Page 1 of the Lightolier C6P38MH user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® HID Downlight C6P38MH

Page 1 of 2 6" Aperture, PAR38 Ceramic MH

20" (508 mm) to 30" (762 mm)

4 7 3 8 10 5 6 9 2 9 1

Top View (Magnetic Ballast)

20" (508 mm) to 30" (762 mm)

Vertical Adjustment5/8" (16 mm) to 2 7/8" (73 mm)

11" (280 mm) (100W)

Top View (Electronic Ballast)

5 7/8" (149 mm) Dia.

2" (50 mm) max. Ceiling Thickness

5 5/8" (143 mm) Dia.

7-1/4" (184 mm) Dia.

Ceiling Cutout: 6 9/16”(167 mm) Dia.

Reflector Trim Frame-In Kit Lamp

C6P38MH CLW Specular Clear, White Painted Flange. CLP Specular Clear, Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange. MG Black Multi-Groove, White Molded Trim Ring.

C670MHE1 Electronic 120V 70W PAR38 Ceramic Metal Halide C670MHE2 Electronic 277V 70W PAR38 Ceramic Metal Halide C610MHE1 Electronic 120V 100W PAR38 Ceramic Metal Halide C610MHE2 Electronic 277V 100W PAR38 Ceramic Metal Halide C670MHU Magnetic 120V/277V 70W PAR38 Ceramic Metal Halide C610MHU Magnetic 120V/277V 100W PAR38 Ceramic Metal Halide

Features 1. Reflector Trim: Clear anodized aluminum, 0.040” (16-ga.). Provides 45° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 2. Mulit-Groove Baffle: One piece seamless aluminum. Sharply detailed con- centric rings, black finish. Permanently fastened to specular clear reflector. 3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance. 4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 6. Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation. 7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 0.67/0.28 78 100W MH M90/M140 120/277 0.90/0.43 110 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125

Options and Accessories Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory. Labels UL (Suitable for Damp Locations), CSA, I.B.E.W.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • AO5O4
Show 8 more labels / short text on this page
7-1/4" (184 mm) · 9-3/4" (248 mm) · 10-1/2" (267 mm) · 18-5/8" (473 mm) · 10-7/8" (276 mm) · 11-1/4" (286 mm) · 9-3/4" (248 mm) · 10-7/8" (276 mm)
Page 2 of the Lightolier C6P38MH user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® HID Downlight C6P38MH

Page 1 of 2 6" Aperture, PAR38 Ceramic MH

70W PAR38 FLOOD MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 20134 5 17728 1622 10 12396 15 6288 1901 20 1851 25 460 337 30 140 35 64 47 40 29 45 10 9 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE MEAN CD/SQ M 45 479 55 0 65 0 75 0 85 0

Coefficients of Utilization

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .97 .95 .95 .91 .91 .87 .87 .82 1 .95 .93 .92 .91 .92 .89 .88 .87 .85 .84 .80 2 .92 .90 .88 .86 .89 .86 .86 .84 .84 .82 .79 3 .90 .88 .85 .84 .87 .83 .85 .82 .83 .81 .79 4 .89 .86 .83 .81 .85 .81 .83 .80 .82 .79 .78 5 .87 .84 .81 .79 .83 .79 .82 .78 .80 .78 .76 6 .86 .82 .80 .78 .82 .78 .81 .77 .80 .77 .76 7 .84 .80 .78 .76 .80 .76 .79 .76 .78 .75 .74 8 .83 .79 .77 .75 .78 .75 .78 .75 .77 .74 .73 9 .82 .78 .76 .74 .77 .74 .77 .73 .76 .73 .73 10 .80 .76 .74 .72 .76 .72 .76 .72 .75 .72 .71 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3860 80.42 98.57 0-40 3906 81.39 99.76 0-60 3916 81.59 100 0-90 3916 81.59 100 40-90 9 0.19 0.24 60-90 90-180-180 3916 81.59 100

** EFFICIENCY = 81.6% ** CERTIFIED TEST REPORT NO. 2453FR, DATE: FEB 12, 2004 SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W PAR38 FLOOD MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 26152 5 24195 2202 10 17741 15 9134 2760 20 2934 25 793 544 30 182 35 78 57 40 29 45 4 7 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 221 55 0 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .98 .95 .95 .91 .91 .87 .87 .82 1 .95 .94 .92 .91 .92 .90 .89 .87 .86 .84 .81 2 .93 .90 .89 .87 .89 .86 .86 .84 .84 .82 .80 3 .91 .88 .86 .84 .87 .83 .85 .82 .83 .81 .79 4 .89 .86 .83 .82 .85 .81 .84 .80 .82 .79 .78 5 .87 .84 .81 .79 .83 .79 .82 .78 .81 .78 .76 6 .86 .82 .80 .78 .82 .78 .81 .77 .80 .77 .76 7 .84 .81 .78 .76 .80 .76 .79 .76 .79 .75 .75 8 .83 .79 .77 .75 .78 .75 .78 .75 .77 .74 .73 9 .82 .78 .76 .74 .77 .74 .77 .74 .77 .73 .73 10 .81 .77 .74 .72 .76 .72 .76 .72 .75 .72 .72 LUMINAIRE INPUT WATTS = 110.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 5505 80.97 98.84 0-40 5563 81.82 99.87 0-60 5570 81.92 100 0-90 5570 81.92 100 40-90 7 0.11 0.13 60-90 90-180-180 5570 81.92 100

** EFFICIENCY = 81.9% ** CERTIFIED TEST REPORT NO. 2455FR, DATE: FEB 13, 2004 SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**

70W PAR38 WIDE FLOOD MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 4053 5 3975 378 10 3826 15 3646 1020 20 3278 25 2623 1235 30 2144 35 1451 831 40 248 45 18 55 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 901 55 0 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .87 .85 .85 .81 .81 .78 .78 .73 1 .84 .82 .81 .79 .81 .78 .78 .76 .75 .74 .70 2 .81 .78 .76 .74 .77 .73 .74 .71 .72 .70 .67 3 .78 .74 .71 .69 .73 .69 .71 .67 .70 .66 .64 4 .75 .71 .68 .65 .70 .65 .68 .64 .67 .63 .62 5 .72 .67 .64 .61 .66 .61 .65 .60 .64 .60 .58 6 .69 .64 .61 .58 .64 .58 .63 .58 .62 .57 .56 7 .66 .61 .57 .55 .61 .55 .60 .55 .59 .54 .53 8 .64 .58 .54 .52 .57 .52 .57 .52 .56 .51 .50 9 .61 .55 .52 .49 .55 .49 .54 .49 .54 .49 .48 10 .58 .52 .49 .46 .52 .46 .52 .46 .51 .46 .45 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 5505 80.97 98.84 0-30 2632 54.84 74.81 0-40 3463 72.16 98.43 0-60 3518 73.31 100 0-90 3518 73.31 100 40-90 55 1.15 1.57 60-90 90-180-180 3518 73.31 100

** EFFICIENCY = 73.3% ** CERTIFIED TEST REPORT NO. 2454FR, DATE: FEB 12, 2004 SC = .9 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W PAR38 WIDE FLOOD MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, - CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 7353 5 6975 657 10 6231 15 5506 1553 20 4664 25 3597 1691 30 2759 35 1759 1031 40 288 45 39 74 50 14 55 3 5 60 1 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 1960 55 178 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

WALL 70 50 30 10 50 10 50 10 50 10 0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0 .88 .86 .86 .82 .82 .78 .78 .74 1 .85 .83 .81 .80 .82 .79 .78 .76 .76 .74 .71 2 .81 .79 .77 .74 .77 .74 .75 .72 .73 .71 .68 3 .79 .75 .72 .70 .74 .70 .72 .68 .71 .67 .65 4 .76 .72 .69 .66 .71 .66 .69 .65 .68 .64 .63 5 .73 .68 .65 .62 .68 .62 .66 .62 .65 .61 .60 6 .71 .66 .62 .60 .65 .59 .64 .59 .63 .59 .58 7 .68 .62 .59 .57 .62 .56 .61 .56 .60 .56 .55 8 .65 .60 .56 .54 .59 .54 .59 .54 .58 .53 .52 9 .63 .57 .53 .51 .57 .51 .56 .51 .55 .51 .50 10 .60 .54 .51 .49 .54 .49 .54 .48 .53 .48 .47 LUMINAIRE INPUT WATTS = 110.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3901 57.37 77.85 0-40 4932 72.53 98.43 0-60 5010 73.68 100 0-90 5010 73.69 100 40-90 78 1.16 1.57 60-90 90-180-180 5010 73.69 100

** EFFICIENCY = 73.7% ** CERTIFIED TEST REPORT NO. 2456FR, DATE: FEB 13, SC = .8 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 20 more labels / short text on this page
5,000 · 60° · 10,000 · 15,000 · 20,000 30° · 6,500 · 60° · 13,000 · 19,500 · 26,000 30° · 1,000 · 60° · 2,000 · 3,000 · 4,000 30° · 1,875 · 60° · 3,750 · 5,625 · 7,500 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C6P38MHについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C6P38MHに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C6P38MH 取扱説明書(PDF)

2 ページ·107 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…