JA
Lightolier logo
公式取扱説明書

Lightolier C7CS-P38MH

2 ページ·62 KB·インテリア家具・調度品·PDF·EN
Lightolier C7CS-P38MH
目次 11セクション Calculite ® HID Surface Cylinder C7CS-P38MH · Page 1 of 2 7" Aperture, PAR38 Ceramic Metal Halide Downlight · 37' (940 mm) 4 · Wall Mount Stem Kit Ceiling Mount · … 表示非表示
Page 1 of the Lightolier C7CS-P38MH user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® HID Surface Cylinder C7CS-P38MH

Page 1 of 2 7" Aperture, PAR38 Ceramic Metal Halide Downlight

37' (940 mm) 4

11 1/8" (283 mm) Dia. 8" (203 mm) Dia. 7-3/8" (187 mm) Dia.

Wall Mount Stem Kit Ceiling Mount

Reflector Trim Cylinder Housing Lamp

C7P38MH CL Specular Clear, Minimal Flange CCD Comfort Clear Diffuse, Minimal Flange CCZ Champagne Bronze, Minimal Flange

Ceiling-Mount Wall-Mount C7CS70MHE1 C7CW70MHE1 Electronic 120V 70W PAR38 Ceramic MH C7CS70MHE2 C7CW70MHE2 Electronic 277V 70W PAR38 Ceramic MH C7CS10MHE1 C7CW10MHE1 Electronic 120V 100W PAR38 Ceramic MH C7CS10MHE2 C7CW10MHE2 Electronic 277V 100W PAR38 Ceramic MH C7CS70MHU C7CW70MHU Magnetic 120V/277V 70W PAR38 Ceramic MH C7CS10MHU C7CW10MHU Magnetic 120V/277V 100W PAR38 Ceramic MH

Features 1. Reflector: Low brightness with 45° cut-off to lamp and lamp image. Specular with minimal flange fits precisely into Cylinder housing. 2. Cylinder Housing: White painted seamless aluminum with groove designed to minimize visual appearance. Returned edge precisely seats reflector without visible hardware. 3. Socket: Medium base pulse rated socket with nickel plated screw shell. Special socket design in open rated fixtures accepts only open rated lamps. Snaps onto upper reflector for secure attachment without tools. Unitized con- struction assures proper lamp alignment to optics for consistent performance. 4. Ballast: Electronic or magnetic. Accessible for service and replacement. 5. Back Plate: Cast aluminum, suitable for mounting over 4" octagon outlet box.

Options and Accessories

C4CSWStem Kit: – White (45° Swivel, 37" long) Provide with 5/8” dia. Stem

and 5 1/2” dia. Canopy. Self-aligning swivel provides max. 45° verti- cal tilting. Installs over 4” octagonal outlet box. Stem can be cut to length on site. Auxiliary Lighting: Add suffix A to Cylinder Housing and Reflector Trim.

Labels UL (Suitable For Wet Locations), CSA, I.B.E.W.

Electrical Electronic Ballast: 120V or 277V. Encased, high power factor, T.H.D.

Job Information Type:

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 0.67/0.28 78 100W MH M90/M140 120/277 0.90/0.43 110

Job Name:

Cat. No.:

Magnetic Ballast: 120V/277V dual voltage, 60 Hz., core and coil, HX-HPF circuit type, high power factor, -20° F minimum starting temperature, Type 1 Outdoor rating.

Lamp(s):

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • AO5O4

16-5/8" (422 mm) · 9-1/4" (235 mm)

Page 2 of the Lightolier C7CS-P38MH user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® HID Surface Cylinder C7CS-P38MH

Page 2 of 2 7" Aperture, PAR38 Ceramic Metal Halide Downlight

70W PAR38, FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 22077 5 19279 1769 10 13483 15 7146 2166 20 2784 25 721 513 30 205 35 85 64 40 29 45 1 6 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 59 55 0 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 1.12 1.09 1.09 1.05 1.05 1.00 1.00 .94 1 1.09 1.07 1.06 1.05 1.06 1.03 1.02 1.00 .98 .97 .93 2 1.06 1.04 1.02 1.00 1.02 .99 .99 .96 .97 .94 .91 3 1.04 1.01 .98 .96 1.00 .96 .98 .94 .96 .93 .90 4 1.02 .98 .96 .94 .98 .93 .96 .92 .94 .91 .89 5 1.00 .96 .93 .91 .95 .91 .94 .90 .92 .89 .88 6 .99 .94 .91 .89 .94 .89 .93 .89 .92 .88 .87 7 .97 .92 .89 .87 .92 .87 .91 .87 .90 .86 .85 8 .95 .91 .88 .86 .90 .85 .89 .85 .89 .85 .84 9 .94 .89 .86 .84 .89 .84 .88 .84 .87 .84 .83 10 .92 .87 .85 .83 .87 .83 .87 .83 .86 .82 .82 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 4446 92.65 98.46 0-40 4510 93.97 99.86 0-60 4516 94.1 100 0-90 4516 94.1 100 40-90 6 0.13 0.14 60-90 90-180-180 4516 94.1 100

** EFFICIENCY = 94.1% ** CERTIFIED TEST REPORT NO. 2419FR, DATE: JAN 26, 2004 SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W PAR38, FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMENS 0 28361 5 26181 2386 10 19254 15 10393 3130 20 4124 25 1090 763 30 291 35 120 91 40 47 45 5 11 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 231 55 0 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

WALL 70 50 30 10 50 10 50 10 50 10 0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0 1.12 1.09 1.09 1.04 1.04 1.00 1.00 .94 1 1.09 1.07 1.06 1.04 1.05 1.03 1.01 1.00 .98 .97 .92 2 1.06 1.03 1.01 .99 1.02 .98 .99 .96 .96 .94 .91 3 1.04 1.00 .98 .96 .99 .95 .97 .94 .95 .92 .90 4 1.02 .98 .95 .93 .97 .92 .95 .91 .94 .91 .89 5 1.00 .96 .92 .90 .95 .90 .93 .89 .92 .89 .87 6 .98 .94 .91 .89 .93 .89 .92 .88 .91 .87 .86 7 .96 .92 .89 .87 .91 .86 .90 .86 .89 .86 .85 8 .95 .90 .87 .85 .89 .85 .89 .85 .88 .84 .83 9 .93 .88 .86 .84 .88 .84 .87 .83 .87 .83 .82 10 .92 .87 .84 .82 .87 .82 .86 .82 .86 .82 .81 LUMINAIRE INPUT WATTS = 110.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 6278 92.33 98.41 0-40 6369 93.67 99.83 0-60 6380 93.82 100 0-90 6380 93.82 100 40-90 10 0.16 0.17 60-90 90-180-180 6380 93.82 100

** EFFICIENCY = 93.8% ** CERTIFIED TEST REPORT NO. 2421FR, DATE: JAN 21, 2004 SC = .4 COMPUTED BY LSI PROGRAM **TEST-LITE**

70W PAR38, WIDE FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMS. 0 4860 5 4540 437 10 4365 15 4197 1180 20 3890 25 3162 1498 30 2735 35 1466 929 40 250 45 42 65 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE MEAN CD/SQ M 45 2104 55 0 65 0 75 0 85 0

Coefficients of Utilization

CEILING 80% 70% 50% 30%

WALL 70 50 30 10 50 10 50 10 50 10 0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0 1.02 1.00 1.00 .95 .95 .91 .91 .86 1 .98 .96 .94 .93 .95 .91 .91 .89 .88 .86 .82 2 .94 .91 .89 .86 .90 .85 .87 .83 .85 .82 .79 3 .91 .87 .83 .81 .85 .80 .84 .79 .82 .78 .75 4 .88 .83 .79 .76 .82 .76 .80 .75 .78 .74 .72 5 .84 .79 .74 .72 .78 .71 .76 .71 .75 .70 .68 6 .81 .75 .71 .68 .74 .68 .73 .67 .72 .67 .66 7 .78 .71 .67 .64 .71 .64 .70 .64 .69 .63 .62 8 .75 .68 .64 .61 .67 .61 .67 .61 .66 .60 .59 9 .71 .65 .60 .58 .64 .58 .63 .57 .63 .57 .56 10 .69 .62 .57 .54 .61 .54 .61 .54 .60 .54 .53 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3115 64.9 75.81 0-40 4044 84.26 98.42 0-60 4109 85.61 100 0-90 4109 85.61 100 40-90 64 1.35 1.58 60-90 90-180-180 4109 85.61 100

** EFFICIENCY = 85.6% ** CERTIFIED TEST REPORT NO. 2420FR, DATE: JAN 26, 2004 SC = .9 COMPUTED BY LSI PROGRAM **TEST-LITE**

100W PAR38, WIDE FLOOD, PHILIPS 3K MH LAMP, LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

ANGLE MEAN CP LUMS. 0 7868 5 7495 709 10 6849 15 6228 1761 20 5546 25 4296 2032 30 3425 35 1738 1130 40 296 45 69 84 50 2 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 3439 55 0 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

50 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

0 1.00 .98 .98 .93 .93 .89 .89 .84 1 .97 .95 .93 .91 .93 .90 .89 .87 .86 .85 .81 2 .93 .90 .87 .85 .88 .84 .86 .82 .83 .81 .78 3 .90 .86 .82 .80 .84 .79 .83 .78 .81 .77 .75 4 .87 .82 .78 .76 .81 .75 .79 .74 .78 .74 .72 5 .83 .78 .74 .71 .77 .71 .76 .71 .75 .70 .68 6 .81 .75 .71 .68 .74 .68 .73 .68 .72 .67 .66 7 .77 .71 .68 .65 .71 .64 .70 .64 .69 .64 .63 8 .75 .68 .64 .62 .68 .61 .67 .61 .66 .61 .60 9 .71 .65 .61 .58 .65 .58 .64 .58 .63 .58 .57 10 .69 .62 .58 .56 .62 .56 .61 .55 .61 .55 .54 LUMINAIRE INPUT WATTS = 110.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 4502 66.21 78.74 0-40 5632 82.83 98.51 0-60 5717 84.08 100 0-90 5717 84.08 100 40-90 84 1.25 1.49 60-90 90-180-180 5717 84.08 100

*** EFFICIENCY = 84.1% ** CERTIFIED TEST REPORT NO. 2422FR, SC = .8 DATE: JAN 21, 2004 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • AO5O4
Show 16 more labels / short text on this page
60° · 12,500 · 25,000 30° · 60° · 15,000 · 30,000 30° · 1,250 · 60° · 2,500 · 3,750 · 5,000 30° · 2,000 · 60° · 4,000 · 6,000 · 8,000 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C7CS-P38MHについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C7CS-P38MHに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C7CS-P38MH 取扱説明書(PDF)

2 ページ·62 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…