Calculite ® Matrix Low Voltage Open Downlight C4X4MRD

Page 1 of 1 4½" X 4½" Square Aperture (1) MR16 Low Voltage

5 6 9 8 7 1 2 3 10 4

Lightolier C4X4MRD — 5 6 9 8 7 1 2 3 10 4 diagram (page 1)
図 1

Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.

Ordering Information

Lightolier C4X4MRD — Ordering Information diagram (page 1)
図 2 · Ordering Information
Frame-In KitsReflector Trims Finish/FlangeLamp C4 X4LVMU Magnetic 120/277V C4X4LVE1 Electronic 120V C4X4LVE2 Electronic 277VC4X4MRDCLW S C4X4MRDCLP S C4X4MRDCCLW C C4X4MRDCCLP C C4X4MRDCCDW C C4X4MRDCCDP C C4X4MRDWHW Wpecular Clear/White pecular Clear/Polished omfort Clear/White omfort Clear/Polished omfort Clear Diffuse/White omfort Clear Diffuse/Polished hite/White(1) 12V MR16 Type Lamp 65W Max or IR 37W Max

Features 1. Reflector Trim: 55° physical and reflected cutoff. Available with integral flange painted white or polished to match inside of cone. 2. Lamp Holder: Unitized optics ensure alignment of lamp and aperture cone. Soft diffusion lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Ceramic body with mica cover, GX5.3 (MR-16) base. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 9. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 10. Transformer: Replaceable from below. Magnetic: 120/277V 60 Hz. Dual- voltage, core & coil. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.

Options and Accessories Accepts two optical accessories 2" diameter color filters/specialty filters: ADF2/AF2 2" diameter louver: AL2HC

Labels UL, cUL (Suitable for Damp Locations)

Lightolier C4X4MRD — Labels UL, cUL (Suitable for Damp Locations) diagram (page 1)
図 3 · Labels UL, cUL (Suitable for Damp Locations)
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0507
Page 2 of the Lightolier C4X4MRD user manual — 50W MR16 SYLVANIA 60° VWFL
2ページ · クリックして拡大
2ページ

Calculite ® Matrix Low Voltage Open Downlight C4X4MRD

Page 2 of 2 4½" X 4½" Square Aperture (1) MR16 Low Voltage

4 ½" x 4 ½" Aperture 50W MR16 -40°

Candlepower Summary Angle Mean CP Lumens 0 1371 5 1326 123 10 1137 15 863 243 20 567 25 324 162 30 184 35 108 70 40 48 45 20 19 50 7 55 1 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

Zonal Lumens And Percentages Zone Lumens %Lamp %Luminaire 0-30 528 66.02 85.13 0-40 598 74.82 96.48 0-60 619 77.42 99.83 0-90 620 77.56 100.00 40-90 21 2.73 3.52 60-90 1 .1 .17 90-180 0 .00 .00 0-180 620 77.56 100.00 Efficiency = 77.6%

Coefficients Of Utilization Zonal Cavity Method Effective Floor Cavity Reflectance = .20

CC 80 70 50 30 10

WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR 0 .92 .90 .86 .86 .86 .83 .83 .83 .79 .79 .79 .78

1 .89 .88 .87 .85 .88 .86 .85 .84 .83 .82 .81 .80 .80 .79 .78 .77 .77 .75

2 .86 .84 .82 .80 .85 .83 .81 .79 .80 .79 .77 .78 .77 .76 .76 .75 .74 .73

3 .84 .80 .78 .76 .82 .79 .77 .75 .78 .76 .74 .76 .74 .73 .74 .73 .72 .71

4 .81 .77 .74 .72 .80 .77 .74 .72 .75 .73 .71 .74 .72 .70 .72 .71 .69 .68

5 .79 .74 .71 .69 .78 .74 .71 .69 .72 .70 .68 .71 .69 .67 .70 .68 .67 .66

6 .77 .72 .69 .66 .76 .71 .68 .66 .70 .68 .66 .69 .67 .65 .68 .66 .65 .64

Luminance Summary - CD. / SQ. M. Angle Mean CD/SQ M 45 2164 55 172 65 53 75 87 85 391

7 .74 .69 .66 .64 .73 .69 .66 .63 .68 .65 .63 .67 .65 .63 .66 .64 .62 .62

8 .72 .67 .63 .61 .71 .66 .63 .61 .65 .63 .61 .65 .62 .61 .64 .62 .60 .60

50W MR16 G.E. 40° FL

9 .69 .64 .61 .59 .69 .64 .61 .59 .63 .60 .59 .63 .60 .58 .62 .60 .58 .57

10 .67 .62 .59 .57 .67 .62 .59 .57 .61 .58 .57 .61 .58 .56 .60 .58 .56 .56

Lumen Rating = 800 LMS. SC = .6 Test Report No. 3366FR

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 53.0

Tested According To Ies Procedures. Test Distance Exceeds Five

Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 35 3.38 5' 24 2.34 6' 16 1.49 24' x 24' x 12' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances

Times The Greatest Luminous Opening Of Luminaire

4 ½" x 4 ½" Aperture 50W MR16 -60°

Candlepower Summary Angle Mean CP Lumens 0 684 5 692 65 10 665 15 630 175 20 549 25 411 188 30 256 35 139 93 40 56 45 21 20 50 6 55 1 2 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 428 52.00 78.82 0-40 521 63.22 95.83 0-60 543 65.90 99.88 0-90 544 65.97 100.00 40-90 22 2.75 4.17 60-90 0 .08 .12 90-180 0 .00 .00 0-180 544 65.97 100.00 Efficiency = 66.0%

Coefficients Of Utilization

Zonal Cavity Method Effective Floor Cavity Reflectance = .20

CC 80 70 50 30 10

WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR 0 .79 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66

1 .76 .74 .73 .72 .74 .73 .72 .71 .70 .70 .69 .68 .67 .67 .66 .65 .65 .64

2 .73 .71 .69 .67 .72 .70 .68 .66 .67 .66 .65 .66 .65 .63 .64 .63 .62 .61

3 .70 .67 .65 .63 .69 .66 .64 .62 .65 .63 .61 .63 .62 .60 .62 .61 .60 .59

4 .68 .64 .62 .59 .67 .64 .61 .59 .62 .60 .58 .61 .59 .58 .60 .58 .57 .56

5 .65 .61 .58 .56 .64 .61 .58 .56 .60 .57 .55 .59 .56 .55 .58 .56 .54 .54

6 .63 .59 .56 .54 .62 .58 .55 .53 .57 .55 .53 .57 .54 .53 .56 .54 .52 .52

7 .61 .56 .53 .51 .60 .56 .53 .51 .55 .52 .50 .54 .52 .50 .53 .51 .50 .49

Luminance Summary - CD. / SQ. M. Angle Mean CD/SQ M 45 2262 55 132 65 41 75 53 85 178

8 .59 .53 .50 .48 .58 .53 .50 .48 .52 .50 .48 .52 .50 .48 .51 .49 .48 .47

50W MR16 SYLVANIA 60° VWFL

9 .56 .51 .48 .46 .56 .51 .48 .46 .50 .47 .46 .50 .47 .45 .49 .47 .45 .45

10 .54 .49 .46 .44 .53 .49 .46 .44 .48 .45 .44 .48 .45 .43 .47 .45 .43 .43

Lumen Rating = 825 LMS. SC = .8 Test Report No. 3367FR

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 54.0

Tested According To Ies Procedures. Test Distance Exceeds Five

Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 31 3.38 5' 21 2.34 6' 14 1.49 24' x 24' x 12' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances

Times The Greatest Luminous Opening Of Luminaire

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0507
Show 4 more labels / short text on this page
60° · 1500 30° · 60° · 30°
Page 3 of the Lightolier C4X4MRD user manual — Job Name:
3ページ · クリックして拡大
3ページ

Calculite ® Matrix HID Open Downlight C4X4MRD

Page 1 of 1 4½" X 4½" Square Aperture (1) 20W CMH MR16

8"

9.66"

8.16"

2" Max. Ceiling Thickness 5.75" 4.5"

9.66"

Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.

Ordering Information

Frame-In KitsReflector Trims Finish/FlangeLamp C4X420MREU Electronic 120/277VC4X4MRDCLW S C4X4MRDCLP S C4X4MRDCCLW C C4X4MRDCCLP C C4X4MRDCCDW C C4X4MRDCCDP C C4X4MRDWHW Wpecular Clear/White pecular Clear/Polished omfort Clear/White omfort Clear/Polished omfort Clear Diffuse/White omfort Clear Diffuse/Polished hite/White(1) 20W MR16 CMH GXIC Base

Features 1. Reflector Trim: 55° physical and reflected cutoff. Available with integral flange painted white or polished to match inside of cone. 2. Lamp Holder/Trim Adjustment Assembly: Unitized optics ensure alignment of lamp and aperture cone regardless of ceiling thickness. Soft diffusion lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Twist and lock base. 5kV (600V) pulse rated PPS, black T240 body socket with nickel-plated contacts. 18 AWG silicone leads with fiberglass outer sleeve. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Ballast/Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement. 9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 10. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 11. Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor >0.99, THD

Features (continued)

Ballast ANSI Code Voltage Max. Amps Input Watts 20W MH M156 120/277V 0.20/0.09 22

Options and Accessories Accepts one optical accessory 2" diameter color filter/specialty filter: ADF2/AF2 2" diameter louver: AL2HC

Labels UL, cUL (Suitable For Damp Locations)

Job Name:

Cat. No.:

Lamp(s):

Notes:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0607
Page 4 of the Lightolier C4X4MRD user manual — 20W G.E.HID MR16 40° WFL, GX10 BASE
4ページ · クリックして拡大
4ページ

Calculite ® Matrix HID Open Downlight C4X4MRD

Page 2 of 2 4½" X 4½" Square Aperture (1) 20W CMH MR16

4 ½" x 4 ½" Aperture 20W CMH MR16-25°

Candlepower Summary Angle Mean CP Lumens 0 2816 5 2763 251 10 2198 15 1250 376 20 604 25 328 172 30 223 35 156 98 40 91 45 61 48 50 36 55 9 12 60 1 65 0 0 70 0 75 0 0 80 1 85 0 0 90 0

Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 798 79.88 83.37 0-40 897 89.71 93.63 0-60 957 95.75 99.93 0-90 958 95.82 100.00 40-90 61 6.10 6.37 60-90 0 .07 .07 90-180 0 .00 .00 0-180 958 95.82 100.00 Efficiency = 95.8%

Coefficients Of Utilization

Zonal Cavity Method Effective Floor Cavity Reflectance = .20

CC 80 70 50 30 10

WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR 0 1.14 1.11 1.06 1.06 1.06 1.02 1.02 1.02 .98 .98 .98 .96

1 1.10 1.08 1.07 1.05 1.08 1.07 1.05 1.03 1.03 1.01 1.00 .99 .98 .97 .96 .95 .95 .93

2 1.07 1.04 1.01 .98 1.05 1.02 .99 .97 .99 .97 .95 .96 .95 .93 .94 .93 .91 .90

3 1.03 .99 .96 .93 1.02 .98 .95 .93 .96 .93 .91 .94 .92 .90 .92 .90 .89 .87

4 1.00 .96 .92 .89 .99 .95 .91 .88 .93 .90 .88 .91 .88 .87 .89 .87 .86 .85

5 .97 .92 .88 .85 .96 .91 .87 .85 .89 .86 .84 .88 .85 .83 .87 .85 .83 .82

6 .95 .89 .85 .82 .93 .88 .84 .82 .87 .84 .81 .86 .83 .81 .85 .82 .80 .79

Luminance Summary - CD. / SQ. M. Angle Mean Cd/sq M 45 9463 55 1706 65 30 75 0 85 147

7 .92 .86 .82 .79 .91 .85 .81 .78 .84 .81 .78 .83 .80 .78 .82 .79 .77 .77

8 .89 .83 .79 .76 .88 .82 .78 .76 .81 .78 .76 .80 .77 .75 .80 .77 .75 .74

20W G.E.HID MR16 25° FL, GX10 BASE

9 .86 .80 .76 .73 .86 .79 .76 .73 .79 .75 .73 .78 .75 .73 .77 .75 .73 .72

10 .84 .77 .74 .71 .83 .77 .74 .71 .76 .73 .71 .76 .73 .70 .75 .72 .70 .69

CU Value Greater Than 1.00

Lumen Rating = 1000 LMS. SC = .5 Test Report No. 3415FR

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 26.0

Tested According To IES Procedures. Test Distance Exceeds Five

Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 54 1.63 5' 38 1.13 6' 24 0.72 75' x 75' x 10' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances

Times The Greatest Luminous Opening Of Luminaire

4 ½" x 4 ½" Aperture 20W CMH MR16-40°

Candlepower Summary Angle Mean CP Lumens 0 1601 5 1636 153 10 1545 15 1290 354 20 873 25 515 255 30 299 35 184 121 40 103 45 62 51 50 35 55 9 12 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 762 76.22 80.54 0-40 883 88.30 93.30 0-60 946 94.61 99.96 0-90 946 94.64 100.00 40-90 63 6.34 6.70 60-90 0 .04 .04 90-180 0 .00 .00 0-180 946 94.64 100.00 Efficiency = 94.6%

Coefficients Of Utilization

Zonal Cavity Method Effective Floor Cavity Reflectance = .20

CC 80 70 50 30 10

WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR 0 1.13 1.10 1.05 1.05 1.05 1.01 1.01 1.01 .97 .97 .97 .95

1 1.09 1.07 1.05 1.03 1.07 1.05 1.03 1.02 1.01 1.00 .99 .97 .97 .96 .94 .94 .93 .91

2 1.05 1.02 .99 .96 1.03 1.00 .97 .95 .97 .95 .93 .94 .93 .91 .92 .91 .89 .88

3 1.01 .97 .93 .91 1.00 .96 .93 .90 .93 .91 .89 .91 .89 .87 .89 .88 .86 .85

4 .98 .93 .89 .86 .97 .92 .89 .85 .90 .87 .85 .88 .86 .84 .87 .84 .83 .82

5 .95 .89 .84 .82 .93 .88 .84 .81 .86 .83 .81 .85 .82 .80 .84 .81 .79 .78

6 .92 .85 .81 .78 .90 .85 .81 .78 .83 .80 .77 .82 .79 .77 .81 .78 .76 .75

7 .88 .82 .77 .75 .87 .81 .77 .74 .80 .76 .74 .79 .76 .73 .78 .75 .73 .72

Luminance Summary - CD. / SQ. M. Angle Mean Cd/sq M 45 9688 55 1698 65 41 75 0 85 0

8 .85 .78 .74 .71 .84 .78 .74 .71 .77 .73 .71 .76 .73 .70 .75 .72 .70 .69

20W G.E.HID MR16 40° WFL, GX10 BASE

9 .82 .75 .71 .68 .81 .75 .71 .68 .74 .70 .68 .73 .70 .67 .72 .69 .67 .66

10 .79 .72 .68 .65 .78 .72 .68 .65 .71 .67 .65 .71 .67 .65 .70 .67 .65 .64

CU Value Greater Than 1.00

Lumen Rating = 1000 LMS. SC = .7 Test Report No. 3414FR

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 26.0

Tested According To IES Procedures. Test Distance Exceeds Five

Multiple Unit Data - RCR 1 Spacing Initial Watts/ On Center Footcandles Sq Ft 4' 53 1.63 5' 37 1.13 6' 24 0.72 75' x 75' x 10' Room, Workplane 2 1/2' above floor, 80/50/20% Reclectances

Times The Greatest Luminous Opening Of Luminaire

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0607
Show 4 more labels / short text on this page
60° · 3000 30° · 60° · 1500 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C4X4MRDについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C4X4MRDに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C4X4MRD 取扱説明書(PDF)

4 ページ·394 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…