JA
Lightolier logo
公式取扱説明書

Lightolier C6E17OVM

2 ページ·257 KB·インテリア家具・調度品·PDF·EN
Lightolier C6E17OVM
目次 7セクション Calculite ® HID Downlight C6E17OVM · Electrical (cont.) · Job Information Type: · CANDLEPOWER DISTRIBUTION · … 表示非表示
Page 1 of the Lightolier C6E17OVM user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® HID Downlight C6E17OVM

Page 1 of 2 6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Medium Beam

Ceiling Cutout6 9/16” (167 mm) Dia. Reflector Trim Frame-In Kit Lamp (Coated, Ceramic, MH)

C6E17OVM CLW Specular Clear, White Painted Flange. CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange. MG Multi-Groove, White Trim Ring

C670MHOE1 Electronic, 120V 70W E17, ED17, BD17 (Open Rated) C670MHOE2 Electronic, 277V 70W E17, ED17, BD17 (Open Rated) C610MHOE1 Electronic, 120V 100W E17, ED17, BD17 (Open Rated) C610MHOE2 Electronic, 277V 100W E17, ED17, BD17 (Open Rated) C670MHOU Magnetic, 120/277V 70W E17, ED17, BD17 (Open Rated) C610MHOU Magnetic, 120/277V 100W E17, ED17, BD17 (Open Rated)

Features 1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide beam distribution. 2. Multi-Groove Baffle: One piece seamless aluminum. Sharply detailed con- centric rings, black finish. Permanently fastened to specular clear reflector. 3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; uni- tized construction assures proper lamp alignment to optics for consistent performance. 4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 6. Retention Springs: Rust resistant springs secure reflector in place for quick, tool-less installation. 7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attach- ment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. Electrical Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.

Electrical (cont.)

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M139 120/277 0.67/0.29 78 100W MH M90/M140 120/277 0.90/0.43 110 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting tem- perature, Type 1 Outdoor rating.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 0.90/0.43 125

Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet “A/E” Emergency Lamp: Add suffix E to FIK and Reflector Trim. See Spec.Sheet “A/E” Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to FIK (F1=120V F2=277V) Chicago Plenum: Consult Factory. Labels UL (Suitable for Damp Locations), CSA, I.B.E.W. For 100W Electronic, install fixtures with minimum spacing: 2 feet from center-to-center of adjacent luminaries; 1/2 inch from top of luminaire to over- head building member; 1 foot from luminaire center to side building member.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Page 2 of the Lightolier C6E17OVM user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® HID Downlight C6E17OVM

Page 2 of 2 6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Medium Beam

70W ED17 PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

CANDLEPOWER DISTRIBUTION

ANGLE MEAN CP LUMS. 0 3361 5 3175 302 10 2929 15 2559 731 20 2269 25 1920 879 30 1491 35 1140 708 40 735 45 294 262 50 30 55 5 9 60 2 65 1 1 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 22918 55 439 65 88 75 72 85 0

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective FloorCavity Reflectance =20%

0 .60 .59 .59 .56 .56 .54 .54 .51 1 .58 .57 .56 .55 .56 .54 .54 .52 .52 .51 .48 2 .56 .54 .52 .50 .53 .50 .51 .49 .50 .48 .46 3 .53 .50 .48 .47 .50 .46 .49 .46 .47 .45 .43 4 .51 .48 .45 .44 .47 .43 .46 .43 .45 .42 .41 5 .49 .45 .42 .41 .45 .40 .44 .40 .43 .40 .39 6 .47 .43 .40 .38 .42 .38 .42 .38 .41 .37 .37 7 .44 .40 .38 .36 .40 .35 .39 .35 .39 .35 .34 8 .42 .38 .35 .33 .38 .33 .37 .33 .37 .33 .32 9 .40 .36 .33 .31 .35 .31 .35 .31 .35 .31 .30 10 .38 .34 .31 .29 .33 .29 .33 .29 .33 .29 .28

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1911 33.54 66.1 0-40 2619 45.96 90.57 0-60 2891 50.72 99.95 0-90 2892 50.74 100 40-90 272 4.78 9.43 60-90 1 0.02 0.05 90-180-180 2892 50.74 100

LUMINAIRE INPUT WATTS = 78

** EFFICIENCY = 50.7% ** CERTIFIED TEST REPORT NO. 2368FR, DATE: NOV 8, 2003 SC = .8 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W ED17 PHILIPS CMH OPEN RATED LAMP-3K LUMEN RATING = 8500 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

CANDLEPOWER DISTRIBUTION

ANGLE MEAN CP LUMS. 0 5263 5 5047 478 10 4678 15 4096 1171 20 3653 25 3113 1424 30 2428 35 1823 1140 40 1182 45 553 457 50 73 55 7 20 60 2 65 0 1 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 43001 55 641 65 37 75 0 85 0

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance =20%

0 .66 .64 .64 .61 .61 .59 .59 .55 1 .63 .62 .60 .59 .61 .58 .58 .57 .56 .55 .52 2 .60 .58 .56 .55 .57 .54 .55 .53 .54 .52 .50 3 .58 .55 .52 .50 .54 .50 .53 .49 .51 .49 .47 4 .55 .52 .49 .47 .51 .47 .50 .46 .49 .46 .45 5 .53 .49 .46 .44 .48 .44 .47 .43 .46 .43 .42 6 .51 .46 .43 .41 .46 .41 .45 .41 .44 .41 .40 7 .48 .44 .41 .39 .43 .38 .42 .38 .42 .38 .37 8 .46 .41 .38 .36 .41 .36 .40 .36 .40 .36 .35 9 .43 .39 .36 .33 .38 .33 .38 .33 .37 .33 .32 10 .41 .36 .33 .31 .36 .31 .36 .31 .35 .31 .30

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3073 36.16 65.52 0-40 4212 49.56 89.81 0-60 4689 55.17 99.99 0-90 4690 55.18 100 40-90 477 5.62 10.19 60-90 0 0.01 0.01 90-180-180 4690 55.18 100

LUMINAIRE INPUT WATTS = 110

** EFFICIENCY = 55.2% ** CERTIFIED TEST REPORT NO. 2261FR, DATE: JUN 17, 2003 SC = .8 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 10 more labels / short text on this page
60° · 1,750 · 2,625 · 3,500 30° · 1,250 · 60° · 2,500 · 3,750 · 5,000 · 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C6E17OVMについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C6E17OVMに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C6E17OVM 取扱説明書(PDF)

2 ページ·257 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…