6 5 4 3 2 1

*6" min. is for up to 3/4" thick ceiling.

Features 1. Reflector: 16 ga. aluminum, 50° visual cutoff to lamp and lamp image. Available with painted white or polished flange. Interchangeable with other Evolution 4 1/2" low voltage trims. 2. Lamp Support: Die-formed aluminum with spring tension clips to hold lamp and lens allowing fast snap-in, snap-out relamping from below. Matte black finish. Cover glass may be replaced with a color filter or lens accessory. 3. Cover Glass: High temperature, tempered glass. Perimeter frost. 4. Socket Harness: Porcelain bi-pin socket. Pre-wired with No. 18 Teflon® leads. 5. Power Harness: Provides power to transformer. 6. Frame-In Kit: Compatible Frame-In Kits are listed above. Non-IC and Non-IC AirSeal® - Insulation must be kept 3" away from fixture sides and wiring compartments, and must not be placed above fixture in a manner which will entrap heat. IC-AirSeal® - Fixture may be in direct contact with insulation. 7. Maximum Ceiling Thickness: 2"
Evolution 4" Trims with Non-IC and AIC Frames C4MRD 1 Secondary Color Lens or 1 Mixing Color Lens‑ or 1 Specialty Filter
Labels UL Listed (suitable for damp locations), I.B.E.W.
Teflon® is a registered trademark of E.I. DuPont. US Patent No. 5,957,573. Other US and Foreign Patents Pending.


Page 2 of 2 4 1/2" Aperture, MR16 Reflector Trim
SPACING RATIO = 0.5
CERTIFIED TEST REPORT NO. 0881FR COMPUTED BY LSI PROGRAM **TEST-LITE**
CERTIFIED TEST REPORT NO. 0931FR COMPUTED BY LSI PROGRAM **TEST-LITE**
RECESSED OPEN REFLECTOR DOWNLIGHT 4 1/2” DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR 73W MR16 PHILLIPS LAMP, 36 DEG. FL. LUMEN RATING = 1320 LMS.
RECESSED OPEN REFLECTOR DOWNLIGHT 4 1/2” DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR 50W MR16 GE, FL / 40 DEG. LUMEN RATING = 800 LMS.


ANGLE MEAN CP LUMENS 0 2098 5 1798 168 10 1364 15 987 281 20 625 25 283 156 30 154 35 85 57 40 37 45 13 12 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0 ZONAL LUMENS AND PERCENTAGES
ANGLE MEAN CP LUMENS 0 2410 5 2287 214 10 1973 15 1552 432 20 1016 25 423 241 30 223 35 115 79 40 52 45 17 17 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0 ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP % LUMINAIRE 0-30 605 75.64 89.76 0-40 661 82.74 98.19 0-60 674 84.27 100.00 0-90 674 84.27 100.00 40-90 12 1.52 1.81 60-90 0 .00 .00 90-180 0 .00 .00 0-180 674 84.27 100.00
ZONE LUMENS % LAMP % LUMINAIRE 0-30 886 67.17 90.23 0-40 965 73.17 98.29 0-60 982 74.44 100.00 0-90 982 74.45 100.00 40-90 16 1.27 10.71 60-90 0 .00 .00 90-180 0 .00 .00 0-180 982 74.45 100.00
**EFFICIENCY =74.4% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES
THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 30 10 0 % WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .85 .83 .82 .83 .82 .81 .80 .79 .78 .77 .77 .76 .75 .74 . 74 .73 2 .81 .79 .77 .80 .78 .76 .77 .76 .75 .75 .74 .73 .73 . 73 .72 .71 3 .78 .76 .74 .77 .75 .73 .75 .74 .72 .74 .72 .71 .72 .71 .70 .69 4 .75 . 73 .71 .75 .72 .70 .73 .71 .69 .72 .70 .69 .71 .69 .68 .67 5 .73 .70 .68 .72 .69 .68 .71 .69 .67 .70 .68 .66 .69 .67 .66 .65 6 .71 .68 .66 .70 .67 .66 .69 .67 .65 .68 .66 .65 .67 .66 .64 .64 7 .68 .65 .63 .68 .65 .63 .67 .65 .63 .66 .64 .63 .66 .64 .62 .62 8 .66 .63 .61 .65 .63 .61 .65 .63 .61 .65 .62 .61 .64 .62 .60 .60 9 .64 .61 .59 .64 .61 .59 .63 .61 .59 .63 .60 .59 .62 .60 .59 .58 10 .62 .60 .57 .62 .60 .57 .61 .59 .57 .61 .59 .57 .61 .59 .57 .56 20% FLOOR CAVITY REFLECTANCE
80 70 50 30 10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .96 .94 .93 .94 .93 .92 .91 .90 .89 .88 .87 .86 .85 .84 .84 .82
2 .92 .90 .88 .90 .88 .87 .88 .86 .85 .85 .84 .83 .83 .82 .81 .80
3 .88 .86 .84 .87 .85 .83 .85 .83 .82 .84 .82 .80 .82 .81 .79 .78 4 .85 .83 .80 .85 .82 .80 .83 .81 .79 .81 .79 .78 .80 .78 .77 .76 5 .83 .79 .77 .82 .79 .77 .80 .78 .76 .79 .77 .75 .78 .76 .75 .74 6 .80 .77 .75 .80 .77 .74 .78 .76 .74 .77 .75 .74 .77 .75 .73 .72 7 .78 .74 .72 77 .74 .72 .76 .73 .72 .75 .73 .71 .75 .72 .71 .70 8 .75 .72 .70 .74 .72 .70 .74 .71 .69 .73 .71 .69 .73 .70 .69 .68 9 .73 .70 .68 .73 .70 .68 .72 .69 .67 .71 .69 .67 .71 .69 .67 .66 10 .71 .68 .66 .71 .68 .65 .70 .67 .65 .70 .67 .65 .69 .67 .65 .64
20% FLOOR CAVITY REFLECTANCE Conversion Factors: 20W to 50W MR16 FL: Clear, C.U.x 1.00: Diffuse / Gold, C.U.x 0.95.