 10 .35 .31 .29 .34 .31 .29 .34 .31 .29 .33 .31 .29 .33 .30 .29
.52 .49 .46 .43 .40 .37 .34 .32 .30 .28
Report 0840FR Efficiency = 56.0%
Downlight Spacing Ratio = 1.0
20% Floor Cavity Reflectance
For 100W BT15, multiply CU. by 0.75