Page 1 of 2 4 1/2” Aperture PAR30 Reflector Trim

1-1/4" Max. Ceiling Thk.
* 7-3/4" min. is for up to 3/4" thick ceiling
5-3/4" Dia. 4-1/2" Dia. C4P30DCCDW / C4120 or C4P30DCCDW / C4A120
Ceiling Cutout: 5 1/16" (129 mm) Dia.

Labels UL Listed (suitable for damp locations).
1. Trim: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image. Removable from below for bottom relamping. Available with painted white or polished flange. 2. Reflector Housing: Snaps into frame for easy tool-less installation. Provides friction spring clips to secure aperture cone. Interchangeable with other Evolution 4" line voltage trims. 3. Socket Harness: Bracket mounted to reflector housing insuring correct optical alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed plug-in quick connector for power connec- tion to junction box. 4. Frame-In Kit: Compatible Frame-In Kits are listed above. Non-IC and Non-IC AirSeal® - Thermal insulation shall not be installed above a recessed luminaire (fixture) or within 3 in. (75 mm) of the recessed lumi- naire’s (fixture’s) enclosure or wiring compartment. IC-AirSeal® - Fixture may be in direct contact with insulation.
Alzak® is a registered trademark of ALCOA. US and Foreign Patents Pending.

Champaign Bronze CCZ Specular Clear CL Specular Gold GD Specular Black BK Pewter CPW White WH
1Specify desired flange W White, P Polished

Page 2 of 2 4 1/2” Aperture PAR30 Reflector Trim
CERTIFIED TEST REPORT NO. 2001FR COMPUTED BY LSI PROGRAM **TEST-LITE** CALCULITE 4 1/2" DIA. APERTURE OPEN DOWNLIGHT CAT. # C4P30DCLP, SPECULAR CLEAR FINISH REFLECTOR 75W PAR30 FLOOD GE LAMP. LUMEN RATING = 1030 LMS.

Candlepower Summary Angle Mean CP Lumens 0 3308 5 3035 278 10 2259 15 1159 361 20 514 25 224 122 30 91 35 36 28 40 16 45 4 5 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 760 73.82 95.86 0-40 788 76.54 99.39 0-60 793 77.01 100.00 0-90 793 77.01 100.00 40-90 4 .47 .61 60-90 0 .00 .00 90-180 0 .00 .00 0-180 793 77.01 100.00
** Efficiency = 77.0% **
Tested According To IES Procedures. Test Distance Exceeds Five
Times The Greatest Luminous Opening Of Luminaire.
Coefficients of Utilization % Effective Ceiling Cavity Reflectance 80 70 50 30 10 0 % Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77 1 .88 .87 .86 .87 .85 .84 .83 .82 .82 .80 .80 .79 .78 .77 .77 .76 2 .85 .83 .81 .83 .82 .80 .81 .80 .79 .79 .78 .77 .77 .76 .75 .74 3 .82 .80 .78 .81 .79 .78 .79 .78 .77 .78 .77 .75 .76 .75 .74 .73 4 .80 .78 .76 .79 .77 .75 .78 .76 .74 .76 .75 .74 .75 .74 .73 .72 5 .78 .75 .73 .77 .75 .73 .76 .74 .72 .75 .73 .72 .74 .72 .71 .71 6 .76 .73 .72 .76 .73 .71 .75 .73 .71 .74 .72 .71 .73 .71 .70 .70 7 .74 .72 .70 .74 .72 .70 .73 .71 .69 .72 .70 .69 .72 .70 .69 .68 8 .72 .70 .68 .72 .70 .68 .71 .69 .68 .71 .69 .68 .70 .69 .67 .67 9 .71 .69 .67 .71 .69 .67 .70 .68 .67 .70 .68 .66 .69 .67 .66 .66 10 .70 .67 .65 .69 .67 .65 .69 .67 .65 .68 .66 .65 .68 .66 .65. .64 20% Floor Cavity Reflectance
Room Cavity Ratio