Page 1 of 1 4½" X 4½" Square Aperture (1) MR16 Low Voltage

Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.

Features 1. Reflector Trim: 55° physical and reflected cutoff. Available with integral flange painted white or polished to match inside of cone. 2. Lamp Holder: Unitized optics ensure alignment of lamp and aperture cone. Soft diffusion lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Ceramic body with mica cover, GX5.3 (MR-16) base. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 9. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 10. Transformer: Replaceable from below. Magnetic: 120/277V 60 Hz. Dual- voltage, core & coil. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.
Options and Accessories Accepts two optical accessories 2" diameter color filters/specialty filters: ADF2/AF2 2" diameter louver: AL2HC


Page 2 of 2 4½" X 4½" Square Aperture (1) MR16 Low Voltage
Candlepower Summary Angle Mean CP Lumens 0 1371 5 1326 123 10 1137 15 863 243 20 567 25 324 162 30 184 35 108 70 40 48 45 20 19 50 7 55 1 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens %Lamp %Luminaire 0-30 528 66.02 85.13 0-40 598 74.82 96.48 0-60 619 77.42 99.83 0-90 620 77.56 100.00 40-90 21 2.73 3.52 60-90 1 .1 .17 90-180 0 .00 .00 0-180 620 77.56 100.00 Efficiency = 77.6%
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR 0 .92 .90 .86 .86 .86 .83 .83 .83 .79 .79 .79 .78
1 .89 .88 .87 .85 .88 .86 .85 .84 .83 .82 .81 .80 .80 .79 .78 .77 .77 .75
2 .86 .84 .82 .80 .85 .83 .81 .79 .80 .79 .77 .78 .77 .76 .76 .75 .74 .73
3 .84 .80 .78 .76 .82 .79 .77 .75 .78 .76 .74 .76 .74 .73 .74 .73 .72 .71
4 .81 .77 .74 .72 .80 .77 .74 .72 .75 .73 .71 .74 .72 .70 .72 .71 .69 .68
5 .79 .74 .71 .69 .78 .74 .71 .69 .72 .70 .68 .71 .69 .67 .70 .68 .67 .66
6 .77 .72 .69 .66 .76 .71 .68 .66 .70 .68 .66 .69 .67 .65 .68 .66 .65 .64
Luminance Summary - CD. / SQ. M. Angle Mean CD/SQ M 45 2164 55 172 65 53 75 87 85 391
7 .74 .69 .66 .64 .73 .69 .66 .63 .68 .65 .63 .67 .65 .63 .66 .64 .62 .62
8 .72 .67 .63 .61 .71 .66 .63 .61 .65 .63 .61 .65 .62 .61 .64 .62 .60 .60
9 .69 .64 .61 .59 .69 .64 .61 .59 .63 .60 .59 .63 .60 .58 .62 .60 .58 .57
10 .67 .62 .59 .57 .67 .62 .59 .57 .61 .58 .57 .61 .58 .56 .60 .58 .56 .56
Lumen Rating = 800 LMS. SC = .6 Test Report No. 3366FR
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 53.0
Tested According To Ies Procedures. Test Distance Exceeds Five
Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 35 3.38 5' 24 2.34 6' 16 1.49 24' x 24' x 12' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances
Times The Greatest Luminous Opening Of Luminaire
Candlepower Summary Angle Mean CP Lumens 0 684 5 692 65 10 665 15 630 175 20 549 25 411 188 30 256 35 139 93 40 56 45 21 20 50 6 55 1 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 428 52.00 78.82 0-40 521 63.22 95.83 0-60 543 65.90 99.88 0-90 544 65.97 100.00 40-90 22 2.75 4.17 60-90 0 .08 .12 90-180 0 .00 .00 0-180 544 65.97 100.00 Efficiency = 66.0%
Zonal Cavity Method Effective Floor Cavity Reflectance = .20
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR 0 .79 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66
1 .76 .74 .73 .72 .74 .73 .72 .71 .70 .70 .69 .68 .67 .67 .66 .65 .65 .64
2 .73 .71 .69 .67 .72 .70 .68 .66 .67 .66 .65 .66 .65 .63 .64 .63 .62 .61
3 .70 .67 .65 .63 .69 .66 .64 .62 .65 .63 .61 .63 .62 .60 .62 .61 .60 .59
4 .68 .64 .62 .59 .67 .64 .61 .59 .62 .60 .58 .61 .59 .58 .60 .58 .57 .56
5 .65 .61 .58 .56 .64 .61 .58 .56 .60 .57 .55 .59 .56 .55 .58 .56 .54 .54
6 .63 .59 .56 .54 .62 .58 .55 .53 .57 .55 .53 .57 .54 .53 .56 .54 .52 .52
7 .61 .56 .53 .51 .60 .56 .53 .51 .55 .52 .50 .54 .52 .50 .53 .51 .50 .49
Luminance Summary - CD. / SQ. M. Angle Mean CD/SQ M 45 2262 55 132 65 41 75 53 85 178
8 .59 .53 .50 .48 .58 .53 .50 .48 .52 .50 .48 .52 .50 .48 .51 .49 .48 .47
9 .56 .51 .48 .46 .56 .51 .48 .46 .50 .47 .46 .50 .47 .45 .49 .47 .45 .45
10 .54 .49 .46 .44 .53 .49 .46 .44 .48 .45 .44 .48 .45 .43 .47 .45 .43 .43
Lumen Rating = 825 LMS. SC = .8 Test Report No. 3367FR
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 54.0
Tested According To Ies Procedures. Test Distance Exceeds Five
Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 31 3.38 5' 21 2.34 6' 14 1.49 24' x 24' x 12' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances
Times The Greatest Luminous Opening Of Luminaire

Page 1 of 1 4½" X 4½" Square Aperture (1) 20W CMH MR16
9.66"
8.16"
2" Max. Ceiling Thickness 5.75" 4.5"
9.66"
Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.
Features 1. Reflector Trim: 55° physical and reflected cutoff. Available with integral flange painted white or polished to match inside of cone. 2. Lamp Holder/Trim Adjustment Assembly: Unitized optics ensure alignment of lamp and aperture cone regardless of ceiling thickness. Soft diffusion lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Twist and lock base. 5kV (600V) pulse rated PPS, black T240 body socket with nickel-plated contacts. 18 AWG silicone leads with fiberglass outer sleeve. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Ballast/Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement. 9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 10. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 11. Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor >0.99, THD
Ballast ANSI Code Voltage Max. Amps Input Watts 20W MH M156 120/277V 0.20/0.09 22
Options and Accessories Accepts one optical accessory 2" diameter color filter/specialty filter: ADF2/AF2 2" diameter louver: AL2HC
Cat. No.:
Lamp(s):
Notes:

Page 2 of 2 4½" X 4½" Square Aperture (1) 20W CMH MR16
Candlepower Summary Angle Mean CP Lumens 0 2816 5 2763 251 10 2198 15 1250 376 20 604 25 328 172 30 223 35 156 98 40 91 45 61 48 50 36 55 9 12 60 1 65 0 0 70 0 75 0 0 80 1 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 798 79.88 83.37 0-40 897 89.71 93.63 0-60 957 95.75 99.93 0-90 958 95.82 100.00 40-90 61 6.10 6.37 60-90 0 .07 .07 90-180 0 .00 .00 0-180 958 95.82 100.00 Efficiency = 95.8%
Zonal Cavity Method Effective Floor Cavity Reflectance = .20
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR 0 1.14 1.11 1.06 1.06 1.06 1.02 1.02 1.02 .98 .98 .98 .96
1 1.10 1.08 1.07 1.05 1.08 1.07 1.05 1.03 1.03 1.01 1.00 .99 .98 .97 .96 .95 .95 .93
2 1.07 1.04 1.01 .98 1.05 1.02 .99 .97 .99 .97 .95 .96 .95 .93 .94 .93 .91 .90
3 1.03 .99 .96 .93 1.02 .98 .95 .93 .96 .93 .91 .94 .92 .90 .92 .90 .89 .87
4 1.00 .96 .92 .89 .99 .95 .91 .88 .93 .90 .88 .91 .88 .87 .89 .87 .86 .85
5 .97 .92 .88 .85 .96 .91 .87 .85 .89 .86 .84 .88 .85 .83 .87 .85 .83 .82
6 .95 .89 .85 .82 .93 .88 .84 .82 .87 .84 .81 .86 .83 .81 .85 .82 .80 .79
Luminance Summary - CD. / SQ. M. Angle Mean Cd/sq M 45 9463 55 1706 65 30 75 0 85 147
7 .92 .86 .82 .79 .91 .85 .81 .78 .84 .81 .78 .83 .80 .78 .82 .79 .77 .77
8 .89 .83 .79 .76 .88 .82 .78 .76 .81 .78 .76 .80 .77 .75 .80 .77 .75 .74
9 .86 .80 .76 .73 .86 .79 .76 .73 .79 .75 .73 .78 .75 .73 .77 .75 .73 .72
10 .84 .77 .74 .71 .83 .77 .74 .71 .76 .73 .71 .76 .73 .70 .75 .72 .70 .69
CU Value Greater Than 1.00
Lumen Rating = 1000 LMS. SC = .5 Test Report No. 3415FR
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 26.0
Tested According To IES Procedures. Test Distance Exceeds Five
Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 54 1.63 5' 38 1.13 6' 24 0.72 75' x 75' x 10' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances
Times The Greatest Luminous Opening Of Luminaire
Candlepower Summary Angle Mean CP Lumens 0 1601 5 1636 153 10 1545 15 1290 354 20 873 25 515 255 30 299 35 184 121 40 103 45 62 51 50 35 55 9 12 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 762 76.22 80.54 0-40 883 88.30 93.30 0-60 946 94.61 99.96 0-90 946 94.64 100.00 40-90 63 6.34 6.70 60-90 0 .04 .04 90-180 0 .00 .00 0-180 946 94.64 100.00 Efficiency = 94.6%
Zonal Cavity Method Effective Floor Cavity Reflectance = .20
CC 80 70 50 30 10
WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR 0 1.13 1.10 1.05 1.05 1.05 1.01 1.01 1.01 .97 .97 .97 .95
1 1.09 1.07 1.05 1.03 1.07 1.05 1.03 1.02 1.01 1.00 .99 .97 .97 .96 .94 .94 .93 .91
2 1.05 1.02 .99 .96 1.03 1.00 .97 .95 .97 .95 .93 .94 .93 .91 .92 .91 .89 .88
3 1.01 .97 .93 .91 1.00 .96 .93 .90 .93 .91 .89 .91 .89 .87 .89 .88 .86 .85
4 .98 .93 .89 .86 .97 .92 .89 .85 .90 .87 .85 .88 .86 .84 .87 .84 .83 .82
5 .95 .89 .84 .82 .93 .88 .84 .81 .86 .83 .81 .85 .82 .80 .84 .81 .79 .78
6 .92 .85 .81 .78 .90 .85 .81 .78 .83 .80 .77 .82 .79 .77 .81 .78 .76 .75
7 .88 .82 .77 .75 .87 .81 .77 .74 .80 .76 .74 .79 .76 .73 .78 .75 .73 .72
Luminance Summary - CD. / SQ. M. Angle Mean Cd/sq M 45 9688 55 1698 65 41 75 0 85 0
8 .85 .78 .74 .71 .84 .78 .74 .71 .77 .73 .71 .76 .73 .70 .75 .72 .70 .69
9 .82 .75 .71 .68 .81 .75 .71 .68 .74 .70 .68 .73 .70 .67 .72 .69 .67 .66
10 .79 .72 .68 .65 .78 .72 .68 .65 .71 .67 .65 .71 .67 .65 .70 .67 .65 .64
CU Value Greater Than 1.00
Lumen Rating = 1000 LMS. SC = .7 Test Report No. 3414FR
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 26.0
Tested According To IES Procedures. Test Distance Exceeds Five
Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 53 1.63 5' 37 1.13 6' 24 0.72 75' x 75' x 10' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances
Times The Greatest Luminous Opening Of Luminaire