Non-IC AirSeal ® C6A120 / (C6DA120) 9 1/2" DIA. (12 1/4" DIA.)
7 3/4" (9 1/8") 12 1/2" (15 3/4") 12 3/8" O.A. (15 3/8" O.A.)
C6 Series 8" (10 3/8") C6 Series 8 3/4" min.* (11 1/8" min.)**
* 8 3/4" min. is for up to 3/4" thick ceiling. ** 11 1/8" min. is for up to 3/4" thick ceiling. 5 3/4" Dia.
1/2" to 1" Thk. Ceiling 5 3/4" Dia. 7 1/4" Dia.
Ceiling Cutout: 6 11/16" (170 mm) Dia.
C6AWCLW / C6120 or C6AWCLW / C6A120 C6AWCLW / C6D120 or C6AWCLW / C6DA120
Features 1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image. “Cut-window” in downlight reflector exposes kick reflector to provide vertical surface wall washing. Available with painted white or polished flange. Interchangeable with other Evolution 6" line voltage trims. 2. Socket Harness: Spring tension clips snap into die-cast aluminum top at pre-focused positions insuring correct optical alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads to keyed plug-in quick connector for power connection to junction box. 3. Frame-in-Kit: Compatible frame-in kits are listed above. See separate frame-in kit specification sheets for details. Non-IC and Non-IC AirSeal® - Thermal insulation shall not be installed above a recessed luminaire (fixture) or within 3 in. (75 mm) of the recessed luminaire’s (fixture’s) enclosure or wiring compartment. IC-AirSeal® - Fixture may be in direct contact with insulation.
Labels UL Listed (suitable for damp locations), I.B.E.W.
Alzak® is a registered trademark of ALCOA. US Patent No. 5,957,573. Other US and Foreign Patents Pending.

Clear CL Champagne Bronze/Black Comfort Clear Diffuse CCD (consult factory for Champagne Specular Gold GD or Black) White WH

Page of 2 6" Aperture A19/A21/BT15/MB19 Reflector Trim
Lighting Data
Example: With Clear Alzak® and 150W A-21 units, located 3’ from wall and 5’ on center, (matching downlights 5’ on center), the illumination on the wall 3’ down from the ceiling is 18 f.c. beneath and 11 f.c. between fixtures. 5’
3’ 3’
18 f.c. 11 f.c.
Footcandles on Wall From Multiple Units - Clear Alzak® with 150W A21
1 45 42 45 36 23 36 34 12 34 2 54 51 54 41 30 41 37 18 37 3 48 47 48 34 30 34 31 17 31 4 42 41 42 28 29 28 23 20 23 5 33 33 34 22 23 22 17 18 17 6 26 26 26 18 18 18 13 14 13 7 21 21 21 14 14 14 11 11 11 8 16 17 16 12 12 12 9 13 13 13 10 10 10 8 8 8
distance from ceiling, ft.
3’ 4’ 5’ 6’
1 13 12 13 11 9 11 10 6 10 10 4 10 2 25 23 25 20 16 20 19 11 19 10 8 18 3 25 23 25 20 16 20 18 11 18 17 8 17 4 22 22 22 18 16 18 16 11 16 15 8 15 5 21 21 21 16 16 16 14 12 14 13 9 13 6 19 19 19 14 15 14 12 12 12 10 9 10 7 17 16 17 13 13 13 10 11 10 9 9 9 8 14 14 14 11 11 11 9 9 9 7 8 7 9 12 13 12 10 10 10 8 8 8 7 7 7
distance from ceiling, ft.
5’ 4’ 6’ 7’
1 5 4 5 4 3 4 4 2 4 4 2 4 2 12 11 12 10 8 10 9 6 9 9 5 9 9 3 9 3 15 14 15 13 11 13 11 8 11 11 6 11 11 5 11 4 14 13 14 12 10 12 11 8 11 10 6 10 10 5 10 5 13 13 13 11 10 11 10 8 10 9 6 9 9 5 9 6 13 12 13 10 10 10 9 8 9 9 6 9 8 5 8 7 12 12 12 10 10 10 8 7 8 7 5 7 8 11 11 11 9 9 9 8 8 8 7 7 7 6 6 6 9 10 10 10 8 8 8 7 7 7 6 6 6 5 5 5
distance from ceiling, ft.
Footcandle values are averaged and rounded off and are based on a minimum of five units. For 100W A19, multiply footcandles by 0.6. For 100W BT15, multiply footcandles by
COEFFICIENTS OF UTILIZATION
% Effective Ceiling Cavity Reflectance
.52 .48 .45 .42 .38 .36 .33 .31 .28 .26
1 .62 .60 .59 .61 .59 .58 .58 .57 .56 .56 .55 .55 .54 .54 .53
2 .57 .55 .53 .56 .54 .52 .54 .53 .51 .53 .51 .50 .51 .50 .49
3 .53 .50 .48 .52 .50 .48 .51 .49 .47 .50 .48 .46 .48 .47 .46
4 .50 .47 .44 .49 .46 .44 .48 .45 .43 .47 .45 .43 .46 .44 .42
Report 0850FR Efficiency = 56.1%
5 .46 .43 .40 .46 .43 .40 .45 .42 .40 .44 .41 .40 .43 .41 .39
Downlight Spacing Ratio = 1.0
For 100W A19, multiply C.U.’s by 1.1 For 100W BT15, multiply C.U.’s by 0.85