Features 1. Trim Kit Aperture Cone: 50° visual cut-off to lamp and lamp image. Low brightness, 0.040” aluminum, anodized; keyed to lamp support assembly for true aiming of lamp to prevent incorrect installation of cone. Hinged and snaps on for easy tool-less installation. 2. Lamp Support: Die-form aluminum with knurled surface for easy gripping during relamping. Spring tension clips hold lamp and lens and allow fast snap-in, snap-out relamping. Matte black finish. NOTE: HID lampholder ship with the frame. Discard the incandescent lampholder that ships standard with the trims. 3. Horizontal Adjustment Mechanism: Die-form steel ring, matte black finish. Provides 360° horizontal stop, lockable. 4. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½” EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below inside fixture. 5. Mounting Bars: Galvanized steel, 0.048”; pre-installed telescoping bars extend to 30” long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bars systems. Self-centering feature simplified installation in 24” O.C. grid systems. Attaches to steel or wood joists without accessories 6. Socket Harness: Twist and lock base. 5kV (600V) pulse rated PPS, black T240 body socket with nickel-plated contacts. 18 AWG silicone leads with fiberglass outer sleeve
Labels U.L (Suitable for Damp Locations)
Teflon® is a registered trademark of E.I. DuPont. US Patent No. 5,957,573. Other US and Foreign Patents Pending.


Page of 2 4 1/2" Aperture (1) 20W CMH MR16
C4MRDCCLW, 20W G.E. HID SPOT, 12° GX10 BASE
ZONAL LUMENS AND PERCENTAGES
COEFFICIENTS OF UTILIZATION
Angle Mean CP Lumens
ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
0 6795 5 5107 457 10 2136 15 803 293 20 386 25 207 108 30 134 35 52 42 40 30 45 16 12 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
0-30 857 85.75 94.06 0-40 899 89.97 98.69 0-60 911 91.16 100.00 0-90 911 91.16 100.00 40-90 11 1.19 1.31 60-90 0 .00 .00 90-180 0 .00 .00 0-180 911 91.16 100.00
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.09 1.06 1.01 1.01 1.01 .97 .97 .97 .93 .93 .93 .91 1 1.06 1.04 1.03 1.02 1.04 1.03 1.01 1.00 .99 .98 .97 .95 .95 .94 .92 .92 .91 .90 2 1.03 1.01 .98 .96 1.01 .99 .97 .95 .96 .95 .93 .94 .93 .92 .91 .91 .90 .88 3 1.01 .97 .95 .93 .99 .96 .94 .92 .94 .92 .91 .92 .91 .90 .91 .89 .88 .87 4 .99 .95 .92 .90 .98 .94 .92 .90 .92 .90 .89 .91 .89 .88 .89 .88 .87 .86 5 .97 .93 .90 .88 .95 .92 .89 .87 .90 .88 .87 .89 .87 .86 .88 .87 .85 .84 6 .95 .91 .88 .86 .94 .90 .87 .85 .89 .87 .85 .88 .86 .84 .87 .85 .84 .83 7 .93 .89 .86 .84 .92 .88 .86 .83 .87 .85 .83 .86 .84 .83 .86 .84 .82 .82 8 .92 .87 .84 .82 .91 .86 .84 .82 .86 .83 .82 .85 .83 .81 .84 .83 .81 .80 9 .90 .85 .83 .81 .89 .85 .83 .81 .84 .82 .80 .84 .82 .80 .83 .81 .80 .79 10 .88 .84 .81 .79 .88 .84 .81 .79 .83 .81 .79 .82 .80 .79 .82 .80 .79 .78
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 2475 55 0 65 0 75 0 85 0
CU VALUE GREATER THAN 1.00 determined in accordance with current IES published procedures
LUMEN RATING = 1000 LMS. SC = .3 TEST REPORT NO. 3405FR
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
COEFFICIENTS OF UTILIZATION
Angle Mean CP Lumens
ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
0 3280 5 2896 267 10 2105 15 1316 386 20 715 25 342 184 30 187 35 92 67 40 53 45 30 22 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
** EFFICIENCY = 92.5% **
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 4709 55 0 65 0 75 0 85 0
CU VALUE GREATER THAN 1.00 determined in accordance with current IES published procedures
LUMEN RATING = 1000 LMS. SC = .4 TEST REPORT NO. 3392FR
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
ZONAL LUMENS AND PERCENTAGES
COEFFICIENTS OF UTILIZATION
Angle Mean CP Lumens
ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
0 2247 5 1983 187 10 1629 15 1300 366 20 934 25 504 255 30 261 35 120 88 40 62 45 37 27 50 5 55 1 2 60 1 65 1 1 70 0 75 0 0 80 0 85 0 0 90 0
0-30 807 80.79 87.15 0-40 896 89.63 96.69 0-60 925 92.56 99.85 0-90 926 92.70 100.00 40-90 30 3.07 3.31 60-90 1 .14 .15 90-180 0 .00 .00 0-180 926 92.70 100.00
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.10 1.08 1.03 1.03 1.03 .99 .99 .99 .95 .95 .95 .93 1 1.07 1.05 1.03 1.02 1.05 1.03 1.02 1.00 .99 .98 .97 .96 .95 .94 .93 .92 .92 .90 2 1.03 1.00 .98 .95 1.02 .99 .96 .94 .96 .94 .92 .93 .92 .91 .91 .90 .89 .87 3 1.00 .96 .93 .91 .99 .95 .92 .90 .93 .91 .89 .91 .89 .87 .89 .88 .86 .85 4 .97 .93 .89 .87 .96 .92 .89 .86 .90 .87 .85 .88 .86 .84 .87 .85 .83 .82 5 .94 .89 .85 .83 .93 .88 .85 .82 .87 .84 .82 .86 .83 .81 .84 .82 .80 .79 6 .92 .86 .83 .80 .91 .86 .82 .80 .85 .82 .79 .83 .81 .79 .82 .80 .78 .77 7 .89 .83 .79 .77 .88 .83 .79 .76 .82 .78 .76 .81 .78 .76 .80 .77 .75 .75 8 .87 .80 .77 .74 .86 .80 .76 .74 .79 .76 .74 .78 .75 .73 .77 .75 .73 .72 9 .84 .78 .74 .71 .83 .77 .74 .71 .76 .73 .71 .76 .73 .71 .75 .72 .70 .70 10 .81 .75 .72 .69 .81 .75 .72 .69 .74 .71 .69 .74 .71 .68 .73 .70 .68 .67
LUMINANCE SUMMARY
ANGLE MEAN CD/SQ M
45 5737 55 260 65 211 75 157 85 200
CU VALUE GREATER THAN 1.00 determined in accordance with current IES published procedures
LUMEN RATING = 1000 LMS. SC = .6 TEST REPORT NO. 3391FR