Page of 2 6" Aperture A19 / A21 / BT15 / MB19 Reflector Trim
IC AirSeal® C6AIC / (C6DAIC) Non-IC AirSeal® C6A120 / (C6DA120) Non-IC C6120 / (C6D120)
20 1/4" O.A. Included) (Mounting Bars Adjustment Included) (Mounting Bars Adjustment 13 3/4" TO 24"
6" Dia. 7 1/4" Dia. *8 3/4"min. is for up to 3/4" thick ceiling. 1/2" to 1 1/4" Max. Ceiling Thk.
**11 1/8"min. is for up to 3/4" thick ceiling. C6ADCLW / C6D120 or C6ADCLW / C6DA120 C6ADCLW / C6120 or C6ADCLW / C6A120
Ceiling Cutout: 6 11/16" Dia.

Features 1. Reflector: 16 ga. aluminum, 50° visual cut-off to lamp and lamp image, medium spread distribution. Available with painted white or polished flange. Interchangeable with other Evolution 6” line voltage trims. 2. Socket Harness: Spring tension clips snap into die-cast aluminum top at pre-focused positions insuring correct optical alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed plug-in quick connector for power connection to junction box. 3. Frame-in-Kit: Compatible frame-in kits are listed above. See separate frame-in kit specification sheets for details. Non-IC and Non-IC AirSeal® - Insulation must be kept 3” away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. IC-AirSeal® - Fixture may be in direct contact with insulation.
Labels UL Listed (suitable for damp locations), I.B.E.W.
US Patent No. 5,957,573. Other US and Foreign Patents Pending.


Page of 2 6" Aperture A19 / A21 / BT15 / MB19 Reflector Trim
SPACING RATIO = 0.9
CERTIFIED TEST REPORT NO. 0833FR COMPUTED BY LSI PROGRAM **TEST-LITE**
CERTIFIED TEST REPORT NO. 0835FR COMPUTED BY LSI PROGRAM **TEST-LITE** CALCULITE 6” DIA/ APERTURE BY-LAMP OPEN DOWNLIGHT CAT. #C6AIC120/C6ADCLW, SPECULAR CLEAR FINISH REFLECTOR 100W BT15 PHILLIPS LAMP. LUMEN RATING = 1880 LMS. LOWER POSITION
RECESSED OPEN REFLECTOR DOWNLIGHT 6” DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR 150W A-21 SYLVANIA LAMP. LUMEN RATING = 2780 LMS.


ANGLE MEAN CP LUMENS 0 1390 5 1375 131 10 1338 15 1284 364 20 1224 25 1119 509 30 934 35 696 432 40 422 45 114 129 50 16 55 3 5 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0 ZONAL LUMENS AND PERCENTAGES
ANGLE MEAN CP LUMENS 0 1204 5 1171 111 10 1090 15 1002 283 20 897 25 771 348 30 567 35 394 250 40 239 45 85 82 50 12 55 2 4 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0 ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP % LUMINAIRE 0-30 1003 36.08 63.94 0-40 1434 51.60 91.46 0-60 1568 56.42 99.99 0-90 1568 56.42 100.00 40-90 134 4.82 8.54 60-90 0 .01 .01 90-180 0 .00 .00 0-180 1568 56.42 100.00
ZONE LUMENS % LAMP % LUMINAIRE 0-30 741 39.42 68.82 0-40 991 52.75 92.08 0-60 1076 57.27 99.98 0-90 1076 5728 100.00 40-90 85 4.54 7.92 60-90 0 .01 .02 90-180 0 .00 .00 0-180 1076 57.28 100.00
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
**EFFICIENCY = 57.3% ** Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 30 10 0 % WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .63 .62 .61 .6 61 .60 .60 .59 .58 .57 .57 .56 .56 .55 .55 .54 2 .59 .57 .56 .58 .57 .55 .57 .55 .54 .55 .54 .53 .53 .53 .52 .51 3 .56 .53 .51 .55 .53 .51 .54 .52 .50 .52 .51 .49 .51 .50 .49 .48 4 .53 .50 .48 .52 .50 .48 .51 .49 .47 .50 .48 .47 .49 .47 .46 .45 5 .50 .47 .45 .49 .46 .44 .48 .46 .44 .47 .45 .44 .46 .45 .43 .42 6 .47 .44 .42 .46 .44 .42 .46 .43 .41 .45 .43 .41 .44 .42 .41 .40 7 .44 .41 .39 .44 .41 .39 .43 .40 .39 .42 .40 .38 .42 .40 .38 .37 8 .41 .38 .36 .41 .38 .36 .40 .38 .36 .40 .38 .36 .39 .37 .36 .35 9 .39 .36 .34 .39 .36 .34 .38 .35 .33 .38 .35 .33 .37 .35 .33 .32 10 .36 .33 .31 .36 .33 .31 .36 .33 .31 .35 .33 .31 .35 .33 .31 .30
COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 30 10 0 % WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .64 .63 .62 .63 .62 .61 .61 .60 .59 .59 .58 .57 .57 .56 .56 .55 2 .61 .59 .57 .60 .58 .56 .58 .56 .55 .56 .55 .54 .55 .54 .53 .52 3 .57 .55 .53 .56 .54 .53 .55 .53 .52 .54 .52 .51 .53 .51 .50 .49 4 .54 .52 .50 .54 .51 .49 .53 .50 .49 .51 .50 .48 .50 .49 .48 .47 5 .51 .48 .46 .51 .48 .46 .50 .48 .46 .49 .47 .45 .48 .46 .45 .44 6 .49 .46 .44 .48 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .43 .42 7 .46 .43 .41 .46 .43 .41 .45 .42 .41 .44 .42 .40 .44 .42 .40 .40 8 .44 .41 .39 .43 .40 .38 .43 .40 .38 .42 .40 .38 .42 .39 .38 .37 9 .41 .38 .36 .41 .38 .36 .40 .38 .36 .40 .37 .36 .39 .37 .35 .35 10 .39 .36 .34 .39 .36 .34 .38 .35 .34 .38 .35 .34 .37 .35 .33 .33
ROOM CAVITY RATIO
20% FLOOR CAVITY REFLECTANCE
20% FLOOR CAVITY REFLECTANCE
Conversion Factors 150W A21: Clear; C.U. x 1.0; Diffuse/Gold. C.U. x 0.90FL 60W - 100W A19: Clear; C.U. x 1.15; Diffuse/Gold. C.U. x 1.0FL
Conversion Factors 60W to 100W BT15: Clear C.U. x 1.00; Diffuse/Gold, C.U. x 0.90 60W to 100W MB19: Clear C.U. x 0.95; Diffuse/Gold, C.U. x 0.85